Feasibility of SPECT myocardial perfusion imaging in the super-obese using a multi-head semiconductor camera with attenuation correction

被引:3
|
作者
DeCicco, Anthony E. [1 ]
Sokil, Alexis B. [2 ]
Marhefka, Gregary D. [2 ]
Reist, Kirk [2 ]
Hansen, Christopher L. [2 ]
机构
[1] Thomas Jefferson Univ, Dept Internal Med, Philadelphia, PA 19107 USA
[2] Thomas Jefferson Univ, Jefferson Heart Inst, Philadelphia, PA 19107 USA
关键词
Obesity; myocardial perfusion imaging; multi-head camera; CORONARY-ARTERY-DISEASE; GATED SPECT; RISK; PREVALENCE; OVERWEIGHT; ACCURACY; STRESS; TL-201;
D O I
10.1007/s12350-014-0018-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Obesity is not only associated with an increased risk of coronary artery disease, but also decreases the accuracy of many diagnostic modalities pertinent to this disease. Advances in myocardial perfusion imaging (MPI) have mitigated somewhat the effects of obesity, although the feasibility of MPI in the super-obese (defined as a BMI > 50) is currently untested. We undertook this study to assess the practicality of MPI in the super-obese using a multi-headed solid-state gamma camera with attenuation correction. We retrospectively identified consecutive super-obese patients referred for MPI at our institution. The images were interpreted by 3 blinded, experienced readers and graded for quality and diagnosis, and subjectively evaluated the contribution of attenuation correction. Clinical follow-up was obtained from review of medical records. 72 consecutive super-obese patients were included. Their BMI ranged from 50 to 67 (55.7 +/- A 5.1). Stress image quality was considered good or excellent in 45 (63%), satisfactory in 24 (33%), poor in 3 (4%), and uninterpretable in 0 patients. Rest images were considered good or excellent in 34 (49%), satisfactory in 23 (33%), poor in 13 (19%), and uninterpretable in 0 patients. Attenuation correction changed the interpretation in 34 (47%) of studies. MPI is feasible and provides acceptable image quality for super-obese patients, although it may be camera and protocol dependent.
引用
收藏
页码:344 / 350
页数:7
相关论文
共 50 条
  • [31] Impact of attenuation correction and gated acquisition in SPECT myocardial perfusion imaging: results of the multicentre SPAG (SPECT Attenuation Correction vs Gated) study
    Genovesi, Dario
    Giorgetti, Assuero
    Gimelli, Alessia
    Kusch, Annette
    Tagliavia, Irene D'Aragona
    Casagranda, Mirta
    Cannizzaro, Giorgio
    Giubbini, Raffaele
    Bertagna, Francesco
    Fagioli, Giorgio
    Rossi, Massimiliano
    Romeo, Annadina
    Bertolaccini, Pietro
    Bonini, Rita
    Marzullo, Paolo
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (10) : 1890 - 1898
  • [32] Impact of attenuation correction and gated acquisition in SPECT myocardial perfusion imaging: results of the multicentre SPAG (SPECT Attenuation Correction vs Gated) study
    Dario Genovesi
    Assuero Giorgetti
    Alessia Gimelli
    Annette Kusch
    Irene D’Aragona Tagliavia
    Mirta Casagranda
    Giorgio Cannizzaro
    Raffaele Giubbini
    Francesco Bertagna
    Giorgio Fagioli
    Massimiliano Rossi
    Annadina Romeo
    Pietro Bertolaccini
    Rita Bonini
    Paolo Marzullo
    European Journal of Nuclear Medicine and Molecular Imaging, 2011, 38 : 1890 - 1898
  • [33] Attenuation correction for myocardial perfusion imaging - A comparison between SPECT and PET imaging by polar map analysis
    Graf, S.
    Khorsand, A.
    Stix, G.
    Nekolla, S.
    Becherer, A.
    Kletter, K.
    Dudczak, R.
    Sochor, H.
    Maurer, G.
    Parenta, G.
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2006, 45 (04): : 171 - 176
  • [34] Value of respiratory and patient motion correction in myocardial perfusion imaging using a CZT-based SPECT camera
    Van Dijk, Joris
    Dalen, Jorn
    Mouden, Mohamed
    Ottervanger, Jan Paul
    Knollema, Siert
    Slump, Cornelis
    Jager, Pieter
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [35] Deep learning approach using SPECT-to-PET translation for attenuation correction in CT-less myocardial perfusion SPECT imaging
    Kawakubo, Masateru
    Nagao, Michinobu
    Kaimoto, Yoko
    Nakao, Risako
    Yamamoto, Atsushi
    Kawasaki, Hiroshi
    Iwaguchi, Takafumi
    Matsuo, Yuka
    Kaneko, Koichiro
    Sakai, Akiko
    Sakai, Shuji
    ANNALS OF NUCLEAR MEDICINE, 2024, 38 (03) : 199 - 209
  • [36] Impact of attenuation correction on polar map analysis of myocardial perfusion imaging by PET and SPECT.
    Graf, S
    Khorsand, A
    Leitinger, I
    Stix, G
    Becherer, A
    Kletter, K
    Dudczak, R
    Sochor, H
    Maurer, G
    Porenta, G
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 90P - 90P
  • [37] Deep learning approach using SPECT-to-PET translation for attenuation correction in CT-less myocardial perfusion SPECT imaging
    Masateru Kawakubo
    Michinobu Nagao
    Yoko Kaimoto
    Risako Nakao
    Atsushi Yamamoto
    Hiroshi Kawasaki
    Takafumi Iwaguchi
    Yuka Matsuo
    Koichiro Kaneko
    Akiko Sakai
    Shuji Sakai
    Annals of Nuclear Medicine, 2024, 38 : 199 - 209
  • [38] The diagnostic utility of attenuation correction of spect myocardial perfusion imaging for the detection of LAD disease.
    Bhatti, TK
    DePasquale, EE
    Nody, AC
    Kesanakurthy, S
    Panagopoulos, G
    Coplan, NC
    JOURNAL OF INVESTIGATIVE MEDICINE, 2006, 54 (01) : S303 - S303
  • [39] Deep learning-guided attenuation correction in the image domain for myocardial perfusion SPECT imaging
    Mostafapour, Samaneh
    Gholamiankhah, Faeze
    Maroufpour, Sirwan
    Momennezhad, Mehdi
    Asadinezhad, Mohsen
    Zakavi, Seyed Rasoul
    Arabi, Hossein
    Zaidi, Habib
    JOURNAL OF COMPUTATIONAL DESIGN AND ENGINEERING, 2022, 9 (02) : 434 - 447
  • [40] Clinical Utility of CT-based Attenuation-correction in Myocardial Perfusion SPECT Imaging
    Hatipoglu, Filiz
    Cetin, Neslihan
    MOLECULAR IMAGING AND RADIONUCLIDE THERAPY, 2023, 32 (02) : 138 - 145