Comparison of four methods for the estimation of intracranial volume: A gold standard study

被引:53
|
作者
Sahin, B. [1 ]
Acer, N.
Sonmez, O. F.
Emirzeoglu, M.
Basaloglu, H.
Uzun, A.
Bilgic, S.
机构
[1] Ondokuz Mayis Univ, Sch Med, Dept Anat, TR-55139 Samsun, Turkey
[2] Univ Mugla, Allied Hlth Sch, Dept Nursing, Mugla, Turkey
[3] Gazi Govt Hosp, Neurosurg Clin, Samsun, Turkey
[4] Adnan Menderes Univ, Sch Med, Dept Anat, Aydin, Turkey
关键词
intracranial volume; water-filling; cephalometry; point-counting; planimetry; stereology;
D O I
10.1002/ca.20520
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
Investigators can infer how much reduction in volume has occurred since brain volume was at its peak, by combining measures of brain volume with measures of intracranial volume (ICV). Several methodologies have been proposed to asses the ICV. However, we have not seen a gold-standard study evaluating the results of the methodologies for the assessment of ICV. In the present study, the actual intracranial volume of 20 dry skulls was measured using the water-filling method, using this as a gold standard. Anthropometry, cephalometry, point-counting, and planimetry techniques were applied to the same skulls to estimate the ICV. Anthropometric and cephalometric measurements were carried out directly on skulls and roentgenograms, respectively. Consecutive computed tomography sections at a thickness of 10 mm were used to estimate the ICV of the skulls by means of the point-counting and planimetry methods. The mean (+/- SD) of the actual ICV measured by the water-filling method was 1,262.0 +/- 160.4 cm(3) (1,389.5 +/- 96.5 cm(3) for males and 1,134.5 +/- 94.3 cm 3 for females, respectively). Our results showed that the estimated values obtained by all four methods differed from the actual volumes of the skulls (P < 0.05). The data obtained by anthropometry resulted in overestimation. However, cephalometry, point-counting, and planimetry methods produced underestimation. After calibration, there were no significant differences between the actual volumes and the results of the four methods (P > 0.05). While the anthropometric method is easy and quick to apply, its result may deviate from the actual values. The optimized stereological techniques of point-counting and planimetry methods may provide unbiased ICV results since they take the third dimension of the structures into account.
引用
收藏
页码:766 / 773
页数:8
相关论文
共 50 条
  • [1] Estimation of polyvinyl alcohol cryogel mechanical properties with four ultrasound elastography methods and comparison with gold standard testings
    Fromageau, Jeremie
    Gennisson, Jean-Luc
    Schmitt, Cedric
    Maurice, Roch L.
    Mongrain, Rosaire
    Cloutier, Guy
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2007, 54 (03) : 498 - 509
  • [2] Comparison of three methods for the estimation of total intracranial volume - Stereologic, planimetric, and anthropometric approaches
    Acer, Niyazi
    Sahin, Bunyamin
    Bas, Orhan
    Ertekin, Tolga
    Usanmaz, Mustafa
    ANNALS OF PLASTIC SURGERY, 2007, 58 (01) : 48 - 53
  • [3] A comparison of intracranial volume estimation methods and their cross-sectional and longitudinal associations with age
    Nerland, Stener
    Stokkan, Therese S.
    Jorgensen, Kjetil N.
    Wortinger, Laura A.
    Richard, Genevieve
    Beck, Dani
    van Der Meer, Dennis
    Westlye, Lars T.
    Andreassen, Ole A.
    Agartz, Ingrid
    Barth, Claudia
    HUMAN BRAIN MAPPING, 2022, 43 (15) : 4620 - 4639
  • [4] Comparison of Measurement Methods for Stone Volume Estimation: An In Vitro Study
    Pauchard, Felipe
    Panthier, Frederic
    Espinoza, Catalina
    Vejar, Nataly
    Ventimiglia, Eugenio
    Traxer, Olivier
    JOURNAL OF ENDOUROLOGY, 2025,
  • [5] A comparison of four methods of herbage mass estimation
    O'Donovan, M
    Dillon, P
    Rath, M
    Stakelum, G
    IRISH JOURNAL OF AGRICULTURAL AND FOOD RESEARCH, 2002, 41 (01) : 17 - 27
  • [6] ESTIMATION OF GLOMERULAR VOLUME - A COMPARISON OF 4 METHODS
    LANE, PH
    STEFFES, MW
    MAUER, SM
    KIDNEY INTERNATIONAL, 1992, 41 (04) : 1085 - 1089
  • [7] Practical methods for segmentation and calculation of brain volume and intracranial volume: a guide and comparison
    Harkey, Thomas
    Baker, David
    Hagen, John
    Scott, Hayden
    Palys, Viktoras
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (07) : 3748 - +
  • [8] Comparison of three unconjugated estriol methods to the gold standard method
    Scheibe, B. R.
    Bornhorst, J. A.
    Blacklaw, M. K.
    Wiley, C. L.
    CLINICAL CHEMISTRY, 2008, 54 (06) : A230 - A230
  • [9] Refining the gold standard: Volume calibration methods for right ventricular pressure-volume loops
    Houston, Brian A.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2025, 44 (03): : 336 - 338
  • [10] Comparison of methods for curvature estimation from volume fractions
    Han, Austin
    Evrard, Fabien
    Desjardins, Olivier
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2024, 174