Synthesis of a magnetic covalent organic framework as sorbents for solid-phase extraction of aflatoxins in food prior to quantification by liquid chromatography-mass spectrometry

被引:29
|
作者
Li, Jie [1 ,2 ]
Xu, Xiuli [1 ]
Guo, Wei [1 ]
Zhang, Yuan [2 ]
Feng, Xuesong [2 ]
Zhang, Feng [1 ]
机构
[1] Chinese Acad Inspect & Quarantine, Inst Food Safety, Beijing 100176, Peoples R China
[2] China Med Univ, Sch Pharm, Shenyang 110122, Liaoning, Peoples R China
关键词
Magnetic covalent organic framework; Magnetic dispersive SPE; Aflatoxins; Food matrices; LC-MS/MS; REMOVAL; ENRICHMENT; MYCOTOXIN; ADSORBENT; SHELL;
D O I
10.1016/j.foodchem.2022.132821
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A novel magnetic dispersive SPE (MDSPE) based on magnetic covalent organic framework (M-COF) coupled with liquid chromatography-mass spectrometry (LC-MS/MS) was developed for the determination of AFB1, AFB2, AFG1 and AFG2 in food matrices (milk, edible oil and rice). The M-COF was designed and constructed by using two novel monomers of 1,2,4,5-Tetrakis-(4-formylphenyl)benzene (TFPB) and p-Phenylenediamine (PPD) at room temperature. Various techniques were used to verify the successful synthesis of the M-COF. The adsorption capacities of M-COF for AFs were in the range of 69.5-92.2 mg/g. Major parameters influencing extraction efficiency were optimized, making MDSPE time-saving (5 min) and organic-reagent-saving (2 mL). The M-COF can reutilize more than 8 times. After being quantified by LC-MS/MS, good linear relationships (determination coefficient of R-2 > 0.9990) were obtained. The LODs were in the range of 0.01-0.05 mu g/kg. The recoveries ranged from 76.4 to 112.5%. Both intra- and inter-day precision were less than 15%.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] The detection of drugs of abuse and pharmaceuticals in drinking water using solid-phase extraction and liquid chromatography-mass spectrometry
    Peng, Yan
    Gautam, Lata
    Hall, Sarah W.
    CHEMOSPHERE, 2019, 223 : 438 - 447
  • [42] Solid-phase extraction followed by liquid chromatography-mass spectrometry for trace determination of β-lactam antibiotics in bovine milk
    Bruno, F
    Curini, R
    Di Corcia, A
    Nazzari, M
    Samperi, R
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2001, 49 (07) : 3463 - 3470
  • [43] Determination of ketobemidone and its metabolites in plasma and urine using solid-phase extraction and liquid chromatography-mass spectrometry
    Svensson, JO
    Säwe, J
    Al-Shurbaji, A
    THERAPEUTIC DRUG MONITORING, 2001, 23 (04) : 399 - 405
  • [44] Determination of benzothiazoles from complex aqueous samples by liquid chromatography-mass spectrometry following solid-phase extraction
    Kloepfer, A
    Jekel, M
    Reemtsma, T
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1058 (1-2) : 81 - 88
  • [45] Determination of pesticides and their degradation products in water samples by solid-phase extraction coupled with liquid chromatography-mass spectrometry
    Wang, Xin
    Jia, Ruibao
    Song, Yan
    Wang, Mingquan
    Zhao, Qinghua
    Sun, Shaohua
    MICROCHEMICAL JOURNAL, 2019, 149
  • [46] Application of solid-phase extraction and liquid chromatography-mass spectrometry to the determination of neonicotinoid pesticide residues in fruit and vegetables
    Di Muccio, A
    Fidente, P
    Barbini, DA
    Dommarco, R
    Seccia, S
    Morrica, P
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1108 (01) : 1 - 6
  • [47] Determination of the nucleosides and nucleobases in Tuber samples by dispersive solid-phase extraction combined with liquid chromatography-mass spectrometry
    Liu, Ping
    Li, Yuan-Yuan
    Li, Hong-Mei
    Wan, Duan-Ji
    Tang, Ya-Jie
    ANALYTICA CHIMICA ACTA, 2011, 687 (02) : 159 - 167
  • [48] Method development and validation for the quantification of organic acids in microbial samples using anionic exchange solid-phase extraction and gas chromatography-mass spectrometry
    Heyen, Simone
    Scholz-Boettcher, Barbara M.
    Rabus, Ralf
    Wilkes, Heinz
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (27) : 7491 - 7503
  • [49] Method development and validation for the quantification of organic acids in microbial samples using anionic exchange solid-phase extraction and gas chromatography-mass spectrometry
    Simone Heyen
    Barbara M. Scholz-Böttcher
    Ralf Rabus
    Heinz Wilkes
    Analytical and Bioanalytical Chemistry, 2020, 412 : 7491 - 7503
  • [50] Modified QuEChERS Combination with Magnetic Solid-Phase Extraction for the Determination of 16 Preservatives by Gas Chromatography-Mass Spectrometry
    Chen, Yaling
    Cao, Shurui
    Zhang, Lei
    Xi, Cunxian
    Chen, Zhiqiong
    FOOD ANALYTICAL METHODS, 2017, 10 (03) : 587 - 595