Dual-Energy CT Iodine Mapping and 40-keV Monoenergetic Applications in the Diagnosis of Acute Bowel Ischemia

被引:67
|
作者
Lourenco, Pedro D. M. [1 ]
Rawski, Ryan [2 ]
Mohammed, Mohammed F. [1 ,3 ]
Khosa, Faisal [1 ]
Nicolaou, Savvas [1 ]
McLaughlin, Patrick [1 ]
机构
[1] Univ British Columbia, Vancouver Gen Hosp, Dept Radiol, 3350-950 W 10th Ave, Vancouver, BC V5Z 1M9, Canada
[2] Univ Calgary, Dept Radiol, Calgary, AB, Canada
[3] King Saud bin Abdulaziz Univ Hlth Sci, Abdominal Imaging Sect, Med Imaging Dept, King Abdullah Int Med Res Ctr,Minist Natl Guard,H, Riyadh, Saudi Arabia
关键词
acute intestinal ischemia; bowel ischemia; dual-energy CT; iodine mapping; virtual monoenergetic; ACUTE MESENTERIC ISCHEMIA; MDCT; MANAGEMENT;
D O I
10.2214/AJR.18.19554
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Sensitivity of CT of the abdomen for detection of acute bowel ischemia (ABI) can be as low as 60%. In this study, we assessed the diagnostic performance of iodinemap and monoenergetic (40-keV) images in patients with suspected ABI. MATERIALS AND METHODS. This retrospective study included 60 consecutive patients with suspected ABI who underwent a standardized imaging protocol dual-source dualenergy CT (DECT) over a 26-month period. Clinical and operative outcomes were recorded as the reference standard. Two abdominal radiologists who were unaware of clinical and surgical information independently assessed conventional CT images for ABI. After a time interval designed to reduce recall, readers reassessed conventional images with supplementary iodine-map and 40-keV postprocessed images. Quantitative ROI analysis was also performed. RESULTS. ABI was observed in 11 patients. For reader A, sensitivity was 63.6% (95% CI, 30.8-89.1%) when interpreting conventional images alone. Sensitivity for detection of ABI increased to 81.8% (95% CI, 48.2-97.7%) and 100% (95% CI, 71.5-100%) when iodine-map and 40-keV images were assessed, respectively. For reader B, no change in sensitivity was seen with either technique, but the number of false-positives were reduced with supplementary iodinemap and 40-keV postprocessed images. Interobserver agreement was fair with conventional images (lc = 0.29) but improved to moderate (x = 0.45) and substantial (x = 0.63) with iodinemap and 40-keV images, respectively. Quantitative assessment found significant differences in iodine uptake (1.01 +/- 0.55 mg/mL vs 3.04 +/- 1.19 mg/mL) and mean attenuation (75.2 +/- 38.4 HU vs 163.5 +/- 48.9 HU) between nonischemic and ischemic segments, respectively. CONCLUSION. Iodine-map and 40-keV monoenergetic images increase conspicuity of ABI, resulting in improved diagnostic accuracy compared with review of conventional CT images alone.
引用
收藏
页码:564 / 570
页数:7
相关论文
共 50 条
  • [1] Dual-Energy CT Iodine Mapping and 40-keV Monoenergetic Applications in the Diagnosis of Acute Bowel Ischemia: A Necessary Clarification
    Mazzei, Maria Antonietta
    Gentili, Francesco
    Volterrani, Luca
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 212 (03) : W93 - W94
  • [2] Reply to "Dual-Energy CT Iodine Mapping and 40-keV Monoenergetic Applications in the Diagnosis of Acute Bowel Ischemia: A Necessary Clarification"
    Lourenco, Pedro D. M.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 212 (03) : W95 - W95
  • [3] Iodine density mapping for the diagnosis of acute bowel ischemia using fast kV-switching dual-energy CT
    Xu, Jack Junchi
    Ulriksen, Peter Sommer
    Jawad, Samir
    Rohde, Yecatarina Zincuk
    Sejer, Morten
    Achiam, Michael Patrick
    Resch, Timothy Andrew
    Lonn, Lars
    Hansen, Kristoffer Lindskov
    [J]. ABDOMINAL RADIOLOGY, 2024, 49 (01) : 312 - 319
  • [4] Iodine density mapping for the diagnosis of acute bowel ischemia using fast kV-switching dual-energy CT
    Jack Junchi Xu
    Peter Sommer Ulriksen
    Samir Jawad
    Yecatarina Zincuk Rohde
    Morten Sejer
    Michael Patrick Achiam
    Timothy Andrew Resch
    Lars Lönn
    Kristoffer Lindskov Hansen
    [J]. Abdominal Radiology, 2024, 49 : 312 - 319
  • [5] Dual-energy CT of acute bowel ischemia
    Markus M. Obmann
    Gopal Punjabi
    Verena C. Obmann
    Daniel T. Boll
    Tobias Heye
    Matthias R. Benz
    Benjamin M. Yeh
    [J]. Abdominal Radiology, 2022, 47 : 1660 - 1683
  • [6] Dual-energy CT of acute bowel ischemia
    Obmann, Markus M.
    Punjabi, Gopal
    Obmann, Verena C.
    Boll, Daniel T.
    Heye, Tobias
    Benz, Matthias R.
    Yeh, Benjamin M.
    [J]. ABDOMINAL RADIOLOGY, 2022, 47 (05) : 1660 - 1683
  • [7] Low-iodine 40-keV virtual monoenergetic CT angiography of the lower extremities
    Fahrni, Guillaume
    Mingas, Thomas
    Deliessche, Arthur
    Hraichi, Smail
    Rotzinger, David C.
    Si-Mohamed, Salim A.
    Boccalini, Sara
    Douek, Philippe
    [J]. FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [8] Deep learning–based image reconstruction of 40-keV virtual monoenergetic images of dual-energy CT for the assessment of hypoenhancing hepatic metastasis
    Taehee Lee
    Jeong Min Lee
    Jeong Hee Yoon
    Ijin Joo
    Jae Seok Bae
    Jeongin Yoo
    Jae Hyun Kim
    Chulkyun Ahn
    Jong Hyo Kim
    [J]. European Radiology, 2022, 32 : 6407 - 6417
  • [9] Deep learning-based image reconstruction of 40-keV virtual monoenergetic images of dual-energy CT for the assessment of hypoenhancing hepatic metastasis
    Lee, Taehee
    Lee, Jeong Min
    Yoon, Jeong Hee
    Joo, Ijin
    Bae, Jae Seok
    Yoo, Jeongin
    Kim, Jae Hyun
    Ahn, Chulkyun
    Kim, Jong Hyo
    [J]. EUROPEAN RADIOLOGY, 2022, 32 (09) : 6407 - 6417
  • [10] Pancreatic cancer detection with dual-energy CT: diagnostic performance of 40 keV and 70 keV virtual monoenergetic images
    Yoshifumi Noda
    Tomohiro Ando
    Tetsuro Kaga
    Nao Yamda
    Takuya Seko
    Takuma Ishihara
    Nobuyuki Kawai
    Toshiharu Miyoshi
    Akio Ito
    Takuya Naruse
    Fuminori Hyodo
    Hiroki Kato
    Avinash R. Kambadakone
    Masayuki Matsuo
    [J]. La radiologia medica, 2024, 129 : 677 - 686