Hotelling's T2 charts with variable sample size and control limit

被引:29
|
作者
Chen, Yan-Kwang
Hsieh, Kun-Lin
机构
[1] Natl Taichung Inst Technol, Dept Logist Engn & Management, Taichung, Taiwan
[2] Natl Taitung Univ, Dept Informat Management, Taitung 950, Taiwan
[3] Natl Taitung Univ, Res Grp Syst & Theoret Sci, Taitung 950, Taiwan
关键词
statistical quality control; multivariate control chart; genetic algorithms;
D O I
10.1016/j.ejor.2006.09.046
中图分类号
C93 [管理学];
学科分类号
12 ; 1201 ; 1202 ; 120202 ;
摘要
The ideas of variable sampling interval (VSI), variable sample size (VSS), variable sample size and sampling interval (VSSI), and variable parameters (VP) in the univariate case have been successfully applied to the multivariate case to improve the efficiency of Hotelling's T-2 chart with fixed sampling rate (FSR) in detecting small process shifts. However, the main disadvantage in using most of these control schemes is an increasing in the complexity due to the adaptive changes in sampling intervals. In this paper, retaining the lengths of sampling intervals constant, a variable sample size and control limit (VSSC) T-2 chart is proposed and described. The statistical efficiency of the VSSC T-2 chart in terms of the average time to signal a shift in process mean vector is compared with that of the VP, VSSI, VSS, VSI, and FSR T-2 charts. From the results of comparison, it shows that the VSSC T-2 chart for a (very) small shift in the process mean vector gives a better performance than the VSSI, VSS, VSI, and FSR T-2 charts; meanwhile, it presents a similar performance to the VP T-2 chart. Furthermore, from the viewpoint of practicability, it is more convenient for administrating the control chart than the VSI, VSSI, and VP T-2 chart. Thus, it may provide a good option for quick response to small shifts in a multivariate process. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1251 / 1262
页数:12
相关论文
共 50 条
  • [31] Adaptive Hotelling's T 2 Control Charts with Run Rules
    Lee, Ming Ha
    COMMUNICATIONS IN STATISTICS-THEORY AND METHODS, 2013, 42 (05) : 883 - 897
  • [32] PCA mix-based Hotelling's T2 multivariate control charts for intrusion detection system
    Mo Shaohui
    Tuerhong, Gulanbaier
    Wushouer, Mairidan
    Yibulayin, Tuergen
    IET INFORMATION SECURITY, 2022, 16 (03) : 161 - 177
  • [33] Bivariate copulas on the Hotelling's T2 control chart
    Sukparungsee, Saowanit
    Kuvattana, Sasigarn
    Busababodhin, Piyapatr
    Areepong, Yupaporn
    COMMUNICATIONS IN STATISTICS-SIMULATION AND COMPUTATION, 2018, 47 (02) : 413 - 419
  • [34] A generalization of Hotelling's T2
    Jorgensen, B
    Rajeswaran, J
    COMMUNICATIONS IN STATISTICS-THEORY AND METHODS, 2005, 34 (11) : 2179 - 2195
  • [35] Robust Hotelling's T2 control charts under non-normality: the case of t-Student distribution
    Alfaro, Jose-Luis
    Ortega, Juan-Fco.
    JOURNAL OF STATISTICAL COMPUTATION AND SIMULATION, 2012, 82 (10) : 1437 - 1447
  • [36] Bootstrapping analogs of the two-sample hotelling's T2 test
    Don, H. S. Rupasinghe Arachchige
    Watagoda, L. C. R. Pelawa
    COMMUNICATIONS IN STATISTICS-THEORY AND METHODS, 2018, 47 (09) : 2172 - 2182
  • [37] A double sampling multivariate T2 control chart with variable sample size and variable sampling interval
    Katebi, Mehdi
    Moghadam, M. Bameni
    COMMUNICATIONS IN STATISTICS-SIMULATION AND COMPUTATION, 2022, 51 (07) : 3578 - 3595
  • [38] Economic process control for multivariate quality characteristics with Hotelling's T2 Charts under Gamma shock model
    Li, FengChia
    Wang, PengKai
    Yeh, LiLon
    Hong, ShengWen
    2011 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING AND ENGINEERING MANAGEMENT (IEEM), 2011, : 1510 - 1513
  • [39] Condition monitoring of PEM fuel cell using hotelling T2 control limit
    Xue, X.
    Tang, J.
    Proceedings of the ASME Advanced Energy Systems Division, 2005, 45 : 113 - 125
  • [40] Hotelling’s T2 control chart with double warning lines
    Alireza Faraz
    Ahmad Parsian
    Statistical Papers, 2006, 47 : 569 - 593