Effects of tetrahedral amorphous carbon film deposited on dental cobalt-chromium alloys on bacterial adhesion

被引:24
|
作者
Chen, Gang [2 ,3 ]
Wang, Zhongyi [2 ]
Wang, Hui [2 ]
Zhao, Xiaolin [3 ]
Hu, Jiang [4 ]
Wang, Shaohai [1 ]
Zhang, Shaofeng [2 ]
机构
[1] Second Mil Med Univ, Dept Stomatol, Changhai Hosp, Shanghai 200433, Peoples R China
[2] Fourth Mil Med Univ, Sch Stomatol, Dept Prosthodont, Xian 710032, Shaanxi Provinc, Peoples R China
[3] PLA, Hosp 32, Dept Stomatol, Xian 710054, Shaanxi Provinc, Peoples R China
[4] Jilin Med Coll, Dept Stomatol, Affiliated Hosp, Changchun 132013, Jilin Province, Peoples R China
来源
SURFACE & COATINGS TECHNOLOGY | 2012年 / 206卷 / 15期
基金
中国国家自然科学基金;
关键词
Cobalt-chromium alloy; Tetrahedral amorphous carbon film; Surface roughness; Surface free energy; Bacterial adhesion; DIAMOND-LIKE CARBON; FILTERED CATHODIC VACUUM; SURFACE FREE-ENERGY; BIOMEDICAL APPLICATIONS; STREPTOCOCCUS-MUTANS; BIOFILM FORMATION; COATINGS; ARC; ROUGHNESS; RAMAN;
D O I
10.1016/j.surfcoat.2012.01.059
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The dental cobalt-chromium alloys are an important biomaterial used in making artificial dentures. Bacterial adhesion to cobalt-chromium alloys usually results in severe complications such as periodontal infection, secondary caries, and denture stomatitis, which have severe adverse impacts on human health. Therefore, an effective method is needed to reduce the bacterial adhesion to dental cobalt-chromium alloys. The aim of this study was to investigate the effects of ta-C films deposited on a dental cobalt-chromium alloy on the adhesion of Streptococcus mutans (ATCC175), Actinomyces viscosus (ATCC19246) and Candida albicans (ATCC76615). A filtered cathodic vacuum arc (FCVA) technique was used to coat the cobalt-chromium alloy with a ta-C film. Atomic force microscopy (AFM), Raman spectroscopy and X-ray photoelectron spectroscopy (XPS) were used to analyze the surface characteristics of the coating. Surface roughness was detected. Surface free energy and its components were calculated by measuring the contact angle. The results showed that the maximum sp(3) fraction was achieved at 200 V substrate bias voltage. Compared with uncoated specimens, the ta-C film coated specimens had a lower surface roughness, a higher surface energy and a higher hydrophilicity. Most importantly, the adhesion of the three tested bacterial strains to the ta-C film coated cobalt-chromium alloy was significantly decreased. These results showed that ta-C film surface treatment could significantly reduce the bacterial adhesion to dental cobalt-chromium alloys, suggesting the potential of ta-C film surface treatment in artificial denture applications. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:3386 / 3392
页数:7
相关论文
共 43 条
  • [1] Evaluation of Bacterial Adhesion to Nanocrystalline Diamond Coated Cobalt-Chromium Dental Alloy
    Lukomska-Szymanska, Monika
    Cajdler, Marcin
    Klimek, Leszek
    Sokolowski, Jerzy
    DENTAL AND MEDICAL PROBLEMS, 2009, 46 (04) : 424 - 430
  • [2] COMPARISON AND CLASSIFICATION OF COBALT-CHROMIUM DENTAL CASTING ALLOYS
    PADDON, JM
    WILSON, AD
    JOURNAL OF DENTAL RESEARCH, 1972, 51 (05) : 1275 - &
  • [3] SOME PROPERTIES OF 2 DENTAL COBALT-CHROMIUM ALLOYS
    BERGMAN, M
    HOLMLUND, L
    SOREMARK, R
    ODONTOLOGISK REVY, 1974, 25 (02): : 179 - 188
  • [4] Evaluation of Bacterial Adhesion to the ZrO2 Atomic Layer Deposited on the Surface of Cobalt-Chromium Dental Alloy Produced by DMLS Method
    Ziebowicz, Anna
    Sambok-Kielbowicz, Agata
    Walke, Witold
    Mzyk, Aldona
    Kosiel, Kamil
    Kubacki, Jerzy
    Baczkowski, Bohdan
    Pawlyta, Miroslawa
    Ziebowicz, Boguslaw
    MATERIALS, 2021, 14 (05) : 1 - 15
  • [5] Corrosion behaviour of cobalt-chromium dental alloys doped with precious metals
    Reclaru, L
    Lüthy, H
    Eschler, PY
    Blatter, A
    Susz, C
    BIOMATERIALS, 2005, 26 (21) : 4358 - 4365
  • [6] Interfacial Property of Dental Cobalt-Chromium Alloys and Their Bonding Strength with Porcelains
    Park, Won Uk
    Park, Hui Geun
    Hwang, Kyu Hong
    Zhao, Jingming
    Lee, Jong Kook
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2017, 17 (04) : 2585 - 2588
  • [7] The effects of amorphous carbon films deposited on polyethylene terephthalate on bacterial adhesion
    Wang, J
    Huang, N
    Yang, P
    Leng, Y
    Sun, H
    Liu, ZY
    Chu, PK
    BIOMATERIALS, 2004, 25 (16) : 3163 - 3170
  • [8] SYSTEMIC EFFECTS OF IMPLANTED PROSTHESES MADE OF COBALT-CHROMIUM ALLOYS
    MICHEL, R
    NOLTE, M
    REICH, M
    LOER, F
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1991, 110 (02) : 61 - 74
  • [9] Study on the Surface of Cobalt-Chromium Dental Alloys and Their Behavior in Oral Cavity as Cast Materials
    Uriciuc, Willi Andrei
    Bosca, Adina Bianca
    Babtan, Anida-Maria
    Vermesan, Horatiu
    Cristea, Cecilia
    Tertis, Mihaela
    Pascuta, Petru
    Borodi, Gheorghe
    Suciu, Maria
    Barbu-Tudoran, Lucian
    Popa, Catalin Ovidiu
    Ilea, Aranka
    MATERIALS, 2022, 15 (09)
  • [10] ADHESION OF DENTAL PORCELAIN TO CAST, MILLED, AND LASER-SINTERED COBALT-CHROMIUM ALLOYS: SHEAR BOND STRENGTH AND SENSITIVITY TO THERMOCYCLING
    Serra-Prat, Josep
    Cano-Batalla, Jordi
    Cabratosa-Termes, Josep
    Figueras-Alvarez, Oscar
    JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (03): : 600 - 605