Compatibility of mechanical and computerized axiographs: A pilot study

被引:10
|
作者
Kucukkeles, N
Ozkan, H
Ari-Demirkaya, A
Cilingiturk, AM
机构
[1] Marmara Univ, Fac Dent, Dept Orthodont, TR-34365 Istanbul, Turkey
[2] Marmara Univ, Fac Business & Adm, Dept Econometr, TR-34365 Istanbul, Turkey
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2005年 / 94卷 / 02期
关键词
D O I
10.1016/j.prosdent.2005.04.025
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. There is little known information comparing axiographic data obtained with a mechanical device and data obtained with a computerized device. However, long-term follow-up of patients may necessitate comparison of previously made mechanical axiographic data with records obtained through computer-aided axiography. Purpose. The purpose of this study was to compare measurements between mechanical and Computerized axiographs in recording the rotational and translation movements of the mandible. Material and methods. The study enrolled 31 subjects with no detectable clinical signs of ternporomandibular disorders. A single operator obtained 3 separate axiographic tracings of right and left condylar paths for each subject, using repeated opening, closing, protrusive, and retrusive movements. Data were collected for both the mechanical (SAM Axiograph Axo 200), and the computerized axiographs (SAM Axiotron and Axo 500). Angular (degrees) and linear measurements (turn) for the mechanical axiograph were made from the tracings obtained on grid paper using a compass, ruler, and protractor. The computer performed the measurements for the computerized axiograph tracings. All parameters were compared statistically with a Wilcoxon signed rank test (alpha=.05). The same operator remeasured all mechanical axiographic tracings for 20 subjects 1 week later to evaluate measurement error. Chronbach's alpha was used as a measure of consistency between the 2 measurements. Results. Mean opening and closing angles varied between 52.4 and 54.2 degrees, and mean protrusive, and retrusive angles varied between 50.1 and 54.9 degrees. Mean opening and closing distances varied between 11.4 and 12.3 mm, and mean protrusive and retrusive distances varied between 8.2 and 8.7 mm. Comparison with the Wilcoxon signed rank test showed no significant differences for any parameter tested. There were high and medium inter-item correlations between repeated measurements of the manual device when Chronbach's alpha was applied, but these results were not sufficient to prove consistency between 2 consecutive measurements. Conclusion. The results showed nonsignificant differences between the recordings of the mechanical and computerized axiographs tested. The authors hypothesize that minor differences may be attributed to hand-measuring errors for the tracings generated by the mechanical axiograph. This study is limited due to the impact of poor precision of the manual device on the study results when these recordings are compared to another instrument. Therefore, it is not possible to conclude that data from the manual and the computerized axiographs arc compatible with each other.
引用
收藏
页码:190 / 194
页数:5
相关论文
共 50 条
  • [21] Computerized cognitive testing in patients with Fabry disease: A descriptive pilot study
    Elstein, Deborah
    Doniger, Glen
    Simon, Ely
    Altarescu, Gheona
    MOLECULAR GENETICS AND METABOLISM, 2010, 99 (02) : S17 - S18
  • [22] A pilot study of the Self-Administered Computerized Olfactory Testing System
    Jiang, Rong-San
    Liang, Kai-Li
    AMERICAN JOURNAL OF RHINOLOGY & ALLERGY, 2015, 29 (02) : E55 - E58
  • [23] Computerized Diagnostic Assistant for the Automatic Detection of Pneumothorax on Ultrasound: A Pilot Study
    Summers, Shane M.
    Chin, Eric J.
    Long, Brit J.
    Grisell, Ronald D.
    Knight, John G.
    Grathwohl, Kurt W.
    Ritter, John L.
    Morgan, Jeffrey D.
    Salinas, Jose
    Blackbourne, Lorne H.
    WESTERN JOURNAL OF EMERGENCY MEDICINE, 2016, 17 (04) : 209 - 215
  • [24] Validation of a computerized cognitive assessment system for persons with stroke: a pilot study
    Yip, Chi Kwong
    Man, David W. K.
    INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 2009, 32 (03) : 270 - 278
  • [25] Computerized Automatic Diagnosis of Innocent and Pathologic Murmurs in Pediatrics: A Pilot Study
    Lai, Lillian S. W.
    Redington, Andrew N.
    Reinisch, Andreas J.
    Unterberger, Michael J.
    Schriefl, Andreas J.
    CONGENITAL HEART DISEASE, 2016, 11 (05) : 386 - 395
  • [26] Effectiveness of computerized oculomotor vision screening in a military population: Pilot study
    Capo-Aponte, Jose E.
    Tarbett, Aaron K.
    Urosevich, Thomas G.
    Temme, Leonard A.
    Sanghera, Navjit K.
    Kalich, Melvyn E.
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2012, 49 (09): : 1377 - 1398
  • [27] COMPUTERIZED ELECTROMAGNETIC COMPATIBILITY SPECIFICATION DEVELOPMENT FOR SPACE VEHICLES
    JOHNSON, WR
    IEEE ELECTROMAGNETIC COMPATIBILITY SYMPOSIUM RECORD, 1968, (10): : 246 - &
  • [28] The compatibility of computed tomography scanning and partial REBOA: A large animal pilot study
    Madurska, Marta J.
    Jansen, Jan O.
    Reva, Viktor A.
    Mirghani, Mohammed
    Morrison, Jonathan J.
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2017, 83 (03): : 557 - 561
  • [29] A pilot study of English selectional preferences and their cross-lingual compatibility with Basque
    Agirre, E
    Aldezabal, I
    Pociello, E
    TEXT, SPEECH AND DIALOGUE, PROCEEDINGS, 2003, 2807 : 12 - 19
  • [30] Building envelope and mechanical compatibility
    Khoraskani, R. Afghani
    SpringerBriefs in Applied Sciences and Technology, 2015, 27 : 21 - 32