Compatibility of mechanical and computerized axiographs: A pilot study

被引:10
|
作者
Kucukkeles, N
Ozkan, H
Ari-Demirkaya, A
Cilingiturk, AM
机构
[1] Marmara Univ, Fac Dent, Dept Orthodont, TR-34365 Istanbul, Turkey
[2] Marmara Univ, Fac Business & Adm, Dept Econometr, TR-34365 Istanbul, Turkey
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2005年 / 94卷 / 02期
关键词
D O I
10.1016/j.prosdent.2005.04.025
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. There is little known information comparing axiographic data obtained with a mechanical device and data obtained with a computerized device. However, long-term follow-up of patients may necessitate comparison of previously made mechanical axiographic data with records obtained through computer-aided axiography. Purpose. The purpose of this study was to compare measurements between mechanical and Computerized axiographs in recording the rotational and translation movements of the mandible. Material and methods. The study enrolled 31 subjects with no detectable clinical signs of ternporomandibular disorders. A single operator obtained 3 separate axiographic tracings of right and left condylar paths for each subject, using repeated opening, closing, protrusive, and retrusive movements. Data were collected for both the mechanical (SAM Axiograph Axo 200), and the computerized axiographs (SAM Axiotron and Axo 500). Angular (degrees) and linear measurements (turn) for the mechanical axiograph were made from the tracings obtained on grid paper using a compass, ruler, and protractor. The computer performed the measurements for the computerized axiograph tracings. All parameters were compared statistically with a Wilcoxon signed rank test (alpha=.05). The same operator remeasured all mechanical axiographic tracings for 20 subjects 1 week later to evaluate measurement error. Chronbach's alpha was used as a measure of consistency between the 2 measurements. Results. Mean opening and closing angles varied between 52.4 and 54.2 degrees, and mean protrusive, and retrusive angles varied between 50.1 and 54.9 degrees. Mean opening and closing distances varied between 11.4 and 12.3 mm, and mean protrusive and retrusive distances varied between 8.2 and 8.7 mm. Comparison with the Wilcoxon signed rank test showed no significant differences for any parameter tested. There were high and medium inter-item correlations between repeated measurements of the manual device when Chronbach's alpha was applied, but these results were not sufficient to prove consistency between 2 consecutive measurements. Conclusion. The results showed nonsignificant differences between the recordings of the mechanical and computerized axiographs tested. The authors hypothesize that minor differences may be attributed to hand-measuring errors for the tracings generated by the mechanical axiograph. This study is limited due to the impact of poor precision of the manual device on the study results when these recordings are compared to another instrument. Therefore, it is not possible to conclude that data from the manual and the computerized axiographs arc compatible with each other.
引用
收藏
页码:190 / 194
页数:5
相关论文
共 50 条
  • [41] Validation of computerized tools developed to collect data on safety driving: A pilot study
    Vera Uribe, Ernesto M.
    Armenta, Josue S.
    Baez Perez, Diobar Abraham
    Rodriguez, Marcela D.
    2023 MEXICAN INTERNATIONAL CONFERENCE ON COMPUTER SCIENCE, ENC, 2024,
  • [42] A Pilot Study of the Neuropsychological Benefits of Computerized Cognitive Rehabilitation in Ugandan Children With HIV
    Boivin, Michael J.
    Busman, Rachelle A.
    Parikh, Sujal M.
    Bangirana, Paul
    Page, Connie F.
    Opoka, Robert O.
    Giordani, Bruno
    NEUROPSYCHOLOGY, 2010, 24 (05) : 667 - 673
  • [43] Computerized stress management training for HIV+ women: a pilot intervention study
    Brown, Jennifer L.
    Vanable, Peter A.
    Carey, Michael P.
    Elin, Larry
    AIDS CARE-PSYCHOLOGICAL AND SOCIO-MEDICAL ASPECTS OF AIDS/HIV, 2011, 23 (12): : 1525 - 1532
  • [44] Digital implant impressions by cone-beam computerized tomography: a pilot study
    Corominas-Delgado, Cristina
    Espona, Jose
    Lorente-Gascon, Marian
    Real-Voltas, Francisco
    Roig, Miguel
    Costa-Palau, Santiago
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (11) : 1407 - 1413
  • [45] COMPUTERIZED INTERPRETATION OF THE LURIA-NEBRASKA NEUROPSYCHOLOGICAL BATTERY - A PILOT-STUDY
    HORTON, AM
    VAETH, J
    ANILANE, J
    PERCEPTUAL AND MOTOR SKILLS, 1990, 71 (01) : 83 - 86
  • [46] A Computerized Adaptive Knowledge Test as an assessment tool in general practice: a pilot study
    Roex, A
    Degryse, J
    MEDICAL TEACHER, 2004, 26 (02) : 178 - 183
  • [47] Manual and computerized measurement of coronal vertebral inclination on MRI images: A pilot study
    Vrtovec, T.
    Likar, B.
    Pernus, F.
    CLINICAL RADIOLOGY, 2013, 68 (08) : 807 - 814
  • [48] PILOT-AIRCRAFT COMPATIBILITY IN LANDING APPROACH
    LOOMIS, JP
    BATTELLE TECHNICAL REVIEW, 1967, 16 (02): : 9 - &
  • [49] Rivaroxaban in patients with mechanical heart valves: A pilot study
    Roost, Eva
    Weber, Alberto
    Alberio, Lorenzo
    Englberger, Lars
    Reineke, David
    Keller, Dorothee
    Nagler, Michael
    Carrel, Thierry
    THROMBOSIS RESEARCH, 2020, 186 : 1 - 6
  • [50] BIODEGRADABLE MECHANICAL RETINAL FIXATION - A PILOT-STUDY
    OLSEN, KR
    PAREL, JM
    LEE, W
    HERNANDEZ, E
    FLIESLER, SJ
    ARCHIVES OF OPHTHALMOLOGY, 1989, 107 (05) : 735 - 741