Gold nanoparticle modified electrodes show a reduced interference by Cu(II) in the detection of As(III) using anodic stripping voltammetry

被引:110
|
作者
Dai, X [1 ]
Compton, RG [1 ]
机构
[1] Univ Oxford, Phys & Theoret Chem Lab, Oxford OX1 3QZ, England
关键词
gold nanoparticles; copper(II) interference; arsenic(III) detection; anodic stripping voltammetry (ASV);
D O I
10.1002/elan.200403246
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Interference by Cu(II) causes serious problems in the detection of As(III) using anodic stripping voltammetry at gold electrodes. The behavior of Cu(II) and As(III) were examined at both a gold macro electrode and two kinds of gold nanoparticle modified electrodes, one where gold particles are deposited on glassy carbon (GC) and the other where basal plane pyrolytic graphite (BPPG) is the substrate. The sensitivity of As(III) detection was higher on gold nanoparticle modified electrodes than those on a macro gold electrode by up to an order of magnitude. In addition, the stripping peak of As(III) was narrower and more symmetric on a gold nanoparticle-modified GC electrode, leading to analytical data with a lower limit of detection. At a macro gold electrode, the peak currents of Cu(II) were higher than those on gold nanoparticle modified electrodes. Accordingly, through the use of gold nanoparticle modified electrodes, the effect of copper interference to the arsenic detection can be reduced.
引用
收藏
页码:1325 / 1330
页数:6
相关论文
共 50 条
  • [1] Anodic stripping voltammetry of arsenic(III) using gold nanoparticle-modified electrodes
    Dai, X
    Nekrassova, O
    Hyde, ME
    Compton, RG
    ANALYTICAL CHEMISTRY, 2004, 76 (19) : 5924 - 5929
  • [2] Sensitive electrochemical detection of arsenic (III) using gold nanoparticle modified carbon nanotubes via anodic stripping voltammetry
    Xiao, Lei
    Wildgoose, Gregory G.
    Compton, Richard G.
    ANALYTICA CHIMICA ACTA, 2008, 620 (1-2) : 44 - 49
  • [3] Anodic stripping voltammetry of antimony using gold nanoparticle-modified carbon screen-printed electrodes
    Dominguez Renedo, Olga
    Arcos Martinez, M. Julia
    ANALYTICA CHIMICA ACTA, 2007, 589 (02) : 255 - 260
  • [4] Sensitive detection of Pb(II) at gold nanoparticle/polyaniline/graphene modified electrode using differential pulse anodic stripping voltammetry
    Dong, YongPing
    Zhou, Ying
    Ding, Yong
    Chu, XiangFeng
    Wang, ChengMing
    ANALYTICAL METHODS, 2014, 6 (23) : 9367 - 9374
  • [5] DETERMINATION OF AS(III) BY ANODIC-STRIPPING PULSE VOLTAMMETRY USING GOLD AND GLASSY-CARBON ELECTRODES
    RAMADAN, AA
    MANDIL, H
    INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 1989, 28 (11): : 984 - 988
  • [6] A novel method for the anodic stripping voltammetry determination of Sb(III) using silver nanoparticle-modified screen-printed electrodes
    Renedo, Olga Dominguez
    Martinez, M. Julia Arcos
    ELECTROCHEMISTRY COMMUNICATIONS, 2007, 9 (04) : 820 - 826
  • [7] Determination of As(III) by anodic stripping voltammetry following double deposition and stripping steps at two gold working electrodes
    Korolczuk, Mieczyslaw
    Ochab, Mateusz
    Rutyna, Iwona
    TALANTA, 2015, 144 : 517 - 521
  • [8] Determination of mercury by anodic stripping voltammetry with a gold nanoparticle-modified glassy carbon electrode
    Abollino, Ornella
    Giacomino, Agnese
    Malandrino, Mery
    Piscionieri, Giuseppina
    Mentasti, Edoardo
    ELECTROANALYSIS, 2008, 20 (01) : 75 - 83
  • [9] Anodic Stripping Voltammetric Detection of Arsenic(III) at Gold Nanoparticle-Modified Glassy Carbon Electrodes Prepared by Electrodeposition in the Presence of Various Additives
    Hossain, Md Motahar
    Islam, Md. Mominul
    Ferdousi, Sara
    Okajima, Takeyoshi
    Ohsaka, Takeo
    ELECTROANALYSIS, 2008, 20 (22) : 2435 - 2441
  • [10] Anodic stripping voltammetry with carbon paste electrodes for rapid Ag(I) and Cu(II) determinations
    Labar, C
    Lamberts, L
    TALANTA, 1997, 44 (05) : 733 - 742