Sensitive detection of Pb(II) at gold nanoparticle/polyaniline/graphene modified electrode using differential pulse anodic stripping voltammetry

被引:47
|
作者
Dong, YongPing [1 ]
Zhou, Ying [1 ]
Ding, Yong [1 ]
Chu, XiangFeng [1 ]
Wang, ChengMing [2 ]
机构
[1] Anhui Univ Technol, Sch Chem & Chem Engn, Maanshan 243002, Peoples R China
[2] Univ Sci & Technol China, Hefei Natl Lab Phys Sci Microscale, Hefei 230026, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
WALLED CARBON NANOTUBES; FILM ELECTRODE; HYBRID SYSTEMS; GRAPHENE OXIDE; THIN-FILMS; METAL-IONS; POLYANILINE; COMPOSITES; NANOPARTICLES; POLYPYRROLE;
D O I
10.1039/c4ay01908c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a gold nanoparticle/polyaniline/graphene ternary nanocomposite modified glassy carbon electrode (GNP/PANI/GR/GCE) was prepared and characterized by scanning electron microscopy, spectroscopic techniques, and electrochemical techniques. It was found that the GNP/PANI/GR nanocomposite exhibited a good synergetic effect on the electrochemical signal from Pb2+, which is more efficient than that of electrodes modified with the individual materials. The modified electrode could be applied in the sensitive detection of Pb2+ by differential pulse anodic stripping voltammetry (DPASV). Several experimental parameters, such as the ratio of aniline/graphene, the amount of suspension modified on the electrode, the pH, the diameter of gold nanoparticles, the deposition time, and the potential of Pb2+ were optimized. Under the optimal conditions, a good linear relationship between the stripping peak currents and the concentration of Pb2+ was obtained in the range of 0.5 to 10 nM with a correlation coefficient of 0.9995 and a detection limit of 0.1 nM. The proposed method is applicable in the determination of trace Pb2+ in real water samples with a relative standard deviation less than 3.5% and recovery rates of similar to 99%.
引用
收藏
页码:9367 / 9374
页数:8
相关论文
共 50 条
  • [1] Differential Pulse Anodic Stripping Voltammetry Detection of Cadmium with Nafion-Graphene Modified Bismuth Film Electrode
    Wu, Saiwei
    Huang, Xiaolei
    Wu, Yuhua
    Luo, Liping
    Jin, Yuancheng
    Li, Qun
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (10): : 8255 - 8262
  • [2] Simultaneous detection of trace Cd(II) and Pb(II) by differential pulse anodic stripping voltammetry using a bismuth oxycarbide/nafion electrode
    Zhang, Yaxiao
    Li, Chao
    Su, Yingchun
    Mu, Wei
    Han, Xiaojun
    INORGANIC CHEMISTRY COMMUNICATIONS, 2020, 111
  • [3] Simultaneous determination of Cd(II) and Pb(II) using square wave anodic stripping voltammetry at a gold nanoparticle-graphene-cysteine composite modified bismuth film electrode
    Zhu, Lian
    Xu, Lili
    Huang, Baozhen
    Jia, Ningming
    Tan, Liang
    Yao, Shouzhuo
    ELECTROCHIMICA ACTA, 2014, 115 : 471 - 477
  • [4] Sensitive electrochemical detection of arsenic (III) using gold nanoparticle modified carbon nanotubes via anodic stripping voltammetry
    Xiao, Lei
    Wildgoose, Gregory G.
    Compton, Richard G.
    ANALYTICA CHIMICA ACTA, 2008, 620 (1-2) : 44 - 49
  • [5] Simultaneous Determination of Zn(II), Cd(II), Pb(II), and Cu(II) Using Differential Pulse Anodic Stripping Voltammetry at a Bismuth Film-Modified Electrode
    Nguyen Mau Thanh
    Nguyen Van Hop
    Nguyen Dinh Luyen
    Nguyen Hai Phong
    Tran Thanh Tam Toan
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2019, 2019
  • [6] Gold nanoparticle modified electrodes show a reduced interference by Cu(II) in the detection of As(III) using anodic stripping voltammetry
    Dai, X
    Compton, RG
    ELECTROANALYSIS, 2005, 17 (14) : 1325 - 1330
  • [7] Determination of Pb and Zn in pottery using differential pulse anodic stripping voltammetry
    Ghumare, S
    Joshi, AP
    INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 1998, 37 (10): : 942 - 944
  • [8] The Graphene/L-Cysteine/Gold-Modified Electrode for the Differential Pulse Stripping Voltammetry Detection of Trace Levels of Cadmium
    Song, Yu
    Bian, Chao
    Tong, Jianhua
    Li, Yang
    Xia, Shanghong
    MICROMACHINES, 2016, 7 (06):
  • [9] POLAROGRAPHY AND DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY OF PB(II)/POLYCARBOXYLATE COMPLEXES
    DIAZCRUZ, JM
    ARINO, C
    ESTEBAN, M
    CASASSAS, E
    VANLEEUWEN, HP
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1993, 344 (1-2): : 119 - 134
  • [10] Determination of mercury by anodic stripping voltammetry with a gold nanoparticle-modified glassy carbon electrode
    Abollino, Ornella
    Giacomino, Agnese
    Malandrino, Mery
    Piscionieri, Giuseppina
    Mentasti, Edoardo
    ELECTROANALYSIS, 2008, 20 (01) : 75 - 83