Exposure levels of CT and conventional X-ray procedures for radiosensitive pelvic organ in Saudi Arabia

被引:6
|
作者
Osman, Hamid [1 ]
Raafat, Bassem M. [1 ]
Faizo, Nahla L. [1 ]
Ahmed, Rania Mohammed [1 ]
Alamri, Sultan [1 ]
Alghamdi, Ahmad Joman [1 ]
Almahwasi, Ashraf [2 ,3 ]
Alharbi, M. K. M. [1 ]
Sulieman, A. [4 ]
Khandaker, Mayeen Uddin [5 ]
机构
[1] Taif Univ, Coll Appl Med Sci, Radiol Sci Dept, At Taif, Saudi Arabia
[2] Minist Interior, Med Serv, Riyadh, Saudi Arabia
[3] Taif Univ, Prince Sultan Complex, Cent Labs, Sci Res, At Taif, Saudi Arabia
[4] Prince Sattam Bin Abdulaziz Univ, Coll Appl Med Sci, Radiol & Med Imaging Dept, Alkharj, Saudi Arabia
[5] Sunway Univ, Ctr Appl Phys & Radiat Technol, Sch Engn & Technol, Bandar Sunway 47500, Malaysia
关键词
X-ray; computed tomography; pelvis radiation dose; comparison; DRLs; COMPUTED-TOMOGRAPHY SCANNERS; RADIATION-EXPOSURE;
D O I
10.1080/16878507.2021.2002005
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Radiosensitive organs in the pelvic cavity of 313 patients were exposed to low-dose diagnostic radiation to assess the entrance surface air dose (ESD) and effective doses (ED), and also to compare the X-ray and computed tomography (CT) dose levels. The patients were examined at King Abdul Aziz Specialist Hospital and King Faisal Medical Complex in Taif City, Saudi Arabia for 4 months in 2020. In conventional pelvic imaging, the DOSCAL software was used to assess the ESD. To estimate the CT radiation dose to the pelvis, the CT dose index (CTDIw, usually CTDIvol) and dose length product (DLP) were utilized. For routine pelvic X-ray imaging, the mean ESD and ED were found to be 7.2 mGy and 0.38 mSv, respectively. For CT imaging, the mean values of CTDIw, DLP, and ED were found to be 10.9 mGy, 593 mGy-cm, and 8.9 mSv, respectively. The obtained values of ESD and ED were found in agreement with the reported data available in the literature. However, a significant variation has been observed for conventional X-ray and CT doses among the selected hospitals. In comparison to conventional radiography, the CT induces 20 times higher doses to pelvic organs. The obtained results may help to establish the local diagnostic reference levels (DRLs).
引用
收藏
页码:449 / 455
页数:7
相关论文
共 50 条
  • [41] Radiation exposure of medical staff from interventional x-ray procedures: a multicentre study
    Haeusler, Uwe
    Czarwinski, Renate
    Brix, Gunnar
    EUROPEAN RADIOLOGY, 2009, 19 (08) : 2000 - 2008
  • [42] Radiation exposure of medical staff from interventional x-ray procedures: a multicentre study
    Uwe Häusler
    Renate Czarwinski
    Gunnar Brix
    European Radiology, 2009, 19 : 2000 - 2008
  • [43] Signal-to-noise and radiation exposure considerations in conventional and diffraction x-ray microscopy
    Huang, Xiaojing
    Miao, Huijie
    Steinbrener, Jan
    Nelson, Johanna
    Shapiro, David
    Stewart, Andrew
    Turner, Joshua
    Jacobsen, Chris
    OPTICS EXPRESS, 2009, 17 (16): : 13541 - 13553
  • [44] The influence of calculated CT X-ray spectra on organ absorbed dose to a human phantom
    Ferreira, C. C.
    Vieira, J. W.
    Maia, A. F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2009, 267 (20): : 3447 - 3455
  • [45] Laminography in the lab: imaging planar objects using a conventional x-ray CT scanner
    Fisher, S. L.
    Holmes, D. J.
    Jorgensen, J. S.
    Gajjar, P.
    Behnsen, J.
    Lionheart, W. R. B.
    Withers, P. J.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2019, 30 (03)
  • [46] Quality assessment of conventional X-ray diagnostic equipment by measuring X-ray exposure and tube output parameters in Great Khorasan Province, Iran
    Hashemi M.
    Bayani S.
    Shahedi F.
    Momennezhad M.
    Zare H.
    Gholamhosseinian H.
    Iranian Journal of Medical Physics, 2019, 16 (01) : 34 - 40
  • [47] Impact of Very Low X-Ray Dose Levels on Imaging Quality in Electrophysiology Procedures
    Bourier, Felix
    Brost, Alexander
    Deisenhofer, Isabel
    Kolb, Christoph
    Schunkert, Heribert
    CIRCULATION, 2013, 128 (22)
  • [48] Diagnostic Reference Levels for Diagnostic and Interventional X-Ray Procedures in Germany: Update and Handling
    Schegerer, Alexander
    Loose, Reinhard
    Heuser, Lothar J.
    Brix, Gunnar
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2019, 191 (08): : 739 - 751
  • [49] PROPOSED NATIONAL DIAGNOSTIC REFERENCE LEVELS FOR STANDARD RADIOGRAPHIC X-RAY PROCEDURES IN SUDAN
    Ahmed, Nada A.
    Basheir, E. H.
    Farah, A. B.
    Mohammedzein, T. S.
    Suliman, I. I.
    RADIATION PROTECTION DOSIMETRY, 2020, 190 (04) : 419 - 426
  • [50] PLASMA + ADRENAL GLAND CORTICOSTERONE LEVELS AFTER X-RAY EXPOSURE IN RATS
    HAMEED, JMA
    HALEY, TJ
    RADIATION RESEARCH, 1964, 23 (04) : 620 - &