Numerical Investigation on Auxiliary Heat Sources for Horizontal Ground Heat Exchangers

被引:2
|
作者
Bulmez, Alexandru-Mihai [1 ]
Ciofoaia, Vasile [1 ]
Nastase, Gabriel [1 ]
Dragomir, George [1 ]
Brezeanu, Alin-Ionut [1 ]
Iordan, Nicolae-Fani [1 ]
Bolocan, Sorin-Ionut [1 ]
Fratu, Mariana [1 ]
Plescan, Costel [1 ]
Cazacu, Christiana Emilia [1 ]
Deaconu, Ovidiu [1 ]
机构
[1] Transilvania Univ Brasov, Fac Civil Engn, Dept Bldg Serv, Brasov 500152, Romania
关键词
horizontal ground heat exchanger; auxiliary heat source; heated basement; solar thermal panel; ground freezing period; ground temperature; THERMAL PERFORMANCE; SIMULATION; DESIGN;
D O I
10.3390/buildings12081259
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Human interference with the Earth's climate cannot be ignored any longer. Renewable energy sources need utmost attention in all energy sectors. For buildings, geothermal energy for heating, cooling, and domestic hot water is a sustainable solution. Horizontal ground heat exchangers (HGHE) demonstrate promising results with low installation costs. Research is focused on increasing their thermal performances by structural improvements and ground thermal proprieties improvements, with little research on using auxiliary heat to increase their performances. A numerical model for an HGHE was established to investigate the effects of auxiliary heat sources on the performances of the HGHE. The results demonstrate that heat transfer into the HGHE increases the overall ground temperature at the end of the heating season by 138.50% compared with no heat transfer from auxiliary heat sources. The ground freezing period decreased by approximately 24.74% by having a heated basement, approximately 40.20% by transferring heat with solar thermal panels, and approximately 62.88% by using both auxiliary heat sources. The difference between the undisturbed ground temperature and the ground temperature with no auxiliary heat sources at the end of the season was 3.45 degrees C. The difference between the undisturbed ground temperature and the ground temperature with all auxiliary heat sources resulted in 0.92 degrees C.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] The ground surface energy balance in modelling horizontal ground heat exchangers
    Bortoloni, Marco
    Bottarelli, Michele
    Su, Yuehong
    [J]. 34TH UIT HEAT TRANSFER CONFERENCE 2016, 2017, 796
  • [22] Parametric investigation of helical ground heat exchangers for heat pump applications
    Dehghan, Babak
    Sisman, Altug
    Aydin, Murat
    [J]. ENERGY AND BUILDINGS, 2016, 127 : 999 - 1007
  • [23] Experimental measurement and numerical simulation of horizontal-coupled slinky ground source heat exchangers
    Wu, Yupeng
    Gan, Guohui
    Verhoef, Anne
    Vidale, Pier Luigi
    Gonzalez, Raquel Garcia
    [J]. APPLIED THERMAL ENGINEERING, 2010, 30 (16) : 2574 - 2583
  • [24] Modeling and assessment of the efficiency of horizontal and vertical ground heat exchangers
    Florides, G.
    Theofanous, E.
    Iosif-Stylianou, I.
    Tassou, S.
    Christodoulides, P.
    Zomeni, Z.
    Tsiolakis, E.
    Kalogirou, S.
    Messaritis, V.
    Pouloupatis, P.
    Panayiotou, G.
    [J]. ENERGY, 2013, 58 : 655 - 663
  • [25] Factors Influencing the Thermal Efficiency of Horizontal Ground Heat Exchangers
    Di Sipio, Eloisa
    Bertermann, David
    [J]. ENERGIES, 2017, 10 (11):
  • [26] Impact of soil heterogeneity on the functioning of horizontal ground heat exchangers
    Simms, Richard B.
    Haslam, Simon R.
    Craig, James R.
    [J]. GEOTHERMICS, 2014, 50 : 35 - 43
  • [27] NUMREICAL ANALYSIS OF SYSTEMS WITH VAPOUR COMPRESSOR HEAT PUMPS AND HORIZONTAL GROUND HEAT EXCHANGERS
    Hanuszkiewicz-Drapala, Malgorzata
    [J]. RYNEK ENERGII, 2010, (05): : 82 - 88
  • [28] Investigating the Thermal Performance of Horizontal Slinky Ground Heat Exchangers for Geothermal Heat Pump
    Cui, Ping
    Yang, Jie
    Lin, Yun
    Fang, Zhaohong
    [J]. PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 2: HVAC&R COMPONENT AND ENERGY SYSTEM, 2014, 262 : 73 - 83
  • [29] Artificial neural networks for predicting the performance of heat pumps with horizontal ground heat exchangers
    Zhou, Yu
    Narsilio, Guillermo
    Makasis, Nikolas
    Soga, Kenichi
    Chen, Peng
    Aye, Lu
    [J]. FRONTIERS IN ENERGY RESEARCH, 2024, 12
  • [30] Numerical Investigation on Energy Efficiency of Heat Pump with Tunnel Lining Ground Heat Exchangers under Building Cooling
    Liu, Xiaohua
    Li, Chenglin
    Zhang, Guozhu
    Zhang, Linfeng
    Wei, Bin
    [J]. BUILDINGS, 2021, 11 (12)