Kidney Perfusion in Contrast-Enhanced Ultrasound (CEUS) Correlates with Renal Function in Living Kidney Donors

被引:11
|
作者
El-Bandar, Nasrin [1 ,2 ,3 ,4 ]
Lerchbaumer, Markus H. [2 ,3 ,4 ,5 ]
Peters, Robert [1 ,2 ,3 ,4 ]
Maxeiner, Andreas [1 ,2 ,3 ,4 ]
Kotsch, Katja [2 ,3 ,4 ,6 ]
Sattler, Arne [2 ,3 ,4 ,6 ]
Miller, Kurt [1 ,2 ,3 ,4 ]
Schlomm, Thorsten [1 ,2 ,3 ,4 ]
Hamm, Bernd [2 ,3 ,4 ,5 ]
Budde, Klemens [2 ,3 ,4 ,7 ]
Liefeldt, Lutz [2 ,3 ,4 ,7 ]
Fischer, Thomas [2 ,3 ,4 ,5 ]
Friedersdorff, Frank [1 ,2 ,3 ,4 ,8 ]
机构
[1] Charite Univ Med Berlin, Dept Urol, D-10117 Berlin, Germany
[2] Free Univ Berlin, D-10117 Berlin, Germany
[3] Humboldt Univ, D-10117 Berlin, Germany
[4] Berlin Inst Hlth, D-10117 Berlin, Germany
[5] Charite Univ Med Berlin, Dept Radiol, D-10117 Berlin, Germany
[6] Charite Univ Med Berlin, Dept Gen Visceral & Vasc Surg, D-10117 Berlin, Germany
[7] Charite Univ Med Berlin, Dept Nephrol & Internal Intens Care Med, D-10117 Berlin, Germany
[8] Evangel Krankenhaus Konigin Elisabeth Herzberge, Dept Urol, D-10365 Berlin, Germany
关键词
Contrast-enhanced ultrasound; kidney perfusion; kidney function; kidney transplantation; kidney donation; GLOMERULAR-FILTRATION-RATE; CLINICAL-PRACTICE; CREATININE; SONOGRAPHY; PREDICTION; GUIDELINES; CLEARANCE; EQUATION; VOLUME; CARE;
D O I
10.3390/jcm11030791
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Contrast-enhanced ultrasound (CEUS) is a widely used diagnostic tool for analyzing perfusion and characterizing lesions in several organs. However, to date, it has not been sufficiently investigated whether there is an association between CEUS findings and kidney function. This study aimed at identifying the potential relationship between kidney function and the renal perfusion status determined by CEUS in living kidney donors. A total of 30 living kidney donors examined between April 2018 and March 2020 were included in the study. All patients underwent various diagnostic procedures for evaluation of renal function. CEUS was performed in all 30 donors one day before nephrectomy. Kidney perfusion was quantified using a postprocessing tool (VueBox, Bracco Imaging). Various perfusion parameters were subsequently analyzed and compared with the results of the other methods used to evaluate kidney function. Of all parameters, mean signal intensity (MeanLin) had the strongest correlation, showing significant correlations with eGFR (CG) (r = -0.345; p = 0.007) and total kidney volume (r = -0.409; p = 0.001). While there was no significant correlation between any perfusion parameter and diethylenetriaminepentaacetic acid (DTPA), we detected a significant correlation between MeanLin and DTPA (r = -0.502; p = 0.005) in the subgroup of normal-weight donors. The results indicate that signal intensity in CEUS is associated with kidney function in normal-weight individuals. Body mass index (BMI) may be a potential confounder of signal intensity in CEUS. Thus, more research is needed to confirm these results in larger study populations.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Contrast-enhanced ultrasound with SonoVue could accurately assess the renal microvascular perfusion in diabetic kidney damage
    Ma, Fang
    Cang, Yanqin
    Zhao, Baozhen
    Liu, Yuanyuan
    Wang, Chaoqing
    Liu, Bo
    Wu, Tianfu
    Song, Yaxiang
    Peng, Ai
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2012, 27 (07) : 2891 - 2898
  • [22] INDICATIONS AND POSSIBILITIES FOR CONTRAST-ENHANCED ULTRASOUND (CEUS) IN KIDNEY TRANSPLANT RECIPIENTS: A SINGLE CENTER EXPERIENCE
    Putz, F. J.
    Haneder, E.
    Erlmeier, A.
    Banas, M.
    Jung, E. M.
    Banas, B.
    TRANSPLANT INTERNATIONAL, 2018, 31 : 24 - 24
  • [23] INDICATIONS AND POSSIBILITIES FOR CONTRAST-ENHANCED ULTRASOUND (CEUS) IN KIDNEY TRANSPLANT RECIPIENTS: A SINGLE CENTER EXPERIENCE
    Putz, Franz Josef
    Haneder, Eva
    Banas, Miriam
    Jung, Ernst Michael
    Banas, Bernhard
    TRANSPLANT INTERNATIONAL, 2019, 32 : 85 - 85
  • [24] Application of contrast-enhanced ultrasound (CEUS) in the evaluation of kidney wound healing after partial nephrectomy
    Yang, Cheng
    Niu, Di
    Liang, Chaozhao
    Li, Liang
    INTERNATIONAL JOURNAL OF UROLOGY, 2020, 27 : 129 - 129
  • [25] Ultrasound Doppler Flow Parameters Are Independently Associated with Renal Cortex Contrast-Enhanced Multidetector Computed Tomography Perfusion and Kidney Function
    Lubas, Arkadiusz
    Zegadlo, Arkadiusz
    Frankowska, Emilia
    Klimkiewicz, Jakub
    Jedrych, Ewelina
    Niemczyk, Stanislaw
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (06)
  • [26] Simplified approach for the assessment of kidney perfusion and acute kidney injury at the bedside using contrast-enhanced ultrasound
    Ivan Göcze
    Philipp Renner
    Bernhard M. Graf
    Hans J. Schlitt
    Thomas Bein
    Karin Pfister
    Intensive Care Medicine, 2015, 41 : 362 - 363
  • [27] Simplified approach for the assessment of kidney perfusion and acute kidney injury at the bedside using contrast-enhanced ultrasound
    Goecze, Ivan
    Renner, Philipp
    Graf, Bernhard M.
    Schlitt, Hans J.
    Bein, Thomas
    Pfister, Karin
    INTENSIVE CARE MEDICINE, 2015, 41 (02) : 362 - 363
  • [28] The clinical use of contrast-enhanced ultrasound in the kidney
    Tenant, Sean C.
    Gutteridge, Catherine M.
    ULTRASOUND, 2016, 24 (02) : 94 - 103
  • [29] Contrast-enhanced MRI for simultaneous evaluation of renal morphology and split renal function in living kidney donor candidates
    Krumm, Patrick
    Hupka, Tanja
    Haussmann, Florian
    Dittmann, Helmut
    Muehlbacher, Thomas
    Nadalin, Silvio
    Koenigsrainer, Alfred
    Nikolaou, Konstantin
    Heyne, Nils
    Kramer, Ulrich
    Guthoff, Martina
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 142
  • [30] Contrast-enhanced ultrasound (CEUS) of cystic and solid renal lesions: a review
    Mittul Gulati
    Kevin G. King
    Inderbir S. Gill
    Vivian Pham
    Edward Grant
    Vinay A. Duddalwar
    Abdominal Imaging, 2015, 40 : 1982 - 1996