Progressive attenuation fields: Fast 2D-3D image registration without precomputation

被引:38
|
作者
Rohlfing, T
Russakoff, DB
Denzler, J
Mori, K
Maurer, CR
机构
[1] SRI Int, Program Neurosci, Menlo Pk, CA 94025 USA
[2] Stanford Univ, Dept Comp Sci, Stanford, CA 94305 USA
[3] Univ Jena, Chair Comp Vis, D-07737 Jena, Germany
[4] Nagoya Univ, Dept Media Sci, Grad Sch Informat Sci, Nagoya, Aichi 46401, Japan
[5] Stanford Univ, Dept Neurosurg, Stanford, CA 94305 USA
关键词
2D-3D image registration; digitally reconstructed radiograph (DRR); attenuation field; precomputation; computational performance;
D O I
10.1118/1.1997367
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Computation of digitally reconstructed radiograph (DRR) images is the rate-limiting step in most current intensity-based algorithms for the registration of three-dimensional (3D) images to two-dimensional (2D) projection images. This paper introduces and evaluates the progressive attenuation field (PAF), which is a new method to speed up DRR computation. A PAF is closely related to an attenuation field (AF). A major difference is that a PAF is constructed on the fly as the registration proceeds; it does not require any precomputation time, nor does it make any prior assumptions of the patient pose or limit the permissible range of patient motion. A PAF effectively acts as a cache memory for projection values once they are computed, rather than as a lookup table for precomputed projections like standard AFs. We use a cylindrical attenuation field parametrization, which is better suited for many medical applications of 2D-3D registration than the usual two-plane parametrization. The computed attenuation values are stored in a hash table for time-efficient storage and access. Using clinical gold-standard spine image data sets from five patients, we demonstrate consistent speedups of intensity-based 2D-3D image registration using PAF DRRs by a factor of 10 over conventional ray casting DRRs with no decrease of registration accuracy or robustness. (C) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:2870 / 2880
页数:11
相关论文
共 50 条
  • [21] A New Multi-Modal Similarity Measure for Fast Gradient-Based 2D-3D Image Registration
    Pickering, Mark R.
    Muhit, Abdullah A.
    Searvell, Jennie M.
    Smith, Paul N.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 5821 - +
  • [22] Efficient framework for deformable 2D-3D registration
    Fluck, Oliver
    Aharon, Shmuel
    Khamene, Ali
    MEDICAL IMAGING 2008: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, PTS 1 AND 2, 2008, 6918
  • [23] Effective 2D-3D Medical Image Registration using Support Vector Machine
    Qi, Wenyan
    Gu, Lixu
    Zhao, Qiang
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 5386 - +
  • [24] Increasing the Automation of a 2D-3D Registration System
    Varnavas, Andreas
    Carrell, Tom
    Penney, Graeme
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (02) : 387 - 399
  • [25] OpenGL based 2D-3D registration of a CT image dataset with OBI images
    Choi, B.
    Balter, P.
    Dong, L.
    Mohan, R.
    Starkschall, G.
    MEDICAL PHYSICS, 2006, 33 (06) : 2161 - 2161
  • [26] A Neural Network Based Registration Quality Evaluator for 2D-3D Image Registrations
    Wu, J.
    Murphy, M.
    Samant, S.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [27] 2D-3D Registration using Intensity Gradients
    Duraisamy, Prakash
    Belkhouche, Yassine
    Jackson, Stephen
    Namuduri, Kamesh
    Buckles, Bill
    SIGNAL AND DATA PROCESSING OF SMALL TARGETS 2011, 2011, 8137
  • [28] Fully automated 2D-3D registration and verification
    Varnavas, Andreas
    Carrell, Tom
    Penney, Graeme
    MEDICAL IMAGE ANALYSIS, 2015, 26 (01) : 108 - 119
  • [29] 2D-3D registration based on shape matching
    Cyr, CM
    Kamal, AF
    Sebastian, TB
    Kimia, BB
    IEEE WORKSHOP ON MATHEMATICAL METHODS IN BIOMEDICAL IMAGE ANALYSIS, PROCEEDINGS, 2000, : 198 - 203
  • [30] Image-based RSA: Roentgen stereophotogrammetric analysis based on 2D-3D image registration
    de Bruin, P. W.
    Kaptein, B. L.
    Stoel, B. C.
    Reiber, J. H. C.
    Rozing, P. M.
    Valstar, E. R.
    JOURNAL OF BIOMECHANICS, 2008, 41 (01) : 155 - 164