On the cause of spatial displacement of long T1 species in segmented inversion recovery prepared imaging

被引:4
|
作者
Goldfarb, JW
Arnold, S
Schapiro, W
Reichek, N
机构
[1] St Francis Hosp, Dept Res & Educ, DeMatteis MRI, Roslyn, NY 11576 USA
[2] SUNY Stony Brook, Program Biomed Engn, Stony Brook, NY 11794 USA
[3] SUNY Stony Brook, Dept Cardiol, Stony Brook, NY 11794 USA
关键词
D O I
10.1002/mrm.20566
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Using inversion recovery steady-state free precession segmented k-space imaging for the detection of myocardial infarction, we noticed that some structures appeared in the wrong locations of the image. In this work, the spatial displacement is demonstrated and explained from both theoretical and experimental points of view. The effect is due to a change in phase from segment to segment of the detected magnetization from species with long T-1's such as cysts, fluid collections, and cerebrospinal fluid. Depending on the number of k-space segments and view ordering, structures can be replicated throughout the image or displaced by half of the phase-encoding field of view.
引用
收藏
页码:481 / 485
页数:5
相关论文
共 50 条
  • [21] T1 mapping of myocardium using inversion recovery cine at 3.0T
    Yanjie Zhu
    Yinzhu Gao
    Yiu-Cho Chung
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [22] MULTISLICE INVERSION-RECOVERY T1 DETERMINATION USING OPTIMIZED PULSES
    ROBERTS, TPL
    CARPENTER, TA
    HALL, LD
    JOURNAL OF MAGNETIC RESONANCE, 1991, 94 (01): : 160 - 164
  • [23] A PULSE SEQUENCE FOR T1 MEASUREMENT BY INVERSION RECOVERY IN THE PRESENCE OF ACOUSTIC RINGING
    BAGNO, A
    MAGNETIC RESONANCE IN CHEMISTRY, 1992, 30 (12) : 1164 - 1168
  • [24] 2-STAGE INVERSION-RECOVERY EXPERIMENTS FOR MEASUREMENTS OF T1
    TAITELBAUM, H
    FERRETTI, JA
    SPENCER, RGS
    WEISS, GH
    JOURNAL OF MAGNETIC RESONANCE SERIES A, 1993, 105 (01) : 59 - 64
  • [25] Susceptibiliy weighted imaging (SWI) enhanced phase sensitive inversion recovery T1 weighted imaging of the nucleus basalis of Meynert at 7T
    Jethwa, K.
    Aphiwatthanasumet, K.
    Ali, M.
    Mougin, O.
    Gowland, P.
    Auer, D.
    EUROPEAN NEUROPSYCHOPHARMACOLOGY, 2019, 29 : S313 - S313
  • [26] Myocardial T1 mapping at 3.0T using inversion recovery FLASH readout
    Jiaxin Shao
    Kim-Lien Nguyen
    Peng Hu
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [27] EXPERIMENTAL-ANALYSIS OF T1 IMAGING WITH A SINGLE-SCAN, MULTIPLE-POINT, INVERSION RECOVERY TECHNIQUE
    ZHANG, YT
    YEUNG, HN
    CARSON, PL
    ELLIS, JH
    MAGNETIC RESONANCE IN MEDICINE, 1992, 25 (02) : 337 - 343
  • [28] Myocardial Late Gadolinium Enhancement: Accuracy of T1 Mapping-based Synthetic Inversion-Recovery Imaging
    Varga-Szemes, Akos
    van der Geest, Rob J.
    Spottiswoode, Bruce S.
    Suranyi, Pal
    Ruzsics, Balazs
    De Cecco, Carlo N.
    Muscogiuri, Giuseppe
    Cannao, Paola M.
    Fox, Mary A.
    Wichmann, Julian L.
    Vliegenthart, Rozemarijn
    Schoepf, U. Joseph
    RADIOLOGY, 2016, 278 (02) : 374 - 382
  • [29] HIGH-SPEED MULTISLICE T1 MAPPING USING INVERSION-RECOVERY ECHO-PLANAR IMAGING
    ORDIDGE, RJ
    GIBBS, P
    CHAPMAN, B
    STEHLING, MK
    MANSFIELD, P
    MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (02) : 238 - 245
  • [30] T1 inversion recovery pulse sequence: could it replace T1 spin echo sequence in neuroimaging by improving tissue contrast?
    Shawky, Mohamed
    Habib, Rehab
    Elsawaf, Ahmed
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2019, 50 (01):