2D-3D Registration using Intensity Gradients

被引:0
|
作者
Duraisamy, Prakash [1 ]
Belkhouche, Yassine [1 ]
Jackson, Stephen [2 ]
Namuduri, Kamesh [3 ]
Buckles, Bill [1 ]
机构
[1] Univ N Texas, Dept Comp Sci & Engn, Denton, TX 76203 USA
[2] Univ N Texas, Dept Math, Denton, TX 76203 USA
[3] Univ N Texas, Dept Elect Engn, Denton, TX 76203 USA
关键词
camera; lidr; calibration; registration; intensity;
D O I
10.1117/12.894288
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This papers explores the use of an error metric based on intensity gradients in an automatic camera pose recovery method for 2D-3D image registration. The method involves extraction of lines from the 3D image and then uses intensity gradients to register these onto the 2D image. This approach have overcome the limitations of matching the features to register the 2D-3D images. The goal of our algorithm is to estimate pose parameters without any apriori knowledge (GPS) and in less processing time. We demonstrated the validity of our approach by experimenting on perspective view using lines as feature.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Multilevel 2D-3D Intensity-Based Image Registration
    Lange, Annkristin
    Heldmann, Stefan
    [J]. BIOMEDICAL IMAGE REGISTRATION (WBIR 2020), 2020, 12120 : 57 - 66
  • [2] Evaluation of a stochastic approach to 2D-3D intensity-based registration
    Aouadi, S.
    Sarry, L.
    [J]. 2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 6388 - 6391
  • [3] A robust technique for 2D-3D registration
    Gong, Ren Hui
    Abolinaesumi, Purang
    Stewart, James
    [J]. 2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 714 - 717
  • [4] Standardized evaluation of 2D-3D registration
    van de Kraats, EB
    Penney, GP
    Tomazevic, D
    van Walsum, T
    Niessen, WJ
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2004, PT 1, PROCEEDINGS, 2004, 3216 : 574 - 581
  • [5] 2D-3D Registration of Cardiac Images Using Catheter Constraints
    Truong, M. V. N.
    Aslam, A.
    Ginks, M.
    Rinaldi, C. A.
    Rezavi, R.
    Penney, G. P.
    Rhode, K. S.
    [J]. CINC: 2009 36TH ANNUAL COMPUTERS IN CARDIOLOGY CONFERENCE, 2009, 36 : 605 - +
  • [6] Accurate and precise 2D-3D registration based on X-ray intensity
    Aouadi, Souha
    Sarry, Laurent
    [J]. COMPUTER VISION AND IMAGE UNDERSTANDING, 2008, 110 (01) : 134 - 151
  • [7] Intensity-based 2D-3D registration for an ACL reconstruction navigation system
    Guo, Na
    Yang, Biao
    Ji, Xuquan
    Wang, Yuhan
    Hu, Lei
    Wang, Tianmiao
    [J]. INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2019, 15 (04):
  • [8] Markov Random Field Optimization for Intensity-based 2D-3D Registration
    Zikic, Darko
    Glocker, Ben
    Kutter, Oliver
    Groher, Martin
    Komodakis, Nikos
    Khamene, Ali
    Paragios, Nikos
    Navab, Nassir
    [J]. MEDICAL IMAGING 2010: IMAGE PROCESSING, 2010, 7623
  • [9] Fast intensity-based 2D-3D image registration of clinical data using light fields
    Russakoff, DB
    Rohlfing, T
    Maurer, CR
    [J]. NINTH IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION, VOLS I AND II, PROCEEDINGS, 2003, : 416 - 422
  • [10] Efficient framework for deformable 2D-3D registration
    Fluck, Oliver
    Aharon, Shmuel
    Khamene, Ali
    [J]. MEDICAL IMAGING 2008: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, PTS 1 AND 2, 2008, 6918