Exposure levels of CT and conventional X-ray procedures for radiosensitive pelvic organ in Saudi Arabia

被引:6
|
作者
Osman, Hamid [1 ]
Raafat, Bassem M. [1 ]
Faizo, Nahla L. [1 ]
Ahmed, Rania Mohammed [1 ]
Alamri, Sultan [1 ]
Alghamdi, Ahmad Joman [1 ]
Almahwasi, Ashraf [2 ,3 ]
Alharbi, M. K. M. [1 ]
Sulieman, A. [4 ]
Khandaker, Mayeen Uddin [5 ]
机构
[1] Taif Univ, Coll Appl Med Sci, Radiol Sci Dept, At Taif, Saudi Arabia
[2] Minist Interior, Med Serv, Riyadh, Saudi Arabia
[3] Taif Univ, Prince Sultan Complex, Cent Labs, Sci Res, At Taif, Saudi Arabia
[4] Prince Sattam Bin Abdulaziz Univ, Coll Appl Med Sci, Radiol & Med Imaging Dept, Alkharj, Saudi Arabia
[5] Sunway Univ, Ctr Appl Phys & Radiat Technol, Sch Engn & Technol, Bandar Sunway 47500, Malaysia
关键词
X-ray; computed tomography; pelvis radiation dose; comparison; DRLs; COMPUTED-TOMOGRAPHY SCANNERS; RADIATION-EXPOSURE;
D O I
10.1080/16878507.2021.2002005
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Radiosensitive organs in the pelvic cavity of 313 patients were exposed to low-dose diagnostic radiation to assess the entrance surface air dose (ESD) and effective doses (ED), and also to compare the X-ray and computed tomography (CT) dose levels. The patients were examined at King Abdul Aziz Specialist Hospital and King Faisal Medical Complex in Taif City, Saudi Arabia for 4 months in 2020. In conventional pelvic imaging, the DOSCAL software was used to assess the ESD. To estimate the CT radiation dose to the pelvis, the CT dose index (CTDIw, usually CTDIvol) and dose length product (DLP) were utilized. For routine pelvic X-ray imaging, the mean ESD and ED were found to be 7.2 mGy and 0.38 mSv, respectively. For CT imaging, the mean values of CTDIw, DLP, and ED were found to be 10.9 mGy, 593 mGy-cm, and 8.9 mSv, respectively. The obtained values of ESD and ED were found in agreement with the reported data available in the literature. However, a significant variation has been observed for conventional X-ray and CT doses among the selected hospitals. In comparison to conventional radiography, the CT induces 20 times higher doses to pelvic organs. The obtained results may help to establish the local diagnostic reference levels (DRLs).
引用
收藏
页码:449 / 455
页数:7
相关论文
共 50 条
  • [21] A survey on radiation exposure of primary operators from interventional X-ray procedures
    Kong, Yan
    Gao, Linfeng
    Zhuo, Weihai
    Qian, Aijun
    RADIATION MEASUREMENTS, 2013, 55 : 43 - 45
  • [22] THE VALUE OF CONVENTIONAL X-RAY DIAGNOSTIC PROCEDURES AS A FUNCTION OF THE LOCATION OF DISEASED SITE IN THE THORACIC
    SCHEEL, W
    EGER, H
    STRAUSS, HJ
    DEUTSCHE GESUNDHEITSWESEN-ZEITSCHRIFT FUR KLINISCHE MEDIZIN, 1981, 36 (14): : 585 - 589
  • [23] Radiation exposure of the Yazd population from medical conventional X-ray examinations
    Bouzarjomehri, F.
    Dashti, M. H.
    Zare, M. H.
    IRANIAN JOURNAL OF RADIATION RESEARCH, 2007, 4 (04): : 195 - 200
  • [24] Comparison of matching procedures applied on conventional x-ray images of Total Hip Arthroplasty
    Baruffaldi, F
    Bedini, R
    Cappello, A
    Toni, A
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 1198 - 1199
  • [25] EXPERIMENTAL CHANGES IN X-RAY FILTRATION FOR EMPHASIS OF TISSUE DISCRIMINATION IN CT PROCEDURES
    LEO, F
    ALBERTH, D
    NICKOLOFF, E
    MEDICAL PHYSICS, 1981, 8 (05) : 743 - 743
  • [26] X-ray CT system working on dose reduction of medical exposure
    Gotanda K.
    Seimitsu Kogaku Kaishi/Journal of the Japan Society for Precision Engineering, 2019, 85 (09): : 765 - 768
  • [27] Head injury in childhood: Comparison of sonography with the conventional x-ray and CT.
    Steiner, S
    Riebel, T
    Nazarenko, O
    Bassir, C
    Steger, W
    Vogl, T
    Felix, R
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1996, 165 (04): : 353 - 358
  • [28] Cascaded systems analysis in conventional X-ray CT: a new, objective approach
    Schegerer, A. A.
    Schlattl, H.
    Dietz, W.
    Renger, B.
    Brunner, C.
    Rummeny, E. J.
    Hoeschen, C.
    RADIATION PROTECTION DOSIMETRY, 2010, 139 (1-3) : 439 - 442
  • [29] COMPARISON OF CONVENTIONAL X-RAY WITH CT USING SASSS FOR ANKYLOSING SPONDYLITIS PATIENTS
    Lee, S. H.
    Song, R.
    Kim, S.
    Lee, Y. A.
    Hong, S. J.
    Yang, H., I
    CLINICAL AND EXPERIMENTAL RHEUMATOLOGY, 2012, 30 (04) : 631 - 631
  • [30] COMPARATIVE ASPECTS OF OCCULT INTRASACRAL MENINGOCELE WITH CONVENTIONAL X-RAY, MYELOGRAPHY AND CT