Feasibility of SPECT myocardial perfusion imaging in the super-obese using a multi-head semiconductor camera with attenuation correction

被引:3
|
作者
DeCicco, Anthony E. [1 ]
Sokil, Alexis B. [2 ]
Marhefka, Gregary D. [2 ]
Reist, Kirk [2 ]
Hansen, Christopher L. [2 ]
机构
[1] Thomas Jefferson Univ, Dept Internal Med, Philadelphia, PA 19107 USA
[2] Thomas Jefferson Univ, Jefferson Heart Inst, Philadelphia, PA 19107 USA
关键词
Obesity; myocardial perfusion imaging; multi-head camera; CORONARY-ARTERY-DISEASE; GATED SPECT; RISK; PREVALENCE; OVERWEIGHT; ACCURACY; STRESS; TL-201;
D O I
10.1007/s12350-014-0018-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Obesity is not only associated with an increased risk of coronary artery disease, but also decreases the accuracy of many diagnostic modalities pertinent to this disease. Advances in myocardial perfusion imaging (MPI) have mitigated somewhat the effects of obesity, although the feasibility of MPI in the super-obese (defined as a BMI > 50) is currently untested. We undertook this study to assess the practicality of MPI in the super-obese using a multi-headed solid-state gamma camera with attenuation correction. We retrospectively identified consecutive super-obese patients referred for MPI at our institution. The images were interpreted by 3 blinded, experienced readers and graded for quality and diagnosis, and subjectively evaluated the contribution of attenuation correction. Clinical follow-up was obtained from review of medical records. 72 consecutive super-obese patients were included. Their BMI ranged from 50 to 67 (55.7 +/- A 5.1). Stress image quality was considered good or excellent in 45 (63%), satisfactory in 24 (33%), poor in 3 (4%), and uninterpretable in 0 patients. Rest images were considered good or excellent in 34 (49%), satisfactory in 23 (33%), poor in 13 (19%), and uninterpretable in 0 patients. Attenuation correction changed the interpretation in 34 (47%) of studies. MPI is feasible and provides acceptable image quality for super-obese patients, although it may be camera and protocol dependent.
引用
收藏
页码:344 / 350
页数:7
相关论文
共 50 条
  • [21] Value of attenuation correction in stress-only myocardial perfusion imaging using CZT-SPECT
    J. D. van Dijk
    M. Mouden
    J. P. Ottervanger
    J. A. van Dalen
    S. Knollema
    C. H. Slump
    P. L. Jager
    Journal of Nuclear Cardiology, 2017, 24 : 395 - 401
  • [22] Value of attenuation correction in stress-only myocardial perfusion imaging using CZT-SPECT
    van Dijk, J. D.
    Mouden, M.
    Ottervanger, J. P.
    van Dalen, J. A.
    Knollema, S.
    Slump, C. H.
    Jager, P. L.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (02) : 395 - 401
  • [23] Evaluation of data acquisition geometries and strategies for multi-head SPECT systems for myocardial SPECT imaging.
    Qi, YJ
    Gilland, KL
    Tsui, BM
    Frey, EC
    Gullberg, GT
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 278P - 278P
  • [24] Clinical value of supine and upright myocardial perfusion imaging in obese patients using the D-SPECT camera
    Simona Ben-Haim
    Omar Almukhailed
    Johanne Neill
    Piotr Slomka
    Rayjanah Allie
    Dalia Shiti
    Daniel S. Berman
    Jamshed Bomanji
    Journal of Nuclear Cardiology, 2014, 21 : 478 - 485
  • [25] Clinical value of supine and upright myocardial perfusion imaging in obese patients using the D-SPECT camera
    Ben-Haim, Simona
    Almukhailed, Omar
    Neill, Johanne
    Slomka, Piotr
    Allie, Rayjanah
    Shiti, Dalia
    Berman, Daniel S.
    Bomanji, Jamshed
    JOURNAL OF NUCLEAR CARDIOLOGY, 2014, 21 (03) : 478 - 485
  • [26] Correction of photon attenuation in SPECT myocardial perfusion imaging: Preliminary results of a multicenter trial
    Hendel, RC
    Kiat, H
    Follansbee, WP
    Heller, GV
    Cullom, SJ
    Berman, DS
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 811 - 811
  • [27] Improved Outcome Prediction by SPECT Myocardial Perfusion Imaging After CT Attenuation Correction
    Pazhenkottil, Aju P.
    Ghadri, Jelena-Rima
    Nkoulou, Rene N.
    Wolfrum, Mathias
    Buechel, Ronny R.
    Kueest, Silke M.
    Husmann, Lars
    Herzog, Bernhard A.
    Gaemperli, Oliver
    Kaufmann, Philipp A.
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (02) : 196 - 200
  • [28] Analysis of the influence of CT attenuation correction on IQ-SPECT myocardial perfusion imaging
    Xue, Jidi
    Li, Sijin
    Zhang, Lei
    Wu, Zhifang
    Hu, Guang
    Wang, Yuetao
    Wei, Hua
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [29] Attenuation correction in SPECT-Myocardial perfusion imaging:It can be corrected, but is it really useful?
    Abhilash, S.
    Jeevan, S.
    Pradeep, P.
    Sarath, S.
    Manishi, L. N.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S608 - S608
  • [30] Effects of CT attenuation correction and reconstruction method on myocardial SPECT perfusion imaging.
    Naum, A. G.
    Biermann, M.
    Johnsen, B.
    Husby, J. Aase
    Bach-Gansmo, T.
    Rotevatn, S.
    Nordrehaug, J. E.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S285 - S286