Effect of TLD-700H (LiF: Mg, Cu, P) sensitivity loss at multiple read-irradiation cycles on TLD reader calibration

被引:9
|
作者
Voss, Shannon P. [1 ]
Sucheta, Artur [1 ]
Romanyukha, Alex [1 ]
Moscovitch, Marco [1 ]
Kennemur, Lisa K. [1 ]
Benevides, Luis A. [1 ]
机构
[1] USN, Dosimetry Ctr, Dept Navy, Bethesda, MD 20889 USA
关键词
Radiation; Dosimetry; Thermo luminescence; LiF:; Mg; Cu; P;
D O I
10.1016/j.radmeas.2011.04.017
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
We investigated the loss of sensitivity on Thermoluminescent Dosimeter (TLD)-700H(LiF: Mg, Cu, P) by Thermo Fisher Scientific at multiple read-irradiation cycles on two different TLD readers. Our test results suggest that the current Time Temperature Profile (UP) with a maximum temperature of 260 degrees C overheats DT-702/PD's thinnest chip 3 causing 29% +/- 7.4% loss in sensitivity over 1000 cycles. For the other three elements, it is significantly less. A possible cause of this effect is overheating of element 3. Our results indicate that one possible solution is to modify TTP for all chips and decouple the UP for chip 3. There is also significant variability ranging from 22% to 40% between different TLD's and 8%-22% for different readers. Calibration cards undergo the highest number of heats and irradiation cycles because they are used to calibrate TLD's and readers. The stability of calibration card's sensitivity is critical to provide accurate dose of record. Any change in the calibration card element correction coefficient (ecc) is reflected immediately in calibration of other TLD's and readers. A variety of processes have been implemented to control sensitivity of calibration cards. Proficiency and intercomparison results support the current operating policy and procedures to protect the accuracy and efficiency of our personnel dose program. Suggested TIP modification may reduce the loss of sensitivity for and may extend the life of calibration TLD's to over 1000 heat cycles. Published by Elsevier Ltd.
引用
收藏
页码:1590 / 1594
页数:5
相关论文
共 10 条
  • [1] Effect of neutron irradiation on dosimetric properties of TLD-600H (6LiF:Mg,Cu,P)
    Romanyukha, A.
    Minniti, R.
    Moscovitch, M.
    Thompson, A. K.
    Trompier, F.
    Colle, R.
    Sucheta, A.
    Voss, S. P.
    Benevides, L. A.
    RADIATION MEASUREMENTS, 2011, 46 (12) : 1426 - 1431
  • [2] A comparative study on the susceptibility of LiF:Mg,Ti (TLD-100) and LiF:Mg,Cu,P (TLD-100H) to spurious signals in thermoluminescence dosimetry
    Al-Haj, Abdalla
    Lagarde, Charlie
    Mahyoub, Fareed
    RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 399 - 402
  • [3] Anomalous behavior of LiF:Mg,Cu,P (TLD100H) irradiated with electron beams
    Triolo, A.
    Brai, M.
    Bartolotta, A.
    Marrale, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 568 (02): : 784 - 791
  • [4] Further studies in the reduction of residual in Harshaw TLD-100H (LiF:Mg,Cu,P)
    Ramlo, M.
    Moscovitch, M.
    Rotunda, J. E.
    RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 217 - 219
  • [5] LET-calibration of a new TLD-system LiF:Mg, Ti/LiF:Mg,Cu,P for let-determination in mixed radiation fields
    Torkzadeh, F
    Vana, N
    Noll, M
    Fugger, M
    RADIOACTIVITY IN HUMANS AND THE ENVIRONMENT, 1998, : 695 - 700
  • [7] Effect of ion bombardment on the Tl-response of both LiF (TLD-100) and a home-made LiF:Mg,Cu,P phosphors
    AbdelHamid, HM
    Hussein, MA
    AbouZeid, HM
    Morsy, SM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 132 (01): : 119 - 122
  • [8] Sensitivity loss and recovery for individual TL peaks in LiF:Mg,Ti and LiF:Mg,Cu,P after high-dose irradiation
    Bilski, P.
    Cybulski, T.
    Puchalska, M.
    Ptaszkiewicz, M.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 357 - 360
  • [9] TYPE TESTING OF LiF:Mg,Cu,P (TLD-100H) WHOLE-BODY DOSEMETERS FOR THE ASSESSMENT OF Hp(10) AND Hp(0.07)
    Pereira, J. S.
    Pereira, M. F.
    Rangel, S.
    Caldeira, M.
    Carvalhal, G.
    Santos, L. M.
    Cardoso, J. V.
    Alves, J. G.
    RADIATION PROTECTION DOSIMETRY, 2019, 184 (02) : 216 - 223
  • [10] Effect of short-term sensitivity loss in LiF:Mg,Cu,P thermoluminescent dosemeter and its implications on personnel dosimetry operations
    Romanyukha, Alexander
    Delzer, Jeffrey A.
    Grypp, Matthew D.
    Williams, Anthony S.
    RADIATION PROTECTION DOSIMETRY, 2016, 168 (02) : 204 - 211