Acetabular revision in total hip replacement with a press-fit cup

被引:24
|
作者
Elke, R [1 ]
Berli, B [1 ]
Wagner, A [1 ]
Morscher, EW [1 ]
机构
[1] Univ Basel, Orthopaed Dept, CH-4031 Basel, Switzerland
来源
关键词
D O I
10.1302/0301-620X.85B8.13590
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The need for supplementary screw fixation in acetabular revisions is still widely debated. We carried out 439 acetabular revisions over an eight-year period. In 171 hips with contained or small segmental defects, the Morscher press-fit cup was used. These revisions were followed prospectively. No screws were used for additional fixation. A total of 123 hips with a mean follow-up of 7.4 years (5 to 10.5) were available for clinical and radiological review. There was no further revision of a press-fit cup for aseptic loosening. Radiological assessment revealed osteolysis in three hips. Of the original 171 hips there was cranial and medial migration of up to 6 mm at two years in 44 (26%). No further migration was seen after the second post-operative year. Acetabular revision without screws is possible with excellent medium-term results in well selected patients.
引用
收藏
页码:1114 / 1119
页数:6
相关论文
共 50 条
  • [21] Nonmodular flexible press-fit cup in primary total hip arthroplasty - 15-year followup
    Berli, Bernhard J.
    Ping, Gu
    Dick, Walter
    Morscher, Erwin W.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (461) : 114 - 121
  • [22] Does using a polyethylene RM press-fit cup modify the preparation of the acetabulum and acetabular offset in primary hip arthroplasty?
    Erivan, R.
    Aubret, S.
    Villatte, G.
    Mulliez, A.
    Descamps, S.
    Boisgard, S.
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (05) : 669 - 674
  • [23] Extra-large press-fit cups without screws for acetabular revision
    Obenaus, C
    Winkler, H
    Girtler, R
    Huber, M
    Schwägerl, W
    [J]. JOURNAL OF ARTHROPLASTY, 2003, 18 (03): : 271 - 277
  • [24] Monitoring the press-fit insertion of an acetabular cup by impact measurements: Influence of bone abrasion
    Michel, Adrien
    Bosc, Romain
    Mathieu, Vincent
    Hernigou, Philippe
    Haiat, Guillaume
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2014, 228 (10) : 1027 - 1034
  • [25] Advanced material modelling in numerical simulation of primary acetabular press-fit cup stability
    Souffrant, R.
    Zietz, C.
    Fritsche, A.
    Kluess, D.
    Mittelmeier, W.
    Bader, R.
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2012, 15 (08) : 787 - 793
  • [26] Primary stability of a press-fit cup in combination with impaction grafting in an acetabular defect model
    Schierjott, Ronja A.
    Hettich, Georg
    Baxmann, Marc
    Morosato, Federico
    Cristofolini, Luca
    Grupp, Thomas M.
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2021, 39 (05) : 929 - 940
  • [27] PRESS-FIT DESIGN IN TOTAL HIP-REPLACEMENT - A COMPARISON BETWEEN THE LUBINUS AND STANMORE PROSTHESES
    BURGAARD, P
    OLSEN, PA
    JENSEN, NM
    ANDERSEN, PB
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1987, 58 (03): : 326 - 326
  • [28] Global fit concept in revision hip arthroplasty for cementless press-fit femoral stems
    Canovas, F.
    LeBeguec, P.
    Batard, J.
    Gaillard, F.
    Dagneaux, L.
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (04) : 579 - 581
  • [29] IMPROVING THE FIT OF PRESS-FIT HIP STEMS
    ROBERTSON, DD
    WALKER, PS
    HIRANO, SK
    ZHOU, XM
    GRANHOLM, JW
    POSS, R
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1988, (228) : 134 - 140
  • [30] Monobloc press-fit cups with large-diameter bearings are safe in revision total hip arthroplasty
    Synnott, Paul-Andre
    Sivaloganathan, Sivan
    Kiss, Marc-Olivier
    Binette, Benoit
    Morcos, Mina W.
    Vendittoli, Pascal-Andre
    [J]. ORTHOPEDIC REVIEWS, 2022, 14 (04)