Determination of acibenzolar-S-methyl and its acidic metabolite in soils by HPLC-diode array detection

被引:8
|
作者
Myresiotis, Charalampos K. [1 ]
Papadakis, Emmanouil N.
Vryzas, Zisis G. [2 ]
Papadopoulou-Mourkidou, Euphemia
机构
[1] Aristotle Univ Thessaloniki, Pesticide Sci Lab, Fac Agr, Thessaloniki 54124, Greece
[2] Democritus Univ Thrace, Lab Agr Pharmacol & Ecotoxicol, Orestias, Greece
关键词
acibenzolar-S-methyl; systemic acquired resistance (SAR); plant activator; soil; pesticides; HPLC-UV; extraction; SYSTEMIC ACQUIRED-RESISTANCE; BACTERIAL SPOT; EXTRACTION; INDUCTION; PRODUCTS; TOMATO; PLANTS;
D O I
10.1080/03601234.2011.583881
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A simple and accurate method for the analysis of acibenzolar-S-methyl (benzo[1,2,3] thiadiazole-7-carbothioic acid-S-methyl ester; CGA 245 704; ASM) and its major conversion product, benzo[1,2,3] thiadiazole-7-carboxylic acid (CGA 210 007; BTC), in soils is presented. ASM extraction from soil samples was performed using acetonitrile and BTC was extracted with a mixture of potassium phosphate buffer (0.5 M, pH 3) and acetonitrile (70: 30 %, v/v). Both extracts were directly analyzed in a high-performance liquid chromatography-diode array detection (HPLC-DAD) system. Pesticide separation was achieved on a C18 (4.6 mm x 150 mm, 5 mu m) analytical column with a isocratic elution of acetonitrile: water 40:60 % (v/v) with 0.6 mL L-1 acetic acid at a flow rate of 1 mL min(-1). Linear regression coefficients (r(2)) of the external calibration curves were always above 0.9997. The limits of detection (LOD) and quantification (LOQ) of the method were 0.005 and 0.02 mg Kg(-1) for ASM, and 0.01 and 0.05 mg Kg(-1) for BTC, respectively. Recoveries were investigated at six fortification levels and were in the range of 90-120 % for ASM and 74-96 % for BTC with relative standard deviations (RSDs) below 11% in all cases. The method was also validated by analyzing freshly spiked soil samples with 2.7% organic matter content at 0.5 mg Kg(-1) level, with slightly lower recovery values only for ASM. Moreover, recoveries for intermediate aged residues of the analytes were similar to fresh residues. This method was also applied to determine ASM half-life (t(1/2) = 8.7 h) and the rate of the acidic metabolite formation.
引用
收藏
页码:550 / 556
页数:7
相关论文
共 50 条
  • [21] HPLC with diode-array detection for determination of leflunomide in tablets
    Miron, DS
    Soldattelli, C
    Schapoval, EES
    CHROMATOGRAPHIA, 2006, 63 (5-6) : 283 - 287
  • [22] HPLC with Diode-Array Detection for Determination of Leflunomide in Tablets
    D. S. Miron
    C. Soldattelli
    E. E. S. Schapoval
    Chromatographia, 2006, 63 : 283 - 287
  • [23] DETERMINATION OF RETINYL PALMITATE IN OINTMENT BY HPLC WITH DIODE ARRAY DETECTION
    Kwiecien, Anna
    Hubicka, Urszula
    Krzek, Jan
    ACTA POLONIAE PHARMACEUTICA, 2010, 67 (05): : 475 - 479
  • [24] Detection of DNA-bound advanced glycation end-products by immunoaffinity chromatography coupled to HPLC-diode array detection
    Schneider, M
    Georgescu, A
    Bidmon, C
    Tutsch, M
    Fleischmann, EH
    Popov, D
    Pischetsrieder, M
    MOLECULAR NUTRITION & FOOD RESEARCH, 2006, 50 (4-5) : 424 - 429
  • [25] Determination of analytes in medical herbs extracts by SPE coupled with two-dimensional planar chromatography in combination with diode array scanning densitometry and HPLC-diode array detector
    Tuzimski, Tomasz
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (01) : 27 - 36
  • [26] Determination and confirmation of isopropyl p-toluenesulfonate in cosmetics by HPLC-diode array detector method and GC-MS
    Tay, B. Y. P.
    Yung, S. C.
    Teoh, T. Y.
    INTERNATIONAL JOURNAL OF COSMETIC SCIENCE, 2016, 38 (06) : 627 - 633
  • [27] Determination of Gatifloxacin in Semen by HPLC with Diode-Array and Fluorescence Detection
    M. L. Salazar Cavazos
    L. Y. Colunga González
    G. Gallegos de Lerma
    N. Waksman de Torres
    Chromatographia, 2006, 63 : 605 - 608
  • [28] Determination of gatifloxacin in semen by HPLC with diode-array and fluorescence detection
    Salazar-Cavazos, M. L.
    Gonzalez, L. Y. Colunga
    de Lerma, G. Gallegos
    de Torres, N. Waksman
    CHROMATOGRAPHIA, 2006, 63 (11-12) : 605 - 608
  • [29] Analysis of antioxidant compounds in sweet orange peel by HPLC-diode array detection-electrospray ionization mass spectrometry
    Anagnostopoulou, MA
    Kefalas, P
    Kokkalou, E
    Assimopoulou, AN
    Papageorgiou, VP
    BIOMEDICAL CHROMATOGRAPHY, 2005, 19 (02) : 138 - 148
  • [30] A Validated HPLC-Diode Array Detection Method for Therapeutic Drug Monitoring of Thiopurines in Pediatric Patients: From Bench to Bedside
    Franzin, Martina
    Curci, Debora
    Lucafo, Marianna
    Bramuzzo, Matteo
    Rabusin, Marco
    Fabretto, Antonella
    Addobbati, Riccardo
    Stocco, Gabriele
    Decorti, Giuliana
    METABOLITES, 2022, 12 (12)