Kidney Perfusion in Contrast-Enhanced Ultrasound (CEUS) Correlates with Renal Function in Living Kidney Donors

被引:11
|
作者
El-Bandar, Nasrin [1 ,2 ,3 ,4 ]
Lerchbaumer, Markus H. [2 ,3 ,4 ,5 ]
Peters, Robert [1 ,2 ,3 ,4 ]
Maxeiner, Andreas [1 ,2 ,3 ,4 ]
Kotsch, Katja [2 ,3 ,4 ,6 ]
Sattler, Arne [2 ,3 ,4 ,6 ]
Miller, Kurt [1 ,2 ,3 ,4 ]
Schlomm, Thorsten [1 ,2 ,3 ,4 ]
Hamm, Bernd [2 ,3 ,4 ,5 ]
Budde, Klemens [2 ,3 ,4 ,7 ]
Liefeldt, Lutz [2 ,3 ,4 ,7 ]
Fischer, Thomas [2 ,3 ,4 ,5 ]
Friedersdorff, Frank [1 ,2 ,3 ,4 ,8 ]
机构
[1] Charite Univ Med Berlin, Dept Urol, D-10117 Berlin, Germany
[2] Free Univ Berlin, D-10117 Berlin, Germany
[3] Humboldt Univ, D-10117 Berlin, Germany
[4] Berlin Inst Hlth, D-10117 Berlin, Germany
[5] Charite Univ Med Berlin, Dept Radiol, D-10117 Berlin, Germany
[6] Charite Univ Med Berlin, Dept Gen Visceral & Vasc Surg, D-10117 Berlin, Germany
[7] Charite Univ Med Berlin, Dept Nephrol & Internal Intens Care Med, D-10117 Berlin, Germany
[8] Evangel Krankenhaus Konigin Elisabeth Herzberge, Dept Urol, D-10365 Berlin, Germany
关键词
Contrast-enhanced ultrasound; kidney perfusion; kidney function; kidney transplantation; kidney donation; GLOMERULAR-FILTRATION-RATE; CLINICAL-PRACTICE; CREATININE; SONOGRAPHY; PREDICTION; GUIDELINES; CLEARANCE; EQUATION; VOLUME; CARE;
D O I
10.3390/jcm11030791
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Contrast-enhanced ultrasound (CEUS) is a widely used diagnostic tool for analyzing perfusion and characterizing lesions in several organs. However, to date, it has not been sufficiently investigated whether there is an association between CEUS findings and kidney function. This study aimed at identifying the potential relationship between kidney function and the renal perfusion status determined by CEUS in living kidney donors. A total of 30 living kidney donors examined between April 2018 and March 2020 were included in the study. All patients underwent various diagnostic procedures for evaluation of renal function. CEUS was performed in all 30 donors one day before nephrectomy. Kidney perfusion was quantified using a postprocessing tool (VueBox, Bracco Imaging). Various perfusion parameters were subsequently analyzed and compared with the results of the other methods used to evaluate kidney function. Of all parameters, mean signal intensity (MeanLin) had the strongest correlation, showing significant correlations with eGFR (CG) (r = -0.345; p = 0.007) and total kidney volume (r = -0.409; p = 0.001). While there was no significant correlation between any perfusion parameter and diethylenetriaminepentaacetic acid (DTPA), we detected a significant correlation between MeanLin and DTPA (r = -0.502; p = 0.005) in the subgroup of normal-weight donors. The results indicate that signal intensity in CEUS is associated with kidney function in normal-weight individuals. Body mass index (BMI) may be a potential confounder of signal intensity in CEUS. Thus, more research is needed to confirm these results in larger study populations.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Contrast-Enhanced Ultrasound (CEUS) of Pancreatic Cancer
    D’Onofrio M.
    Ciaravino V.
    Crosara S.
    De Robertis R.
    Pozzi Mucelli R.
    Current Radiology Reports, 3 (3)
  • [42] CONTRAST-ENHANCED ULTRASOUND TO ASSESS RENAL MICROCIRCULATION IN PATIENTS WITH CHRONIC KIDNEY DISEASE
    Garessus, Jonas
    Brito, Wendy
    Loncle, Nicolas
    Vannelli, Anna
    Wuerzner, Gregoire
    Schneider, Antoine
    Pruijm, Menno
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2020, 35 : 998 - 998
  • [43] Contrast-enhanced ultrasound (CEUS) in abdominal intervention
    Huang, Dean Y.
    Yusuf, Gibran T.
    Daneshi, Mohammad
    Ramnarine, Raymond
    Deganello, Annamaria
    Sellars, Maria E.
    Sidhu, Paul S.
    ABDOMINAL RADIOLOGY, 2018, 43 (04) : 960 - 976
  • [44] High-Framerate Dynamic Contrast-Enhanced Ultrasound Imaging of Rat Kidney Perfusion
    Le, David Q.
    Chang, Emily
    Dayton, Paul A.
    Johnson, Kennita
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 1326 - 1329
  • [45] The prevalence and significance of renal perfusion defects in early kidney transplants quantified using 3D contrast enhanced ultrasound (CEUS)
    Ben Stenberg
    Wilkinson, M.
    Elliott, S.
    Caplan, N.
    EUROPEAN RADIOLOGY, 2017, 27 (11) : 4525 - 4531
  • [46] The prevalence and significance of renal perfusion defects in early kidney transplants quantified using 3D contrast enhanced ultrasound (CEUS)
    Ben Stenberg
    M. Wilkinson
    S. Elliott
    N. Caplan
    European Radiology, 2017, 27 : 4525 - 4531
  • [47] Effect of iodinated contrast media on renal perfusion: A randomized comparison study in pigs using quantitative contrast-enhanced ultrasound (CEUS)
    Philipp Lamby
    Friedrich Jung
    Stefanie Graf
    Lotte Schellenberg
    Johannes Falter
    Natascha Platz-da-Silva
    Stephan Schreml
    Lukas Prantl
    Ralf P. Franke
    Ernst M. Jung
    Scientific Reports, 7
  • [48] CONTRAST-ENHANCED ULTRASOUND IN THE EVALUATION OF EARLY KIDNEY GRAFT FUNCTION: A PILOT STUDY
    Elec, Florin
    Elec, Alina
    Bolboaca, Sorana
    Muntean, Adriana
    Socaciu, Mihai
    Iacob, Gheorghita
    Zaro, Razvan
    Andries, Alexandra
    Contis, Ramona
    Ignat, Radu
    Badea, Radu
    TRANSPLANT INTERNATIONAL, 2019, 32 : 210 - 210
  • [49] The Usefulness of Contrast-Enhanced Ultrasound in the Assessment of Early Kidney Transplant Function and Complications
    Alvarez Rodriguez, Sara
    Hevia Palacios, Vital
    Sanz Mayayo, Enrique
    Gomez Dos Santos, Victoria
    Diez Nicolas, Victor
    Sanchez Gallego, Maria Dolores
    Lorca Alvaro, Javier
    Burgos Revilla, Francisco Javier
    DIAGNOSTICS, 2017, 7 (03):
  • [50] Effect of iodinated contrast media on renal perfusion: A randomized comparison study in pigs using quantitative contrast-enhanced ultrasound (CEUS)
    Lamby, Philipp
    Jung, Friedrich
    Graf, Stefanie
    Schellenberg, Lotte
    Falter, Johannes
    Platz-da-Silva, Natascha
    Schreml, Stephan
    Prantl, Lukas
    Franke, Ralf P.
    Jung, Ernst M.
    SCIENTIFIC REPORTS, 2017, 7