Simultaneous multi-slice (SMS) acquisition enhances the sensitivity of hemodynamic mapping using gas challenges

被引:8
|
作者
Ravi, Harshan [1 ,2 ,3 ]
Liu, Peiying [1 ,2 ]
Peng, Shin-Lei [1 ,2 ,4 ]
Liu, Hanli [3 ]
Lu, Hanzhang [1 ,2 ]
机构
[1] Johns Hopkins Univ, Dept Radiol, Baltimore, MD USA
[2] UT Southwestern Med Ctr, Adv Imaging Res Ctr, Dallas, TX USA
[3] Univ Texas Arlington, Dept Bioengn, Arlington, TX 76019 USA
[4] China Med Univ, Dept Biomed Imaging & Radiol Sci, Taichung, Taiwan
基金
美国国家卫生研究院;
关键词
brain; cerebrovascular reactivity; CO2; gas inhalation; MRI; SMS; CEREBRAL-BLOOD-FLOW; CAROTID-ARTERY STENOSIS; IMPAIRED CEREBROVASCULAR REACTIVITY; EMISSION COMPUTED-TOMOGRAPHY; TEST-RETEST RELIABILITY; END-TIDAL CO2; OCCLUSIVE DISEASE; MOYAMOYA-DISEASE; CARBON-DIOXIDE; CALIBRATED MRI;
D O I
10.1002/nbm.3600
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Hemodynamic mapping using gas inhalation has received increasing interest in recent years. Cerebrovascular reactivity (CVR), which reflects the ability of the brain vasculature to dilate in response to a vasoactive stimulus, can be measured by CO2 inhalation with continuous acquisition of blood oxygen level-dependent (BOLD) magnetic resonance images. Cerebral blood volume (CBV) can be measured by O-2 inhalation. These hemodynamic mapping methods are appealing because of their absence of gadolinium contrast agent, their ability to assess both baseline perfusion and vascular reserve, and their utility in calibrating the functional magnetic resonance imaging (fMRI) signal. However, like other functional and physiological indices, a major drawback of these measurements is their poor sensitivity and reliability. Simultaneous multi-slice echo planar imaging (SMS EPI) is a fast imaging technology that allows the excitation and acquisition of multiple two-dimensional slices simultaneously, and has been shown to enhance the sensitivity of several MRI applications. To our knowledge, the benefit of SMS in gas inhalation imaging has not been investigated. In this work, we compared the sensitivity of CO2 and O-2 inhalation data collected using SMS factor 2 (SMS2) and SMS factor 3 (SMS3) with those collected using conventional EPI (SMS1). We showed that the sensitivity of SMS scans was significantly (p=0.01) higher than that of conventional EPI, although no difference was found between SMS2 and SMS3 (p=0.3). On a voxel-wise level, approximately 20-30% of voxels in the brain showed a significant enhancement in sensitivity when using SMS compared with conventional EPI, with other voxels showing an increase, but not reaching statistical significance. When using SMS, the scan duration can be reduced by half, whilst maintaining the sensitivity of conventional EPI. The availability of a sensitive acquisition technique can further enhance the potential of gas inhalation MRI in clinical applications.
引用
收藏
页码:1511 / 1518
页数:8
相关论文
共 50 条
  • [21] Simultaneous multi-slice MR imaging of the hip at 3 T to reduce acquisition times and maintain image quality
    Mayuko Haraikawa
    Masashi Suzuki
    Kaiji Inoue
    Eito Kozawa
    Junji Tanaka
    Mamoru Niitsu
    BMC Musculoskeletal Disorders, 19
  • [22] Clinical application of Half Fourier Acquisition Single Shot Turbo Spin Echo (HASTE) imaging accelerated by simultaneous multi-slice acquisition
    Schulz, Jenni
    Marques, Jose P.
    ter Telgte, Annemieke
    van Dorst, Anouk
    de Leeuw, Frank-Erik
    Meijer, Frederick J. A.
    Norris, David G.
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 98 : 200 - 206
  • [23] Simultaneous multi-slice image reconstruction using regularized image domain split slice-GRAPPA for diffusion MRI
    HashemizadehKolowri, Sk
    Chen, Rong-Rong
    Adluru, Ganesh
    Dean, Douglas C.
    Wilde, Elisabeth A.
    Alexander, Andrew L.
    DiBella, Edward V. R.
    MEDICAL IMAGE ANALYSIS, 2021, 70
  • [24] Fast MR thermometry using an echo-shifted sequence with simultaneous multi-slice imaging
    Peng, Yuhong
    Zou, Chao
    Qiao, Yangzi
    Tie, Changjun
    Wan, Qian
    Jiang, Rui
    Cheng, Chuanli
    Liang, Dong
    Zheng, Hairong
    Li, Faqi
    Liu, Xin
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2018, 31 (06) : 771 - 779
  • [25] Accelerating joint relaxation-diffusion MRI by integrating time division multiplexing and simultaneous multi-slice (TDM-SMS) strategies
    Ji, Yang
    Hoge, W. Scott
    Gagoski, Borjan
    Westin, Carl-Fredrik
    Rathi, Yogesh
    Ning, Lipeng
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (06) : 2697 - 2709
  • [26] Accelerated Simultaneous Multi-Slice MRI using Subject-Specific Convolutional Neural Networks
    Zhang, Chi
    Moeller, Steen
    Weingaertner, Sebastian
    Ugurbil, Kamil
    Akcakaya, Mehmet
    2018 CONFERENCE RECORD OF 52ND ASILOMAR CONFERENCE ON SIGNALS, SYSTEMS, AND COMPUTERS, 2018, : 1636 - 1640
  • [27] Fast MR thermometry using an echo-shifted sequence with simultaneous multi-slice imaging
    Yuhong Peng
    Chao Zou
    Yangzi Qiao
    Changjun Tie
    Qian Wan
    Rui Jiang
    Chuanli Cheng
    Dong Liang
    Hairong Zheng
    Faqi Li
    Xin Liu
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2018, 31 : 771 - 779
  • [28] Simultaneous multi-slice MR imaging of the hip at 3T to reduce acquisition times and maintain image quality
    Haraikawa, Mayuko
    Suzuki, Masashi
    Inoue, Kaiji
    Kozawa, Eito
    Tanaka, Junji
    Niitsu, Mamoru
    BMC MUSCULOSKELETAL DISORDERS, 2018, 19
  • [29] Abdominal Diffusion-Weighted MRI With Simultaneous Multi-Slice Acquisition: Agreement and Reproducibility of Apparent Diffusion Coefficients Measurements
    Ye, Zheng
    Yao, Shan
    Yang, Ting
    Li, Qing
    Li, Zhenlin
    Song, Bin
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 59 (04) : 1170 - 1178
  • [30] In vivo multi-slice mapping of myelin water content using T2* decay
    Hwang, Dosik
    Kim, Dong-Hyun
    Du, Yiping P.
    NEUROIMAGE, 2010, 52 (01) : 198 - 204