Rapid detection of bacterial meningitis using a point-of-care glucometer

被引:17
|
作者
Rousseau, Geoffroy [1 ,5 ]
Asmolov, Romain [2 ,5 ]
Grammatico-Guillon, Leslie [3 ,5 ]
Auvet, Adrien [2 ,5 ]
Laribi, Said [1 ,5 ]
Garot, Denis [4 ]
Jouan, Youenn [4 ,5 ]
Dequin, Pierre-Francois [4 ,5 ]
Guillon, Antoine [4 ,5 ]
机构
[1] Teaching Hosp Tours, Emergency Dept, Tours, France
[2] Teaching Hosp Tours, Dept Anesthesiol & Intens Care, Tours, France
[3] Teaching Hosp Tours, Epidemiol Unit, Tours, France
[4] Teaching Hosp Tours, Dept Intens Care Med, Tours, France
[5] Francois Rabelais Univ, Tours, France
关键词
bacterial meningitis; cerebrospinal fluid/blood glucose ratio; emergency departments; point-of-care testing; GLUCOSE RATIO; MANAGEMENT; GUIDELINE; DIAGNOSIS; UNIT;
D O I
10.1097/MEJ.0000000000000495
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background In case of acute bacterial meningitis, a decision on the need for intensive care admission should be made within the first hour. The aim of this study was to assess the ability of a point-of-care glucometer to determine abnormal cerebrospinal fluid (CSF) glucose concentration at the bedside that contributes toward bacterial meningitis diagnosis. Methods We carried out a prospective study and simultaneously measured the glucose concentrations in CSF and blood using a central laboratory and a point-of-care glucometer. We compared CSF/blood glucose ratios obtained at the bedside with a glucometer versus those obtained by the central laboratory. We determined the performance characteristics of the CSF/blood glucose ratio provided by a glucometer to detect bacterial infection in the CSF immediately after CSF sampling. Results We screened 201 CSF collection procedures during the study period and included 172 samples for analysis. Acute bacterial meningitis was diagnosed in 17/172 (9.9%) of CSF samples. The median turnaround time for a point-of-care glucometer analysis was 5 (interquartile range 2-10) min versus 112 (interquartile range 86-154) min for the central laboratory (P<0.0001). The optimal cut-off of the CSF/blood glucose ratio calculated from a bedside glucometer was 0.46, with a sensitivity of 94.1% (95% confidence interval: 71.3-99.9%), a specificity of 91% (95% confidence interval: 85.3-95%), and a positive likelihood ratio of 10. Conclusion A glucometer accurately detects an abnormal CSF/blood glucose ratio immediately after the lumbar puncture. This cheap point-of-care method has the potential to speed up the diagnostic process of patients with bacterial meningitis. Copyright (c) 2017 Wolters Kluwer Health, Inc. All rights reserved.
引用
收藏
页码:41 / 46
页数:6
相关论文
共 50 条
  • [31] Point-of-care nucleic acid detection using nanotechnology
    Hartman, Mark R.
    Ruiz, Roanna C. H.
    Hamada, Shogo
    Xu, Chuanying
    Yancey, Kenneth G.
    Yu, Yan
    Han, Wei
    Luo, Dan
    [J]. NANOSCALE, 2013, 5 (21) : 10141 - 10154
  • [32] LAMP-Based Point-of-Care Biosensors for Rapid Pathogen Detection
    Das, Dhrubajyoti
    Lin, Cheng-Wen
    Chuang, Han-Sheng
    [J]. BIOSENSORS-BASEL, 2022, 12 (12):
  • [33] Rapid, Sensitive, and Accurate Point-of-Care Detection of Lethal Amatoxins in Urine
    Bever, Candace S.
    Swanson, Kenneth D.
    Hamelin, Elizabeth I.
    Filigenzi, Michael
    Poppenga, Robert H.
    Kaae, Jennifer
    Cheng, Luisa W.
    Stanker, Larry H.
    [J]. TOXINS, 2020, 12 (02)
  • [34] A Rapid Point-of-Care Assay for Cysticercosis Antigen Detection in Urine Samples
    Toribio, Luz
    Handali, Sukwan
    Marin, Yazmin
    Perez, Erika
    Castillo, Yesenia
    Bustos, Javier A.
    O'Neal, Seth E.
    Garcia, Hector H.
    Cysticerco Working Grp Peru
    [J]. AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2023, 108 (03): : 578 - 580
  • [35] Microfluidic system for rapid detection of contagious bovine pleuropneumonia at the point-of-care
    Nepper, Julia F.
    Liljander, Anne
    Irizarry, Pedro J. Resto
    Zan, Jindong
    Jores, Joeerg
    Weibel, Douglas B.
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 247
  • [36] Evaluation of a Rapid Lateral Flow Point-of-Care Test for Detection of Cryptosporidium
    Fleece, Molly E.
    Heptinstall, Jack
    Khan, Shaila S.
    Kabir, Mamum
    Herbein, Joel
    Haque, Rashidul
    Petri, William A., Jr.
    [J]. AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2016, 95 (04): : 840 - 841
  • [37] A new point-of-care test for the rapid detection of urinary tract infections
    Arienzo, Alyexandra
    Cellitti, Valentina
    Ferrante, Valeria
    Losito, Francesca
    Stalio, Ottavia
    Murgia, Lorenza
    Marino, Rossella
    Cristofano, Flavia
    Orru, Michela
    Visca, Paolo
    Di Somma, Salvatore
    Silvestri, Lorena
    Ziparo, Vincenzo
    Antonini, Giovanni
    [J]. EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2020, 39 (02) : 325 - 332
  • [38] A new point-of-care test for the rapid detection of urinary tract infections
    Alyexandra Arienzo
    Valentina Cellitti
    Valeria Ferrante
    Francesca Losito
    Ottavia Stalio
    Lorenza Murgia
    Rossella Marino
    Flavia Cristofano
    Michela Orrù
    Paolo Visca
    Salvatore Di Somma
    Lorena Silvestri
    Vincenzo Ziparo
    Giovanni Antonini
    [J]. European Journal of Clinical Microbiology & Infectious Diseases, 2020, 39 : 325 - 332
  • [39] Sensitive point-of-care monitoring of HIV related DNA sequences with a personal glucometer
    Xu, Jin
    Jiang, Bingying
    Xie, Jiaqing
    Xiang, Yun
    Yuan, Ruo
    Chai, Yaqin
    [J]. CHEMICAL COMMUNICATIONS, 2012, 48 (87) : 10733 - 10735
  • [40] Point-of-care multiplexed diagnosis of meningitis using the FilmArray® ME panel technology
    Vincent, Jean-Jacques
    Zandotti, Christine
    Baron, Sophie
    Kandi, Christian
    Levy, Pierre-Yves
    Drancourt, Michel
    Raoult, Didier
    Ninove, Laetitia
    [J]. EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2020, 39 (08) : 1573 - 1580