Image-based method for in-vivo freehand ultrasound calibration

被引:5
|
作者
Wein, Wolfgang [1 ]
Khamene, Ali [1 ]
机构
[1] Siemens Corp Res, Imaging & Visualizat Dept, Princeton, NJ USA
关键词
3D freehand ultrasound; calibration; reconstruction;
D O I
10.1117/12.769948
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
For freehand ultrasound systems, a calibration method is necessary to locate the position and orientation of a 2D B-mode ultrasound image plane with respect to a position sensor attached to the transducer. In addition, the acquisition time discrepancy between the position measurements and the image frames has the be computed. We developed a new method that adresses both of these problems, based on the fact that a freehand ultrasound system establishes consistent 3D data of an arbitrary object. Two angulated sweeps of any object containing well visible structures are recorded, each at a different orientation. A non-linear optimization strategy maximizes the similarity of 2D ultrasound images from one sweep to reconstructions computed from the other sweep. No designated phantom is required for this calibration. The process can be performed in vivo on the patient. We evaluated our method using freehand acquisitions on both a phantom and the human liver. The accuracy of the approach was validated using a 3D ultrasound probe as a known reference geometry.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Using image-based regression to acquire freehand 3D ultrasound
    Prager, RW
    Gee, AH
    Treece, GM
    Cash, CJC
    Berman, LH
    2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 970 - 973
  • [2] Statistics analysis of calibration precision for freehand ultrasound image
    Rao, Y., 2013, CESER Publications, Post Box No. 113, Roorkee, 247667, India (47):
  • [3] 3-D Calibration algorithm for freehand ultrasound image
    Peng, Y., 1600, Asian Network for Scientific Information (12):
  • [4] Calibration algorithm for freehand ultrasound
    Rao, Yao
    Peng, Yao
    Journal of Theoretical and Applied Information Technology, 2012, 45 (02) : 688 - 693
  • [5] Breast intraoperative electron radiotherapy: Image-based setup verification and in-vivo dosimetry
    Baghani, Hamid Reza
    Robatjazi, Mostafa
    Mahdavi, Seied Rabi
    Nafissi, Nahid
    Akbari, Mohammad Esmail
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 60 : 37 - 43
  • [6] Image-based calibration for micro manipulators
    Li, GY
    Xi, N
    INTERNATIONAL JOURNAL OF NONLINEAR SCIENCES AND NUMERICAL SIMULATION, 2002, 3 (3-4) : 437 - 444
  • [7] Image-based method for estimation of global calibration factor for SPECT images
    Halty, A.
    Badel, J. N.
    Kryza, D.
    Giraudet, A. L.
    Sarrut, D.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S515 - S515
  • [8] An image registration approach to automated calibration for freehand 3D ultrasound
    Blackall, JM
    Rueckert, D
    Maurer, CR
    Penney, GP
    Hill, DLG
    Hawkes, DJ
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2000, 2000, 1935 : 462 - 471
  • [9] Temporal calibration of freehand three-dimensional ultrasound using image alignment
    Gooding, MJ
    Kennedy, SH
    Noble, JA
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (07): : 919 - 927
  • [10] Robust and automatic calibration method for 3D freehand ultrasound
    Rousseau, F
    Hellier, P
    Barillot, C
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2003, PT 2, 2003, 2879 : 440 - 448