A model for adjustment of differential gravity measurements with simultaneous gravimeter calibration

被引:6
|
作者
Dias, FJSS
Escobar, IP
机构
[1] Observ Nacl, Dept Geofis, BR-20921400 Rio De Janeiro, Brazil
[2] Univ Estado Rio de Janeiro, Dept Engn Cartog, BR-20559900 Rio De Janeiro, Brazil
关键词
calibration; gravimeter;
D O I
10.1007/s001900100168
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
A mathematical model is proposed for adjustment of differential or relative gravity measurements, involving simultaneously instrumental readings, coefficients of the calibration function, and gravity values of selected base stations. Tests were performed with LaCoste and Romberg model G gravimeter measurements for a set of base stations located along a north-south line with 1750 mGal gravity range. This line was linked to nine control stations, where absolute gravity values had been determined by the free-fall method, with an accuracy better than 10 mu Gal, The model shows good consistence and stability. Results show the possibility of improving the calibration functions of gravimeters, as well as a better estimation of the gravity values, due to the flexibility admitted to the values of the calibration coefficients.
引用
收藏
页码:151 / 156
页数:6
相关论文
共 50 条
  • [31] Fast data acquisition and analysis of gravity datum : A case study in reconstruction of gravity basic network and relative gravimeter calibration baselines in Guangxi
    Wang LinSong
    Ma Xian
    Chen Chao
    Li HaiLong
    Mo YaJun
    Wang LiMin
    Liu YiMing
    CHINESE JOURNAL OF GEOPHYSICS-CHINESE EDITION, 2019, 62 (05): : 1885 - 1897
  • [32] Gravity measurements as a calibration tool for geothermal reservoir modelling
    Pearson-Grant, S. C.
    Franz, P.
    Clearwater, J.
    GEOTHERMICS, 2018, 73 : 146 - 157
  • [33] THE 1987 SOUTHEASTERN ALASKA GRAVITY CALIBRATION RANGE - ABSOLUTE AND RELATIVE GRAVITY MEASUREMENTS
    SASAGAWA, GS
    ZUMBERGE, MA
    STEVENSON, JM
    LAUTZENHISER, T
    WIRTZ, J
    ANDER, ME
    JOURNAL OF GEOPHYSICAL RESEARCH-SOLID EARTH AND PLANETS, 1989, 94 (B6): : 7661 - 7666
  • [34] Gravity measurements with a portable absolute gravimeter A10 in Syowa Station and Langhovde, East Antarctica
    Kazama, Takahito
    Hayakawa, Hideaki
    Higashi, Toshihiro
    Ohsono, Shingo
    Iwanami, Shunsuke
    Hanyu, Tomoko
    Ohta, Harumi
    Doi, Koichiro
    Aoyama, Yuichi
    Fukuda, Yoichi
    Nishijima, Jun
    Shibuya, Kazuo
    POLAR SCIENCE, 2013, 7 (3-4) : 260 - 277
  • [35] Experiment with simultaneous measurements at two optical wavelengths in the FG5X absolute gravimeter
    Kren, Petr
    Palinkas, Vojtech
    Hald, Jan
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2024, 35 (03)
  • [36] DIFFERENTIAL SCANNING CALORIMETRY - SIMULTANEOUS TEMPERATURE AND CALORIMETRIC CALIBRATION
    EYSEL, W
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1983, 185 (MAR): : 5 - ANYL
  • [37] High-precision piezoelectric gravimeter of automated aviation gravimetric system for measurements of anomalies of gravity acceleration
    Bezvesilna, E. N.
    Tkachuk, A. G.
    Voytsitskiy, M. A.
    GEOFIZICHESKIY ZHURNAL-GEOPHYSICAL JOURNAL, 2015, 37 (04): : 139 - 144
  • [38] Combined Use of a Superconducting Gravimeter and Scintrex Gravimeters for Hydrological Correction of Precise Gravity Measurements: A Superhybrid Gravimetry
    Earthquake Research Institute, The University of Tokyo, Bunkyo
    Tokyo, Japan
    不详
    Ibaraki, Japan
    不详
    Iwate, Japan
    不详
    Ibaraki, Japan
    不详
    Yamanashi, Japan
    不详
    Aichi, Japan
    不详
    Kochi, Japan
    International Association of Geodesy Symposia, (71-76):
  • [39] THE GRAVITY MODEL: AN ILLUSTRATION OF STRUCTURAL ESTIMATION AS CALIBRATION
    Balistreri, Edward J.
    Hillberry, Russell H.
    ECONOMIC INQUIRY, 2008, 46 (04) : 511 - 527
  • [40] A New Model of Bundle Adjustment Used in Camera Calibration