Diagnostic accuracy of commercially available immunochromatographic rapid tests for diagnosis of dengue in India

被引:3
|
作者
Mahajan, Raman [1 ]
Nair, Mohit [1 ]
Saldanha, Ana-Maria [1 ]
Harshana, Amit [1 ]
Pereira, Alan De Lima [1 ]
Basu, Nandita [2 ]
Goswami, Rama Prasad [2 ]
Bhattacharya, Nemai [2 ]
Bandyopadhay, Bhaswati [2 ]
SenGupta, Manideepa [3 ]
Day, Moutusi [3 ]
Flevaud, Laurence [4 ]
Boelaert, Marleen [5 ]
Burza, Sakib [1 ]
机构
[1] Medecins Sans Frontieres, New Delhi, India
[2] Calcutta Sch Trop Med, Kolkata, India
[3] Med Coll & Hosp, Kolkata, India
[4] Medecins Sans Frontieres, Barcelona, Spain
[5] Inst Trop Med, Antwerp, Belgium
关键词
Dengue; diagnostic accuracy; immunochromatography; rapid diagnostic test; RDT; sensitivity; specificity; India; NS1; ANTIGEN;
D O I
10.4103/0972-9062.321747
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background & objectives: There is limited evidence regarding the accuracy of dengue rapid diagnostic kits despite their extensive use in India. We evaluated the performance of four immunochromatographic Rapid Diagnostic Test (RDTs) kits: Multisure dengue Ab/Ag rapid test (MP biomedicals; MP), Dengucheck combo (Zephyr Biomedicals; ZB), SD bioline dengue duo (Alere; SD) and Dengue day 1 test (J Mitra; JM).Methods: This is a laboratory-based diagnostic evaluation study. Rapid tests results were compared to reference non-structural (NS1) antigen or immunoglobulin M (IgM) enzyme-linked immunosorbent assay (ELISA) results of 241 dengue-positive samples and 247 dengue-negative samples. Sensitivity and specificity of NS1 and IgM components of each RDT were calculated separately and in combination (either NS1 or IgM positive) against reference standard ELISA.Results: A total of 238, 226, 208, and 146 reference NS1 ELISA samples were tested with MP, ZB, SD, and JM tests, respectively. In comparison to the NS1 ELISA reference tests, the NS1 component of MP, ZB, SD, and JM RDTs demonstrated a sensitivity of 71.8%, 85.1%, 77.2% and 80.9% respectively and specificity of 90.1%, 92.8%, 96.1 %, and 93.6%, respectively. In comparison to the IgM ELISA reference test, the IgM component of RDTs showed a sensitivity of 40.0%, 50.3%, 47.3% and 20.0% respectively and specificity of 92.4%, 88.6%, 96.5%, and 92.2% respectively. Combining NS1 antigen and IgM antibody results led to sensitivities of 87.5%, 82.9%, 93.8% and 91.7% respectively, and specificities of 75.3%, 73.9%, 76.5%, and 80.0% respectively.Interpretation & conclusion: Though specificities were acceptable, the sensitivities of each test were markedly lower than manufacturers' claims. These results also support the added value of combined antigen-and antibody-based RDTs for the diagnosis of acute dengue.
引用
收藏
页码:159 / 164
页数:6
相关论文
共 50 条
  • [21] A global comparative evaluation of commercially available rapid diagnostic tests for visceral leishmaniasis
    Cunningham, J.
    Hasker, E.
    Das, P.
    El Safi, S.
    Goto, H.
    Mondal, D.
    Mbuchi, M.
    Mukhtar, M.
    Rabello, A.
    Rijal, S.
    Sundar, S.
    Menten, J.
    Peeling, R.
    Boelaert, M.
    [J]. TROPICAL MEDICINE & INTERNATIONAL HEALTH, 2011, 16 : 180 - 180
  • [22] Prospective comparison of commercially available rapid urease tests for the diagnosis of Helicobacter pylori
    Laine, L
    Lewin, D
    Naritoku, W
    Estrada, R
    Cohen, H
    [J]. GASTROINTESTINAL ENDOSCOPY, 1996, 44 (05) : 523 - 526
  • [23] Evaluation of commercially available three dengue rapid diagnostic test kits for diagnosis of acute dengue virus infection at the point-of-care setting in Myanmar
    Kyaw, Aung Kyaw
    Tun, Mya Myat Ngwe
    Naing, Shine Thura
    Htet, Kyaw Ko Ko
    Htwe, Thein Thein
    Khaing, Yin Yin
    Mar, Tu Tu
    Aung, Thidar
    Win, Khin Nilar
    Tar, Thi
    Aye, Khin Saw
    Thant, Kyaw Zin
    Morita, Kouichi
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2019, 273
  • [24] The comparative accuracy of 8 commercial rapid immunochromatographic assays for the diagnosis of acute dengue virus infection
    Blacksell, SD
    Newton, PN
    Bell, D
    Kelley, J
    Mammen, MP
    Vaughn, DW
    Wuthiekanun, V
    Sungkakum, A
    Nisalak, A
    Day, NPJ
    [J]. CLINICAL INFECTIOUS DISEASES, 2006, 42 (08) : 1127 - 1134
  • [25] Commercially available rapid diagnostic tests for the detection of high priority pathogens: status and challenges
    Castillo-Leon, Jaime
    Trebbien, Ramona
    Castillo, John J.
    Svendsen, Winnie E.
    [J]. ANALYST, 2021, 146 (12) : 3750 - 3776
  • [26] Accuracy and utility of commercially available amplification and serologic tests for the diagnosis of minimal pulmonary tuberculosis
    Al Zahrani, K
    Al Jahdali, H
    Poirier, L
    René, P
    Gennaro, ML
    Menzies, D
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2000, 162 (04) : 1323 - 1329
  • [27] Comparison of five commercially available immunochromatographic tests for the detection of norovirus in faecal specimens
    Vyas, K.
    Atkinson, C.
    Clark, D. A.
    Irish, D.
    [J]. JOURNAL OF HOSPITAL INFECTION, 2015, 91 (02) : 176 - 178
  • [28] The diagnostic accuracy of commercially available automated external defibrillators
    Nishiyama, T.
    Katsumata, Y.
    Kimura, T.
    Nishiyama, N.
    Tanimoto, Y.
    Aizawa, Y.
    Mitamura, H.
    Fukuda, K.
    Takatsuki, S.
    [J]. EUROPEAN HEART JOURNAL, 2014, 35 : 771 - 772
  • [29] Diagnostic Accuracy of Commercially Available Automated External Defibrillators
    Nishiyama, Takahiko
    Nishiyama, Ako
    Negishi, Masachika
    Kashimura, Shin
    Katsumata, Yoshinori
    Kimura, Takehiro
    Nishiyama, Nobuhiro
    Tanimoto, Yoko
    Aizawa, Yoshiyasu
    Mitamura, Hideo
    Fukuda, Keiichi
    Takatsuki, Seiji
    [J]. JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2015, 4 (12):
  • [30] Diagnostic accuracy of antigen-based immunochromatographic rapid diagnostic tests for the detection of Salmonella in blood culture broth
    Kuijpers, Laura M. F.
    Chung, Panha
    Peeters, Marjan
    Phoba, Marie-France
    Kham, Chun
    Barbe, Barbara
    Lunguya, Octavie
    Jacobs, Jan
    [J]. PLOS ONE, 2018, 13 (03):