Thermodynamic analysis and optimization of an ORC hybrid geothermal-solar power plant

被引:3
|
作者
Maali, Rafika [1 ]
Khir, Tahar [1 ]
机构
[1] Univ Gabes, Natl Engn Sch Gabes, Res Lab Appl Thermodynam LR18ES33, Gabes 6029, Tunisia
关键词
Energy analysis; Exergy optimization; Geothermal energy; Organic Rankine cycle; Southern Tunisia; Solar energy; ORGANIC RANKINE-CYCLE; ENERGY; HEAT; TUNISIA; DESIGN;
D O I
10.1007/s41207-023-00359-1
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Energy and exergy analysis is conducted on a hybrid (solar-geothermal) organic Rankine cycle (ORC) power plant. The proposed system is designed to be installed in southern Tunisia. Energy and exergy balances are established for the different components of the power plant. A parametric study is conducted to analyze the effects of the main operating parameters on the hybrid power plant performance during two typical days in summer and winter. Energy and exergy efficiency as well as the influence coefficient are selected as performance criteria for the power plant. The results obtained show that the main source of irreversibility is the steam generator, followed by the air-cooled condenser and the turbine. The highest influence coefficients are obtained for the steam generator and the turbine. The lowest exergy efficiency is obtained for the steam generator. Results show that the volume flow rate and the inlet temperature of the heat transfer fluid affect the power plant performance. Linear regression analysis is applied to establish the relationship between these two operating parameters and the solar radiation in order to optimize the power plant performance. This optimization procedure permits the exergy efficiency to be improved by 10.35 and 6% in the winter and summer, respectively. The results also indicate that as the geothermal water temperature increases in the range of 55-75 degrees C, the overall exergy efficiency increases by about 4.35% in winter. In summer, the geothermal water temperature does not significantly affect the overall power plant exergy efficiency. The overall exergy efficiency increases from 41 to 53% when the condensation pressure decreases from 2 bar to 1 bar.
引用
收藏
页码:341 / 352
页数:12
相关论文
共 50 条
  • [1] Thermodynamic analysis and optimization of an ORC hybrid geothermal–solar power plant
    Rafika Maali
    Tahar Khir
    Euro-Mediterranean Journal for Environmental Integration, 2023, 8 : 341 - 352
  • [2] Conventional and Advanced Exergy-Based Analysis of Hybrid Geothermal-Solar Power Plant Based on ORC Cycle
    Alibaba, Massomeh
    Pourdarbani, Razieh
    Manesh, Mohammad Hasan Khoshgoftar
    Herrera-Miranda, Israel
    Gallardo-Bernal, Ivan
    Hernandez-Hernandez, Jose Luis
    APPLIED SCIENCES-BASEL, 2020, 10 (15):
  • [3] Thermodynamic, exergo-economic and exergo-environmental analysis of hybrid geothermal-solar power plant based on ORC cycle using emergy concept
    Alibaba, Massomeh
    Pourdarbani, Razieh
    Manesh, Mohammad Hasan Khoshgoftar
    Ochoa, Guillermo Valencia
    Forero, Jorge Duarte
    HELIYON, 2020, 6 (04)
  • [4] A Geothermal-Solar Hybrid Power Plant with Thermal Energy Storage
    Bokelman, Brady
    Michaelides, Efstathios E.
    Michaelides, Dimitrios N.
    ENERGIES, 2020, 13 (05)
  • [5] Thermodynamic analysis of a geothermal-solar flash-binary hybrid power generation system
    Wan, Peipei
    Gong, Liang
    Bai, Zhang
    INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 3 - 8
  • [6] NUMERICAL ANALYSIS OF GEOTHERMAL HEAT EXCHANGERS TO BE IMPLEMENTED IN A GEOTHERMAL-SOLAR HYBRID POWER PLANT FOR ELECTRICITY PRODUCTION IN MEXICO
    Rangel Arista, Jorge A.
    Pacheco Ibarra, J. Jesus
    Rubio-Maya, Carlos
    Gonzalez Pedraza, Oskar J.
    Alcantar Martinez, Daniel
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2016, VOL. 6B, 2017,
  • [7] Performance Analysis and Optimization of a Hybrid Solar Geothermal Power Plant
    Maali, Rafika
    Khir, Tahar
    Ben Brahim, Ammar
    RECENT ADVANCES IN ENVIRONMENTAL SCIENCE FROM THE EURO-MEDITERRANEAN AND SURROUNDING REGIONS, VOLS I AND II, 2018, : 1581 - 1584
  • [8] Thermodynamic performance evaluation of a geothermal ORC power plant
    Altun, A. F.
    Kilic, M.
    RENEWABLE ENERGY, 2020, 148 : 261 - 274
  • [9] A HYBRID GEOTHERMAL-SOLAR POWER SYSTEM: OPTIMAL DESIGN AND OPERATION
    Ghasemi, Hadi
    Mitsos, Alexander
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2013, VOL 6A, 2014,
  • [10] Design and simulation of a geothermal-solar combined chimney power plant
    Cao, Fei
    Li, Huashan
    Ma, Qiuming
    Zhao, Liang
    ENERGY CONVERSION AND MANAGEMENT, 2014, 84 : 186 - 195