Exposure levels of CT and conventional X-ray procedures for radiosensitive pelvic organ in Saudi Arabia

被引:6
|
作者
Osman, Hamid [1 ]
Raafat, Bassem M. [1 ]
Faizo, Nahla L. [1 ]
Ahmed, Rania Mohammed [1 ]
Alamri, Sultan [1 ]
Alghamdi, Ahmad Joman [1 ]
Almahwasi, Ashraf [2 ,3 ]
Alharbi, M. K. M. [1 ]
Sulieman, A. [4 ]
Khandaker, Mayeen Uddin [5 ]
机构
[1] Taif Univ, Coll Appl Med Sci, Radiol Sci Dept, At Taif, Saudi Arabia
[2] Minist Interior, Med Serv, Riyadh, Saudi Arabia
[3] Taif Univ, Prince Sultan Complex, Cent Labs, Sci Res, At Taif, Saudi Arabia
[4] Prince Sattam Bin Abdulaziz Univ, Coll Appl Med Sci, Radiol & Med Imaging Dept, Alkharj, Saudi Arabia
[5] Sunway Univ, Ctr Appl Phys & Radiat Technol, Sch Engn & Technol, Bandar Sunway 47500, Malaysia
关键词
X-ray; computed tomography; pelvis radiation dose; comparison; DRLs; COMPUTED-TOMOGRAPHY SCANNERS; RADIATION-EXPOSURE;
D O I
10.1080/16878507.2021.2002005
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Radiosensitive organs in the pelvic cavity of 313 patients were exposed to low-dose diagnostic radiation to assess the entrance surface air dose (ESD) and effective doses (ED), and also to compare the X-ray and computed tomography (CT) dose levels. The patients were examined at King Abdul Aziz Specialist Hospital and King Faisal Medical Complex in Taif City, Saudi Arabia for 4 months in 2020. In conventional pelvic imaging, the DOSCAL software was used to assess the ESD. To estimate the CT radiation dose to the pelvis, the CT dose index (CTDIw, usually CTDIvol) and dose length product (DLP) were utilized. For routine pelvic X-ray imaging, the mean ESD and ED were found to be 7.2 mGy and 0.38 mSv, respectively. For CT imaging, the mean values of CTDIw, DLP, and ED were found to be 10.9 mGy, 593 mGy-cm, and 8.9 mSv, respectively. The obtained values of ESD and ED were found in agreement with the reported data available in the literature. However, a significant variation has been observed for conventional X-ray and CT doses among the selected hospitals. In comparison to conventional radiography, the CT induces 20 times higher doses to pelvic organs. The obtained results may help to establish the local diagnostic reference levels (DRLs).
引用
收藏
页码:449 / 455
页数:7
相关论文
共 50 条
  • [1] ESTIMATION OF THE ORGAN AND EFFECTIVE DOSE TO PATIENTS UNDERGOING MEDICAL DIAGNOSTIC X-RAY EXAMINATIONS IN SAUDI ARABIA
    Ababneh, Zaid Q.
    Almusallam, Moayed
    Alfajri, Ibrahim
    Ababneh, Anas M.
    Aljarrah, Khaled M.
    Tries, Mark A.
    Al Anazi, Nawaf
    RADIATION PROTECTION DOSIMETRY, 2021, 194 (01) : 1 - 8
  • [2] RADIATION DOSE LEVELS FOR CONVENTIONAL CHEST AND ABDOMINAL X-RAY PROCEDURES IN ELECTED HOSPITALS IN SUDAN
    Babikir, E.
    Hasan, Hussein A.
    Abdelrazig, A.
    Alkhorayef, M. A.
    Manssor, E.
    Sulieman, A.
    RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 102 - 106
  • [3] Optimization method for x-ray CT exposure
    Tsujioka, K
    Ida, Y
    Chikamatsu, H
    Goka, S
    Mori, Y
    Katada, K
    RADIOLOGY, 1996, 201 : 824 - 824
  • [4] GONADAL EXPOSURE DOSE FROM DIAGNOSTIC X-RAY PROCEDURES
    FELDMAN, A
    BABCOCK, GC
    LANIER, RR
    MORKOVIN, D
    RADIOLOGY, 1958, 71 (02) : 197 - 207
  • [5] Material discriminated X-ray CT by using conventional microfocus X-ray tube and CdTe imager
    Onishi, Y.
    Nakashima, T.
    Koike, A.
    Morii, H.
    Neo, Y.
    Mimura, H.
    Aoki, T.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 1170 - 1174
  • [6] Conventional X-ray and CT findings in a case of intraluminal choledochocele
    Catalano, O
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 169 (02): : 210 - 212
  • [7] COMPARATIVE IMAGING OF A LARYNGOCELE BY MR, CT AND CONVENTIONAL X-RAY
    VOGL, T
    SCHULER, M
    HAHN, D
    FUNK, W
    MEES, M
    DIGITALE BILDDIAGNOSTIK, 1986, 6 (02): : 64 - 66
  • [8] COMPUTED-TOMOGRAPHY FOR DIAGNOSIS OF MIDDLE-EAR-DISEASE COMPARISON OF CONVENTIONAL X-RAY PROCEDURES AND CT
    IMHOF, H
    CANIGIANI, G
    HAJEK, P
    KUMPAN, W
    SCHRATTER, H
    BRUNNER, E
    TURK, R
    RADIOLOGE, 1984, 24 (11): : 502 - 507
  • [9] Diagnostic Reference Levels for Common X-ray Procedures in Peru
    Portocarrero Bonifaz, Andres
    Camarena Rodriguez, Caterina S.
    Palma Esparza, Ricardo
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (10)
  • [10] EXPOSURE REDUCTION THROUGH QUALITY ASSURANCE FOR DIAGNOSTIC X-RAY PROCEDURES
    Lipoti, Jill A.
    HEALTH PHYSICS, 2008, 95 (05): : 577 - 585