Repeatability of Transient-Evoked Otoacoustic Emissions in Young Adults

被引:0
|
作者
Kochanek, Krzysztof M. [1 ,2 ,3 ]
Sliwa, Lech K. [1 ,2 ]
Puchacz, Klaudia [3 ]
Pilka, Adam [1 ,2 ]
机构
[1] Inst Physiol & Pathol Hearing, Dept Expt Audiol, Warsaw, Poland
[2] World Hearing Ctr, Kajetany, Poland
[3] Marie Curie Sklodowska Univ, Dept Logopaed & Appl Linguist, Lublin, Poland
来源
MEDICAL SCIENCE MONITOR | 2015年 / 21卷
关键词
Audiology; Biomedical Technology; Otoacoustic Emissions; Spontaneous; TEST-RETEST RELIABILITY; HEARING-LOSS; DISTORTION-PRODUCT; RESONANT MODES; NOISE; TINNITUS; CHILDREN; TERM; EAR;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: The aim of this study was to evaluate the repeatability and variability of TEOAE characteristics in hearing screening tests performed under practical conditions on normal subjects. Material/Methods: A group of 11 young, normal-hearing subjects aged 19-24 years was tested. They were examined otologically and audiologically prior to the tests and no ear pathologies were found. Responses were acquired with a commercially available instrument (Integrity, Vivosonic Inc.) using a standardized OAE protocol. The TEOAE tests were repeated 3 times in each subject at random intervals within 24 h. The analyzed parameters of interest were: (i) whole wave reproducibility (WWR) and; (ii) signal-to-noise ratio (SNR). Results: WWR and SNR did not differ significantly among the 3 measurement sessions. In most cases the differences in WWR among measurements were around 1-2% and for SNRs they were 1-4 dB SNRs and were highest in the 1-2 kHz range. TEOAE-based tests can be useful tools for hearing screening. Conclusions: The tests can give reliable results provided that adequate procedures are used and low-noise conditions are ensured. The tests are best complemented with other examinations to widen the range of ear pathologies able to be detected.
引用
收藏
页码:36 / 43
页数:8
相关论文
共 50 条
  • [41] Transient-evoked otoacoustic emissions in a representative population sample aged 18 to 25 years
    Ferguson, MA
    Smith, PA
    Davis, AC
    Lutman, ME
    [J]. AUDIOLOGY, 2000, 39 (03): : 125 - 134
  • [42] Contralateral frequency-modulated tones suppress transient-evoked otoacoustic emissions in humans
    Maison, S
    Micheyl, C
    Collet, L
    [J]. HEARING RESEARCH, 1998, 117 (1-2) : 114 - 118
  • [43] Revisiting the transient-evoked otoacoustic emissions passing criteria used for newborn hearing screening
    Mackey, Allison
    Maeki-Torkko, Elina
    Uhlen, Inger
    [J]. INTERNATIONAL JOURNAL OF AUDIOLOGY, 2024,
  • [44] Optimal one- and two-dimensional filtering of transient-evoked otoacoustic emissions
    Ravazzani, P
    Tognola, G
    Ruohonen, J
    Grandori, F
    [J]. BRITISH JOURNAL OF AUDIOLOGY, 1997, 31 (06): : 479 - 491
  • [45] Characteristics of normal newborn transient-evoked otoacoustic emissions: Ear asymmetries and sex effects
    Berninger, Erik
    [J]. INTERNATIONAL JOURNAL OF AUDIOLOGY, 2007, 46 (11) : 661 - 669
  • [46] Short-latency transient-evoked otoacoustic emissions as predictors of hearing status and thresholds
    Mertes, Ian B.
    Goodman, Shawn S.
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2013, 134 (03): : 2127 - 2135
  • [47] Transient evoked otoacoustic emissions
    Kapoor R.
    Panda N.K.
    [J]. The Indian Journal of Pediatrics, 2006, 73 (4) : 283 - 286
  • [48] A Clinically Viable Medial Olivocochlear Reflex Assay Using Transient-Evoked Otoacoustic Emissions
    Lapsley Miller, Judi A.
    Reed, Charlotte M.
    Marshall, Lynne
    Perez, Zachary D.
    Villabona, Timothy
    [J]. EAR AND HEARING, 2024, 45 (01): : 115 - 129
  • [49] Localization of hearing loss on the basis of transient-evoked otoacoustic emissions by using wavelet transform
    Zheng, L
    Ye, DT
    Yang, FS
    Zhang, YT
    [J]. PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 1531 - 1534
  • [50] Principal component analysis as a method to facilitate fast detection of transient-evoked otoacoustic emissions
    Ravazzani, P
    Tognola, G
    Parazzini, M
    Grandori, F
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (02) : 249 - 252