A model for adjustment of differential gravity measurements with simultaneous gravimeter calibration

被引:6
|
作者
Dias, FJSS
Escobar, IP
机构
[1] Observ Nacl, Dept Geofis, BR-20921400 Rio De Janeiro, Brazil
[2] Univ Estado Rio de Janeiro, Dept Engn Cartog, BR-20559900 Rio De Janeiro, Brazil
关键词
calibration; gravimeter;
D O I
10.1007/s001900100168
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
A mathematical model is proposed for adjustment of differential or relative gravity measurements, involving simultaneously instrumental readings, coefficients of the calibration function, and gravity values of selected base stations. Tests were performed with LaCoste and Romberg model G gravimeter measurements for a set of base stations located along a north-south line with 1750 mGal gravity range. This line was linked to nine control stations, where absolute gravity values had been determined by the free-fall method, with an accuracy better than 10 mu Gal, The model shows good consistence and stability. Results show the possibility of improving the calibration functions of gravimeters, as well as a better estimation of the gravity values, due to the flexibility admitted to the values of the calibration coefficients.
引用
收藏
页码:151 / 156
页数:6
相关论文
共 50 条
  • [41] Tweaking model parameters: Manual adjustment and self calibration
    Schulz, B
    Tuffs, RJ
    Laureijs, RJ
    Lu, N
    Peschke, SB
    Gabriel, C
    Khan, I
    PROCEEDINGS OF THE WORKSHOP ON P32 OVERSAMPLED MAPPING - ISOPHOT, 2002, 482 : 21 - 23
  • [42] A new procedure to perform differential underground gravity measurements
    Ranieri, G
    Sambuelli, L
    JOURNAL OF APPLIED GEOPHYSICS, 1996, 36 (2-3) : 123 - 129
  • [43] Design and model of calibration for chemical measurements
    L. Brüggemann
    R. Wennrich
    Accreditation and Quality Assurance, 2008, 13 : 567 - 573
  • [44] Design and model of calibration for chemical measurements
    Brueggemann, L.
    Wennrich, R.
    ACCREDITATION AND QUALITY ASSURANCE, 2008, 13 (10) : 567 - 573
  • [45] Calibration of Integral Magnetometer Linear Model Coefficients Using Simultaneous Measurements of a Three-Axis Gyro
    Vasilyuk N.N.
    Gyroscopy and Navigation, 2019, 10 (2) : 99 - 110
  • [46] Gravity measurements in southeastern Alaska reveal negative gravity rate of change caused by glacial isostatic adjustment
    Sun, W.
    Miura, S.
    Sato, T.
    Sugano, T.
    Freymueller, J.
    Kaufman, M.
    Larsen, C. F.
    Cross, R.
    Inazu, D.
    JOURNAL OF GEOPHYSICAL RESEARCH-SOLID EARTH, 2010, 115
  • [47] GRAVITY MEASUREMENTS ON NORTH AMERICAN CALIBRATION LINE WITH CANADIAN PENDULUM APPARATUS
    VALLIANT, HD
    TRANSACTIONS-AMERICAN GEOPHYSICAL UNION, 1969, 50 (02): : 57 - &
  • [48] GRAVITY MEASUREMENTS ON NORTH AMERICAN CALIBRATION LINE WITH CANADIAN PENDULUM APPARATUS
    VALLIANT, HD
    GEOPHYSICAL JOURNAL OF THE ROYAL ASTRONOMICAL SOCIETY, 1969, 17 (05): : 489 - &
  • [49] Calibration of parameters for a combined gravity and traffic assignment model
    Han, R
    PROGRESS IN OPTIMIZATION: CONTRIBUTIONS FROM AUSTRALASIA, 2000, 39 : 287 - 303
  • [50] methylDMV: SIMULTANEOUS DETECTION OF DIFFERENTIAL DNA METHYLATION AND VARIABILITY WITH CONFOUNDER ADJUSTMENT
    Kuan, Pei Fen
    Song, Junyan
    He, Shuyao
    PACIFIC SYMPOSIUM ON BIOCOMPUTING 2017, 2017, : 461 - 472