An update of second law analysis and optimization of a single-flash geothermal power plant in Dieng, Indonesia

被引:13
|
作者
Rudiyanto, Bayu [1 ]
Bahthiyar, Muhamad Aries [2 ]
Pambudi, Nugroho Agung [3 ]
Widjonarko [4 ]
Hijriawan, Miftah [5 ]
机构
[1] Politekn Negeri Jember, Dept Renewable Energy Engn, Energy Engn Lab, Jember 68121, Indonesia
[2] Politekn Negeri Jember, Grad Sch Dept Renewable Energy Engn, Jember 68121, Indonesia
[3] Univ Sebelas Maret, Energy Soc & Lab Mech Engn Educ, Jl Ir Sutami 36A, Surakarta 57126, Indonesia
[4] Univ Jember, Dept Elect Engn, Jl Kalimantan 37 Kampus Tegalboto, Jember 68121, Indonesia
[5] Univ Sebelas Maret, Grad Programme Mech Engn, Jl Ir Sutami 36A, Surakarta 57126, Indonesia
关键词
Thermodynamic; Single-flash; Exergy; Power plant; Optimization; EXERGETIC ANALYSIS; PERFORMANCE;
D O I
10.1016/j.geothermics.2021.102212
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Dieng geothermal power plant is one of the Geothermal plants located in Indonesia with a total estimated potential of 400 MWe. The reservoir is characterized by water-dominated with 240 to 333 degrees C temperature. Recently, the company operated one unit of single-flash system with a capacity of 60 MW. To improve its capacity, unit expansion of unit 2 and 3 are designed with each capacity of 60 MW. Apart from this expansion, another effort is optimizing the existing plant. It can be conducted with a thermodynamic approach using energy and exergy analysis. Therefore, this study aims to evaluate and optimize the existing geothermal power plant using energy and exergy analysis. With the latest data obtained, the results show that the exergy value of production wells is around 106,515 kW. The electricity production with the system is around 40,680 kW, resulting in an exergy efficiency of about 38.19%. Furthermore, the optimization is carried out on the turbine because it shows the greatest irreversibility of 11,217 kW. Optimization is done by varying the incoming turbine pressure. These results indicate that higher inlet pressure increases irreversibility and lowers energy efficiency. Furthermore, the optimum inlet turbine pressure is achieved at 5.5 bar with the maximum change depending on the ambient temperature.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Exergoeconomic analysis and multi-objective optimization of a novel combined flash-binary cycle for Sabalan geothermal power plant in Iran
    Aali, A.
    Pourmahmoud, N.
    Zare, V.
    ENERGY CONVERSION AND MANAGEMENT, 2017, 143 : 377 - 390
  • [42] Thermodynamic analysis and optimization of an ORC hybrid geothermal-solar power plant
    Maali, Rafika
    Khir, Tahar
    EURO-MEDITERRANEAN JOURNAL FOR ENVIRONMENTAL INTEGRATION, 2023, 8 (02) : 341 - 352
  • [43] Performance optimization and improvement of a flash-binary geothermal power plant using zeotropic mixtures with PSO algorithm
    Kolahi, Mohammad-Reza
    Nemati, Arash
    Yari, Mortaza
    GEOTHERMICS, 2018, 74 : 45 - 56
  • [44] SECOND LAW AND SENSITIVITY ANALYSIS OF A COMBINED CYCLE POWER PLANT IN TURKEY
    Yilmazoglu, Mustafa Zeki
    Amirabedin, Ehsan
    ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2011, 31 (02) : 41 - 50
  • [45] Geothermal double-flash plant with interstage reheating: An updated and expanded thermal and exergetic analysis and optimization
    DiPippo, Ronald
    GEOTHERMICS, 2013, 48 : 121 - 131
  • [46] Comparative Analysis of Electric Power and Steam Loss Rate between Single Flash and Binary Geothermal Power System with Single Screw Expander
    Wang, Jingfu
    Zhang, Yong
    Wang, Wei
    Zhang, Yongzhi
    PROGRESS IN POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2012, 354-355 : 325 - 328
  • [47] Optimization of a Single Flash Geothermal Power Plant Powered by a Trans-Critical Carbon Dioxide Cycle Using Genetic Algorithm and Nelder-Mead Simplex Method
    Aryanfar Y.
    Alcaraz J.L.G.
    Energy Engineering: Journal of the Association of Energy Engineering, 2023, 120 (02): : 263 - 275
  • [48] Energy, exergy, economic and exergoenvironmental analyses of transcritical CO2 cycle powered by single flash geothermal power plant
    Assad, Mamdouh El Haj
    Aryanfar, Yashar
    Javaherian, Amirreza
    Khosravi, Ali
    Aghaei, Karim
    Hosseinzadeh, Siamak
    Pabon, Juan
    Mahmoudi, S. M. S.
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2021, 16 (04) : 1504 - 1518
  • [49] SECOND-LAW ANALYSIS IN A STEAM POWER PLANT FOR MINIMIZATION OF AVOIDABLE EXERGY DESTRUCTION
    Ray, Tapan K.
    Ekbote, Pankaj
    Ganguly, Ranjan
    Gupta, Amitava
    ES2010: PROCEEDINGS OF ASME 4TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, VOL 1, 2010, : 859 - 868
  • [50] Modeling and design of the new combined double-flash and binary geothermal power plant for multigeneration purposes; thermodynamic analysis
    Yilmaz, Fatih
    Ozturk, Murat
    Selbas, Resat
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2022, 47 (45) : 19381 - 19396