Determination of acibenzolar-S-methyl and its acidic metabolite in soils by HPLC-diode array detection

被引:8
|
作者
Myresiotis, Charalampos K. [1 ]
Papadakis, Emmanouil N.
Vryzas, Zisis G. [2 ]
Papadopoulou-Mourkidou, Euphemia
机构
[1] Aristotle Univ Thessaloniki, Pesticide Sci Lab, Fac Agr, Thessaloniki 54124, Greece
[2] Democritus Univ Thrace, Lab Agr Pharmacol & Ecotoxicol, Orestias, Greece
关键词
acibenzolar-S-methyl; systemic acquired resistance (SAR); plant activator; soil; pesticides; HPLC-UV; extraction; SYSTEMIC ACQUIRED-RESISTANCE; BACTERIAL SPOT; EXTRACTION; INDUCTION; PRODUCTS; TOMATO; PLANTS;
D O I
10.1080/03601234.2011.583881
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A simple and accurate method for the analysis of acibenzolar-S-methyl (benzo[1,2,3] thiadiazole-7-carbothioic acid-S-methyl ester; CGA 245 704; ASM) and its major conversion product, benzo[1,2,3] thiadiazole-7-carboxylic acid (CGA 210 007; BTC), in soils is presented. ASM extraction from soil samples was performed using acetonitrile and BTC was extracted with a mixture of potassium phosphate buffer (0.5 M, pH 3) and acetonitrile (70: 30 %, v/v). Both extracts were directly analyzed in a high-performance liquid chromatography-diode array detection (HPLC-DAD) system. Pesticide separation was achieved on a C18 (4.6 mm x 150 mm, 5 mu m) analytical column with a isocratic elution of acetonitrile: water 40:60 % (v/v) with 0.6 mL L-1 acetic acid at a flow rate of 1 mL min(-1). Linear regression coefficients (r(2)) of the external calibration curves were always above 0.9997. The limits of detection (LOD) and quantification (LOQ) of the method were 0.005 and 0.02 mg Kg(-1) for ASM, and 0.01 and 0.05 mg Kg(-1) for BTC, respectively. Recoveries were investigated at six fortification levels and were in the range of 90-120 % for ASM and 74-96 % for BTC with relative standard deviations (RSDs) below 11% in all cases. The method was also validated by analyzing freshly spiked soil samples with 2.7% organic matter content at 0.5 mg Kg(-1) level, with slightly lower recovery values only for ASM. Moreover, recoveries for intermediate aged residues of the analytes were similar to fresh residues. This method was also applied to determine ASM half-life (t(1/2) = 8.7 h) and the rate of the acidic metabolite formation.
引用
收藏
页码:550 / 556
页数:7
相关论文
共 50 条
  • [31] Ellman’s method-based determination of acibenzolar-S-methyl in tobacco by transesterification with methanol and SABP2-catalyzed hydrolysis
    Kang Yang
    Wenyu Sun
    Qiang Li
    Jingfeng Wang
    Jianzhuang Yao
    Xia Wang
    Analytical Sciences, 2022, 38 : 749 - 757
  • [32] Ellman's method-based determination of acibenzolar-S-methyl in tobacco by transesterification with methanol and SABP2-catalyzed hydrolysis
    Yang, Kang
    Sun, Wenyu
    Li, Qiang
    Wang, Jingfeng
    Yao, Jianzhuang
    Wang, Xia
    ANALYTICAL SCIENCES, 2022, 38 (05) : 749 - 757
  • [33] DETERMINATION OF NITROGEN-CONTAINING PESTICIDES BY HPLC WITH DIODE-ARRAY DETECTION
    REUPERT, R
    PLOGER, E
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 331 (05): : 503 - 509
  • [34] Enantioseparation and determination of asenapine in biological fluid micromatrices by HPLC with diode array detection
    Protti, Michele
    Vignali, Alice
    Blanco, Teresa Sanchez
    Rudge, James
    Bugamelli, Francesca
    Ferranti, Anna
    Mandrioli, Roberto
    Mercolini, Laura
    JOURNAL OF SEPARATION SCIENCE, 2018, 41 (06) : 1257 - 1265
  • [35] DETERMINATION OF AMINO-ACID HYDANTOINS BY HPLC WITH DIODE-ARRAY DETECTION
    HUANG, ZX
    OUGH, CS
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1991, 39 (12) : 2218 - 2222
  • [36] The determination and distribution of nucleotides in dairy products using HPLC and diode array detection
    Ferreira, IMPLVO
    Mendes, E
    Gomes, AMP
    Faria, MA
    Ferreira, MA
    FOOD CHEMISTRY, 2001, 74 (02) : 239 - 244
  • [37] Determination of benzodiazepines in forensic samples by HPLC with photo-diode array detection
    He, WD
    Parissis, N
    Kiratzidis, T
    JOURNAL OF FORENSIC SCIENCES, 1998, 43 (05) : 1061 - 1067
  • [38] Hplc determination of vasicine and vasicinone in Adhatoda vasica with photo diode array detection
    Srivastava, S
    Verma, RK
    Gupta, MM
    Singh, SC
    Kumar, S
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2001, 24 (02) : 153 - 159
  • [39] Development and full validation of an innovative HPLC-diode array detection technique to simultaneously quantify lacosamide, levetiracetam and zonisamide in human plasma
    Goncalves, Joana
    Alves, Gilberto
    Bicker, Joana
    Falcao, Amilcar
    Fortuna, Ana
    BIOANALYSIS, 2018, 10 (08) : 541 - 557
  • [40] Analysis of sennosides A and B from dieter's tea by HPLC-diode array spectrophotometry and negative ion electrospray mass spectrometry
    Liao, W
    Chiu, K
    Mabuni, C
    Soliman, M
    BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1998, 61 (03) : 317 - 324