Single-Sided Partial Discharge Location Method Based on Impedance Discontinuities along Power Cable

被引:0
|
作者
Li, Yan [1 ]
Wouters, Peter A. A. F. [1 ]
Wagenaarst, Paul [2 ]
van der Wielent, Peter C. J. M. [2 ]
Steennist, E. Fred [1 ,2 ]
机构
[1] Eindhoven Univ Technol, Elect Energy Syst Grp, Eindhoven, Netherlands
[2] DNV GL Energy, Anthem, Netherlands
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Time domain reflectometry (TDR) applied to live cables is hampered by the absence of a clear reflection from the far end. Instead, location of partial discharge (PD) can be extracted from small structures in recorded patterns arising from any impedance variation along the signal propagation channel. This paper explores two approaches for a single-sided PD location system. The first method compares similar signal sequences occurring in PD pattern and pattern obtained from an injected signal. The second method exploits the change of impedance at a far end Ring Main Unit (RMU) by introducing ferrite material, whose effect can be switched on and off. Experiment on medium voltage (MV) cable with about 560 m length shows that both methods can locate the PD within 2% uncertainty.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Research on cable partial discharge detection and location system based on optical fibre timing
    Zhang, Jianjun
    Peng, Fang
    Xie, Anming
    Fei, Yang
    INTERNATIONAL JOURNAL OF COMPUTER APPLICATIONS IN TECHNOLOGY, 2022, 69 (03) : 298 - 307
  • [22] A Thermal Excitation Based Partial Discharge Detection Method for Cable Accessory
    Li, Zerui
    Zhou, Kai
    Xu, Xiangdong
    Meng, Pengfei
    Fu, Yao
    Zeng, Zijin
    IEEE TRANSACTIONS ON POWER DELIVERY, 2023, 38 (04) : 2703 - 2710
  • [23] Research on Partial Discharge Location Method of DC Wall Bushing Based on Partial Discharge Transfer Ratio
    Pan, Zhicheng
    Zhang, Jinyin
    Xie, Zhicheng
    Deng, Jun
    2023 5TH ASIA ENERGY AND ELECTRICAL ENGINEERING SYMPOSIUM, AEEES, 2023, : 191 - 194
  • [24] Investigating the progression of insulation degradation in power cable based on partial discharge measurements
    Hassan, Waqar
    Shafiq, Muhammad
    Hussain, Ghulam Amjad
    Choudhary, Maninder
    Palu, Ivo
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 221
  • [25] Identification of Partial Discharge Location in a Power Cable Using Fuzzy Inference System and Probabilistic Neural Networks
    Su, Ming-Shou
    Chen, Jiann-Fuh
    Lin, Yu-Hsun
    Cheng, Chih-Kun
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2012, 40 (06) : 613 - 627
  • [26] Partial Discharge Location in Power Cables using a Double Ended Method Based on Time Triggering with GPS
    Mohamed, F. P.
    Siew, W. H.
    Soraghan, J. J.
    Strachan, S. M.
    McWilliam, J.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (06) : 2212 - 2221
  • [27] Identification and Location of Local Defects in Power Cable Body Based on Input Impedance Spectroscopy
    Li R.
    Zhou K.
    Wan H.
    Xie M.
    Rao X.
    Zhou, Kai (zhoukai_scu@163.com), 1743, China Machine Press (36): : 1743 - 1751
  • [28] A New Method for Detecting Partial Discharge in T-Type Terminals of Power Cable
    Lu, Binxian
    Sun, Xinyu
    Yang, Haoshuo
    Xiong, Jun
    Wu, Zheng
    Hu, Fei
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2024, 71 (02) : 2049 - 2059
  • [29] Methods for Remaining Life Prediction of Power Cable based on Partial Discharge and Cable Failure History Data
    Zaeni, Arpan
    Khayam, Umar
    Viviantoro, Deny
    PROCEEDING OF 2019 INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND INFORMATICS (ICEEI), 2019, : 662 - 665
  • [30] Neural-network-based single-sided non-enwrapping power loss tester
    Passadis, K
    Meydan, T
    Beckley, P
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2003, 254 : 385 - 387