The effect of ambient air temperature on whole-body bioelectrical impedance

被引:22
|
作者
Buono, MJ [1 ]
Burke, S [1 ]
Endemann, S [1 ]
Graham, H [1 ]
Gressard, C [1 ]
Griswold, L [1 ]
Michalewicz, B [1 ]
机构
[1] San Diego State Univ, Dept Exercise & Nutr Sci, San Diego, CA 92182 USA
关键词
bioelectric impedance; skin blood flow; ambient air temperature; skin temperature;
D O I
10.1088/0967-3334/25/1/011
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
It has previously been shown that extreme changes in ambient air temperature can affect whole-body bioelectrical impedance. The purpose of this study was to determine if more moderate changes in ambient air temperature, such as those experienced in most laboratory settings, would also affect bioelectric impedance analysis (BIA). In addition, to elucidate the mechanism responsible for changes in BIA with ambient air temperature, both skin blood flow (SBF) and the electrode-skin interface temperature were independently manipulated to determine their effect on BIA. During the first part of the study, nine healthy volunteers had their BIA measured in five different ambient air temperatures (15, 20, 25, 30 and 35degreesC). Mean BIA was 513 Omega under the 15degreesC condition and decreased significantly (p < 0.05) to 486 Omega in the 35 degreesC trial. However, no significant change was found in mean BIA between the 20 and 25 degreesC trials, which is the temperature range seen in most laboratories. Thus, moderate changes in ambient air temperature have only minor effects on BIA. In the second and third parts of the study, the electrode-skin interface temperature and SBF were independently manipulated using ice packs and electric heating pads placed over the four BIA electrodes. The results showed that BIA was inversely related to SBF (r = -0.95), and strongly suggest that changes in SBF, not electrode-skin interface temperature, are responsible for the changes seen in BIA.
引用
收藏
页码:119 / 123
页数:5
相关论文
共 50 条
  • [21] Bioelectrical parameters of the whole human body obtained through bioelectrical impedance analysis
    Lafargue, AL
    Cabrales, LB
    Larramendi, RM
    BIOELECTROMAGNETICS, 2002, 23 (06) : 450 - 454
  • [22] Comparison of regional bioelectrical impedance (BI) devices to assess whole-body fatness (BF) in adults.
    Lukaski, HC
    Siders, WA
    FASEB JOURNAL, 2002, 16 (04): : A229 - A229
  • [23] BODY-COMPOSITION ANALYSIS BY BIOELECTRICAL IMPEDANCE - EFFECT OF SKIN TEMPERATURE
    CATON, JR
    MOLE, PA
    ADAMS, WC
    HEUSTIS, DS
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1988, 20 (05): : 489 - 491
  • [24] Bioelectrical impedance: The effect of exercise on bioelectrical impedance measurement and calculation of body composition
    Civar, S
    Ozer, K
    Gursel, E
    RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 2006, 77 (01) : A37 - A38
  • [25] TOTAL-BODY WATER AND WHOLE-BODY IMPEDANCE
    OBERLANDER, J
    CROSBY, L
    GIANDOMENICO, A
    STEIN, T
    MIKUTA, J
    MULLEN, J
    CLINICAL RESEARCH, 1980, 28 (03): : A621 - A621
  • [26] WHOLE-BODY AND SEGMENTAL BIOELECTRICAL-IMPEDANCE ANALYSIS IN PATIENTS WITH CIRRHOSIS OF THE LIVER - CHANGES AFTER TREATMENT OF ASCITES
    ZILLIKENS, MC
    VANDENBERG, JWO
    WILSON, JHP
    SWART, GR
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1992, 55 (03): : 621 - 625
  • [27] Whole-body impedance - What does it measure?
    Foster, KR
    Lukaski, HC
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1996, 64 (03): : 388 - 396
  • [28] Comments on "Bioelectrical parameters of the whole human body obtained through bioelectrical impedance analysis"
    Riu, PJ
    BIOELECTROMAGNETICS, 2004, 25 (01) : 69 - 71
  • [29] Whole-body Bioelectrical Impedance Analysis in Assessing Upper-limb Lymphedema After Breast Cancer Therapy
    Berlit, Sebastian
    Brade, Joachim
    Tuschy, Benjamin
    Hornemann, Amadeus
    Leweling, Hans
    Eghardt, Vanessa
    Suetterlin, Marc
    ANTICANCER RESEARCH, 2013, 33 (10) : 4553 - 4556
  • [30] CORRELATION OF WHOLE-BODY IMPEDANCE WITH TOTAL BODY WATER VOLUME
    HOFFER, EC
    MEADOR, CK
    SIMPSON, DC
    JOURNAL OF APPLIED PHYSIOLOGY, 1969, 27 (04) : 531 - &