The influence of storage time and temperature on the measurement of serum, plasma and urine osmolality

被引:10
|
作者
Bezuidenhout, Karla [1 ,2 ]
Rensburg, Megan A. [3 ,4 ]
Hudson, Careen L. [4 ]
Essack, Younus [5 ]
Davids, M. Razeen [1 ,2 ]
机构
[1] Univ Stellenbosch, Dept Med, Div Nephrol, ZA-7505 Cape Town, South Africa
[2] Tygerberg Hosp, Cape Town, South Africa
[3] Univ Stellenbosch, Div Chem Pathol, ZA-7505 Cape Town, South Africa
[4] Natl Hlth Lab Serv, Greenpoint Complex, Cape Town, South Africa
[5] PathCare Labs, Cape Town, South Africa
关键词
Analytes; laboratory methods; STABILITY;
D O I
10.1177/0004563215602028
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Many clinical laboratories require that specimens for serum and urine osmolality determination be processed within 3 h of sampling or need to arrive at the laboratory on ice. This protocol is based on the World Health Organization report on sample storage and stability, but the recommendation lacks good supporting data. We studied the effect of storage temperature and time on osmolality measurements. Methods: Blood and urine samples were obtained from 16 patients and 25 healthy volunteers. Baseline serum, plasma and urine osmolality measurements were performed within 30 min. Measurements were then made at 3, 6, 12, 24 and 36 h on samples stored at 4-8 degrees C and room temperature. We compared baseline values with subsequent measurements and used difference plots to illustrate changes in osmolality. Results: At 4-8 degrees C, serum and plasma osmolality were stable for up to 36 h. At room temperature, serum and plasma osmolality were very stable for up to 12 h. At 24 and 36 h, changes from baseline osmolality were statistically significant and exceeded the total allowable error of 1.5% but not the reference change value of 4.1%. Urine osmolality was extremely stable at room temperature with a mean change of less than 1 mosmol/kg at 36 h. Conclusions: Serum and plasma samples can be stored at room temperature for up to 36 h before measuring osmolality. Cooling samples to 4-8 degrees C may be useful when delays in measurement beyond 12 h are anticipated. Urine osmolality is extremely stable for up to 36 h at room temperature.
引用
收藏
页码:452 / 458
页数:7
相关论文
共 50 条
  • [41] INFLUENCE OF SHAM STOMACH LOADING ON SERUM OSMOLALITY
    KAKOLEWSKI, JW
    DEAUX, E
    PHYSIOLOGY & BEHAVIOR, 1970, 5 (10) : 1205 - +
  • [42] MEASUREMENT OF PLATINUM IN SERUM AND URINE BY DC PLASMA EMISSION-SPECTROMETRY
    MCLOUGHLIN, S
    BOWDLER, D
    ROBERTS, NB
    TAYLOR, WH
    CLINICAL SCIENCE, 1986, 71 : P32 - P32
  • [43] THE MEASUREMENT OF HEPARIN AND OTHER THERAPEUTIC SULFATED POLYSACCHARIDES IN PLASMA, SERUM AND URINE
    DAWES, J
    PROWSE, CV
    PEPPER, DS
    THROMBOSIS AND HAEMOSTASIS, 1985, 54 (03) : 630 - 634
  • [44] Stability of serum β-crosslaps during storage:: Influence of pH and storage temperature
    Herrmann, M
    Pape, G
    Herrmann, W
    CLINICAL CHEMISTRY, 2001, 47 (05) : 939 - 940
  • [45] Proteomic analysis for influence of storage temperature on human serum
    Kim, K. S.
    Lee, D. H.
    Kim, J. W.
    Jeon, S. Y.
    Park, S. G.
    Jung, S. E.
    Kim, H. T.
    Kim, S. C.
    Kimm, K.
    Kim, H. L.
    Han, B. G.
    CELL PRESERVATION TECHNOLOGY, 2007, 5 (01): : 61 - 62
  • [46] WATER DRINKING TEST COMBINED WITH MEASUREMENT OF SERUM OSMOLALITY
    CRISTIANSSON, J
    MERTENS, O
    ACTA OPHTHALMOLOGICA, 1969, 47 (01) : 248 - +
  • [47] Transport and temperature effects on measurement of serum and plasma potassium
    Seamark, D
    Backhouse, S
    Barber, P
    Hichens, J
    Salzmann, M
    Powell, R
    JOURNAL OF THE ROYAL SOCIETY OF MEDICINE, 1999, 92 (07) : 339 - 341
  • [48] INFLUENCE OF AGE ON PLASMA OSMOLALITY - A COMMUNITY STUDY
    MCLEAN, KA
    ONEILL, PA
    DAVIES, I
    MORRIS, J
    AGE AND AGEING, 1992, 21 (01) : 56 - 60
  • [49] Urine osmolality assessment through the integration of urea hydrolysis and impedance measurement
    Kong, Tian Fook
    Shen, Xinhui
    Sim, Mei Yi
    Yong, Jin
    Ng, Tze Kiat
    Chong, Tsung Wen
    Marcos
    LAB ON A CHIP, 2024, 24 (15) : 3728 - 3737
  • [50] Variability among four refractometers for the measurement of urine specific gravity and comparison with urine osmolality in dogs
    Rudinsky, Adam J.
    Wellman, Maxey
    Tracy, Gaemia
    Stoltenberg, Lisa
    DiBartola, Stephen P.
    Chew, Dennis J.