Retrospective image-based gating of intracoronary ultrasound images for improved quantitative analysis: The intelligate method

被引:67
|
作者
de Winter, SA [1 ]
Hamers, R [1 ]
Degertekin, M [1 ]
Tanabe, K [1 ]
Lemos, PA [1 ]
Serruys, PW [1 ]
Roelandt, JRTC [1 ]
Bruining, N [1 ]
机构
[1] Erasmus MC, Dept Cardiol, Thoraxctr, NL-3015 GD Rotterdam, Netherlands
关键词
intelligate; imaging; coronary disease; ultrasonics;
D O I
10.1002/ccd.10693
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Quantitative analysis of intracoronary ultrasound (ICUS) studies is performed on a series of tomographic cross-sectional ICUS images acquired during a motorized 0.5 mm/sec catheter pullback. Catheter displacement in the vascular lumen during the cardiac cycle causes an anatomically shuffled ICUS study, which results in a sawtooth-shaped appearance of the coronary segment in longitudinal reconstructed views in quantitative coronary ultrasound software packages. This hampers contour detection and leads to a laborious time-consuming semiquantitative analysis process that may produce inaccurate results. To solve these problems, in the past, online ECG-gated acquisition hardware has been applied. This article describes a novel image-based gating method called Intelligate, which features automatic retrospective selection of end-diastolic frames from videotaped or digitally stored ICUS studies. Our evaluation shows that there are no quantitative differences between analysis results of hardware ECG-gated and Intelligated ICUS studies. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:84 / 94
页数:11
相关论文
共 50 条
  • [21] Image-based cardiac gating for three-dimensional intravascular ultrasound imaging
    Nadkarni, SK
    Boughner, D
    Fenster, A
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (01): : 53 - 63
  • [22] A novel image-based quantitative method for the characterization of NETosis
    Zhao, Wenpu
    Fogg, Darin K.
    Kaplan, Mariana J.
    JOURNAL OF IMMUNOLOGICAL METHODS, 2015, 423 : 104 - 110
  • [23] Image-based Approach to Respiratory Gating for Liver Radiotherapy using a Telerobotic Ultrasound System
    Schlosser, J.
    Salisbury, K.
    Hristov, D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S122 - S122
  • [24] Manifold Learning for Image-Based Breathing Gating with Application to 4D Ultrasound
    Wachinger, Christian
    Yigitsoy, Mehmet
    Navab, Nassir
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2010, PT II,, 2010, 6362 : 26 - 33
  • [25] Image-based registration of ultrasound and magnetic resonance images: A preliminary study
    Pagoulatos, N
    Haynor, DR
    Kim, Y
    MEDICAL IMAGING 2000: IMAGE DISPLAY AND VISUALIZATION, 2000, 3976 : 156 - 164
  • [26] Image-based Co-Registration of Angiography and Intravascular Ultrasound Images
    Wang, Peng
    Ecabert, Olivier
    Chen, Terrence
    Wels, Michael
    Rieber, Johannes
    Ostermeier, Martin
    Comaniciu, Dorin
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (12) : 2238 - 2249
  • [27] Quantitative accuracy of PET for image-based kinetic analysis
    Seo, Youngho
    Teo, Boon-Keng
    Hadi, Mohiuddin
    Schreck, Carole
    Bacharach, Stephen L.
    Hasegawa, Bruce H.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3601 - 3604
  • [28] Image-based method for in-vivo freehand ultrasound calibration
    Wein, Wolfgang
    Khamene, Ali
    MEDICAL IMAGING 2008: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2008, 6920
  • [29] Retrospective cardiac gating for three-dimensional (3D) intravascular ultrasound (IVUS) imaging using an image-based technique
    Nadkarni, S
    Boughner, D
    Fenster, A
    MEDICAL PHYSICS, 2002, 29 (06) : 1198 - 1198
  • [30] IMAGE-BASED LIGHTING ADJUSTMENT METHOD FOR BROWSING OBJECT IMAGES
    Jun Shingu
    Uchihashi, Shingo
    Abe, Tsutomu
    Iyoda, Tetsuo
    Kimber, Don
    Rieffel, Eleanor
    Vaughan, Jim
    ICME: 2009 IEEE INTERNATIONAL CONFERENCE ON MULTIMEDIA AND EXPO, VOLS 1-3, 2009, : 998 - +