The effect of ambient air temperature on whole-body bioelectrical impedance

被引:22
|
作者
Buono, MJ [1 ]
Burke, S [1 ]
Endemann, S [1 ]
Graham, H [1 ]
Gressard, C [1 ]
Griswold, L [1 ]
Michalewicz, B [1 ]
机构
[1] San Diego State Univ, Dept Exercise & Nutr Sci, San Diego, CA 92182 USA
关键词
bioelectric impedance; skin blood flow; ambient air temperature; skin temperature;
D O I
10.1088/0967-3334/25/1/011
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
It has previously been shown that extreme changes in ambient air temperature can affect whole-body bioelectrical impedance. The purpose of this study was to determine if more moderate changes in ambient air temperature, such as those experienced in most laboratory settings, would also affect bioelectric impedance analysis (BIA). In addition, to elucidate the mechanism responsible for changes in BIA with ambient air temperature, both skin blood flow (SBF) and the electrode-skin interface temperature were independently manipulated to determine their effect on BIA. During the first part of the study, nine healthy volunteers had their BIA measured in five different ambient air temperatures (15, 20, 25, 30 and 35degreesC). Mean BIA was 513 Omega under the 15degreesC condition and decreased significantly (p < 0.05) to 486 Omega in the 35 degreesC trial. However, no significant change was found in mean BIA between the 20 and 25 degreesC trials, which is the temperature range seen in most laboratories. Thus, moderate changes in ambient air temperature have only minor effects on BIA. In the second and third parts of the study, the electrode-skin interface temperature and SBF were independently manipulated using ice packs and electric heating pads placed over the four BIA electrodes. The results showed that BIA was inversely related to SBF (r = -0.95), and strongly suggest that changes in SBF, not electrode-skin interface temperature, are responsible for the changes seen in BIA.
引用
收藏
页码:119 / 123
页数:5
相关论文
共 50 条
  • [31] Segmental bioelectrical impedance analysis in children aged 8–12 y: 1. The assessment of whole-body composition
    NJ Fuller
    MS Fewtrell
    O Dewit
    M Elia
    JCK Wells
    International Journal of Obesity, 2002, 26 : 684 - 691
  • [32] Whole-body versus Segmental Bioelectrical Impedance Analysis in Patients with Edema of the Upper Limb After Breast Cancer Treatment
    Berlit, Sebastian
    Brade, Joachim
    Tuschy, Benjamin
    Foeldi, Etelka
    Walz-Eschenlohr, Ulrike
    Leweling, Hans
    Suetterlin, Marc
    ANTICANCER RESEARCH, 2013, 33 (08) : 3403 - 3406
  • [33] Whole-body impedance cardiography in the measurement of cardiac output
    Koobi, T
    Kaukinen, S
    Turjanmaa, VMH
    Uusitalo, AJ
    CRITICAL CARE MEDICINE, 1997, 25 (05) : 779 - 785
  • [34] Whole-body impedance control of wheeled mobile manipulators
    Dietrich, Alexander
    Bussmann, Kristin
    Petit, Florian
    Kotyczka, Paul
    Ott, Christian
    Lohmann, Boris
    Albu-Schaeffer, Alin
    AUTONOMOUS ROBOTS, 2016, 40 (03) : 505 - 517
  • [35] EFFECT OF BODY POSITIONS AND SPLINTS IN BIOELECTRICAL IMPEDANCE ANALYSIS
    PINILLA, JC
    WEBSTER, B
    BAETZ, M
    REEDER, B
    HATTORI, S
    LIU, L
    JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1992, 16 (05) : 408 - 412
  • [36] WHOLE-BODY AND SEGMENTAL BIOELECTRICAL PARAMETERS IN CHRONIC LIVER-DISEASE - EFFECT OF GENDER AND DISEASE STAGES
    PANELLA, C
    GUGLIELMI, FW
    MASTRONUZZI, T
    FRANCAVILLA, A
    HEPATOLOGY, 1995, 21 (02) : 352 - 358
  • [37] Effect of peritoneal fluid on whole body and segmental multiple frequency bioelectrical impedance in patients on peritoneal dialysis
    N Than
    G Woodrow
    B Oldroyd
    C Gonzalez
    JH Turney
    AM Brownjohn
    European Journal of Clinical Nutrition, 2000, 54 : 450 - 451
  • [38] Effect of peritoneal fluid on whole body and segmental multiple frequency bioelectrical impedance in patients an peritoneal dialysis
    Than, N
    Woodrow, G
    Oldroyd, B
    Gonzalez, C
    Turney, JH
    Brownjohn, AM
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2000, 54 (05) : 450 - 451
  • [39] Segmental bioelectrical impedance analysis in children aged 8-12y: 1. The assessment of whole-body composition
    Fuller, NJ
    Fewtrell, MS
    Dewit, O
    Elia, M
    Wells, JCK
    INTERNATIONAL JOURNAL OF OBESITY, 2002, 26 (05) : 684 - 691
  • [40] EFFECT OF ENVIRONMENTAL TEMPERATURE ON THE RESPONSE OF MICE TO WHOLE-BODY ROENTGEN RADIATION
    SMITH, WW
    HIGHMAN, BJ
    MITCHELL, JR