Rapid detection of bacterial meningitis using a point-of-care glucometer

被引:17
|
作者
Rousseau, Geoffroy [1 ,5 ]
Asmolov, Romain [2 ,5 ]
Grammatico-Guillon, Leslie [3 ,5 ]
Auvet, Adrien [2 ,5 ]
Laribi, Said [1 ,5 ]
Garot, Denis [4 ]
Jouan, Youenn [4 ,5 ]
Dequin, Pierre-Francois [4 ,5 ]
Guillon, Antoine [4 ,5 ]
机构
[1] Teaching Hosp Tours, Emergency Dept, Tours, France
[2] Teaching Hosp Tours, Dept Anesthesiol & Intens Care, Tours, France
[3] Teaching Hosp Tours, Epidemiol Unit, Tours, France
[4] Teaching Hosp Tours, Dept Intens Care Med, Tours, France
[5] Francois Rabelais Univ, Tours, France
关键词
bacterial meningitis; cerebrospinal fluid/blood glucose ratio; emergency departments; point-of-care testing; GLUCOSE RATIO; MANAGEMENT; GUIDELINE; DIAGNOSIS; UNIT;
D O I
10.1097/MEJ.0000000000000495
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background In case of acute bacterial meningitis, a decision on the need for intensive care admission should be made within the first hour. The aim of this study was to assess the ability of a point-of-care glucometer to determine abnormal cerebrospinal fluid (CSF) glucose concentration at the bedside that contributes toward bacterial meningitis diagnosis. Methods We carried out a prospective study and simultaneously measured the glucose concentrations in CSF and blood using a central laboratory and a point-of-care glucometer. We compared CSF/blood glucose ratios obtained at the bedside with a glucometer versus those obtained by the central laboratory. We determined the performance characteristics of the CSF/blood glucose ratio provided by a glucometer to detect bacterial infection in the CSF immediately after CSF sampling. Results We screened 201 CSF collection procedures during the study period and included 172 samples for analysis. Acute bacterial meningitis was diagnosed in 17/172 (9.9%) of CSF samples. The median turnaround time for a point-of-care glucometer analysis was 5 (interquartile range 2-10) min versus 112 (interquartile range 86-154) min for the central laboratory (P<0.0001). The optimal cut-off of the CSF/blood glucose ratio calculated from a bedside glucometer was 0.46, with a sensitivity of 94.1% (95% confidence interval: 71.3-99.9%), a specificity of 91% (95% confidence interval: 85.3-95%), and a positive likelihood ratio of 10. Conclusion A glucometer accurately detects an abnormal CSF/blood glucose ratio immediately after the lumbar puncture. This cheap point-of-care method has the potential to speed up the diagnostic process of patients with bacterial meningitis. Copyright (c) 2017 Wolters Kluwer Health, Inc. All rights reserved.
引用
收藏
页码:41 / 46
页数:6
相关论文
共 50 条
  • [1] Rapid detection of bacterial meningitis using a glucometer in children
    Bin, Joong Hyun
    Lee, Soo-Young
    [J]. EUROPEAN JOURNAL OF EMERGENCY MEDICINE, 2020, 27 (06) : 470 - 471
  • [2] Validation of a point-of-care glucometer for use in dairy cows
    Wittrock, J. A. M.
    Duffield, T. F.
    LeBlanc, S. J.
    [J]. JOURNAL OF DAIRY SCIENCE, 2013, 96 (07) : 4514 - 4518
  • [3] Detection of Bacterial and Viral Pathogens Using Photonic Point-of-Care Devices
    Nath, Peuli
    Kabir, Alamgir
    Khoubafarin Doust, Somaiyeh
    Kreais, Zachary Joseph
    Ray, Aniruddha
    [J]. DIAGNOSTICS, 2020, 10 (10)
  • [4] Biosensors and Point-of-Care Devices for Bacterial Detection: Rapid Diagnostics Informing Antibiotic Therapy
    Gopal, Ashna
    Yan, Li
    Kashif, Saima
    Munshi, Tasnim
    Roy, Vellaisamy A. L.
    Voelcker, Nicolas H.
    Chen, Xianfeng
    [J]. ADVANCED HEALTHCARE MATERIALS, 2022, 11 (03)
  • [5] Response to: Bin JH, Lee S-Y. Rapid detection of bacterial meningitis using a glucometer in children.
    Rousseau, Geoffroy
    Grammatico-Guillon, Leslie
    Laribi, Said
    Guillon, Antoine
    [J]. EUROPEAN JOURNAL OF EMERGENCY MEDICINE, 2020, 27 (06) : 471 - 472
  • [6] Electrochemical immunosensor for point-of-care quantitative detection of tumor markers based on personal glucometer
    Xu, Yang
    Wang, Huiqiang
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2022, 915
  • [7] Rapid exclusion of bacterial arthritis using a glucometer
    Mohamed Omar
    Moritz Reichling
    Emmanouil Liodakis
    Max Ettinger
    Daniel Guenther
    Sebastian Decker
    Christian Krettek
    Eduardo M. Suero
    Philipp Mommsen
    [J]. Clinical Rheumatology, 2017, 36 : 591 - 598
  • [8] Novel diagnostics for point-of-care bacterial detection and identification
    Reali, Savannah
    Najib, Elias Y.
    Balazs, Krisztina E. Treuerne
    Tan, Adeline Chern Hui
    Varadi, Linda
    Hibbs, David E.
    Groundwater, Paul W.
    [J]. RSC ADVANCES, 2019, 9 (37) : 21486 - 21497
  • [9] EVALUATION OF A RAPID POINT-OF-CARE TEST FOR DETECTION OF CRYPTOSPORIDIUM
    Fleece, Molly E.
    Khan, Shaila S.
    Kabir, Mamum
    Haque, Rashidul
    Petri, William A., Jr.
    [J]. AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2015, 93 (04): : 352 - 352
  • [10] Novel point-of-care rapid detection of monkeypox virus
    Chen, Hui
    Guan, Yuhong
    Zhang, Xinyu
    Chen, Yuting
    Li, Song
    Deng, Yan
    Wu, Yanqi
    [J]. ANALYTICAL METHODS, 2024, 16 (37) : 6403 - 6410