Amlodipine;
Recovery;
Repeatability;
Precision;
Reversed phase high performance liquid chromatography;
Validation;
HUMAN PLASMA;
BESYLATE;
ELECTROPHORESIS;
FORMULATIONS;
VALSARTAN;
DRUG;
D O I:
10.4314/tjpr.v14i4.15
中图分类号:
R9 [药学];
学科分类号:
1007 ;
摘要:
Purpose: To develop and validate a new sensitive and low-cost method for the analysis of amlodipine in tablet dosage form using reversed phase high performance liquid chromatography (RP-HPLC) with ultraviolet (UV) detection. Methods: Standards and samples were prepared by dissolving amlodipine besylate standard or amlodipine tablets in mobile phase and sonicated for 5 min. The samples were analysed by RP-HPLC equipped with quaternary pump and auto-injector. Separation was achieved using C18 column, and the mobile phase consisted of ammonium acetate buffer containing 0.02 % triethylamine TEA (pH = 4, adjusted using glacial acetic acid) and acetonitrile in the ratio 60: 40 v/v. The flow rate was 1 ml/min and a UV detector was used for the detection of amlodipine at a wavelength of 248 nm. The method was validated according to International Conference of Harmonization (ICH) guidelines. Results: The retention time for amlodipine peak was 3.44 +/- 0.41 min with a total run time of 6 min. The method was linear over the range of 0.5 - 40 mu g/ml with coefficient of determination (R-2) of 0.999. Recovery was 98.09 - 100.19 %, and the method showed high precision and repeatability. All validated parameters were within the range of ICH requirements. Conclusion: A new rapid sensitive and low-cost method has been developed and validated for the analysis of amlodipine in tablet dosage form.