Mesh fractal dimension detection on single-phrase-to-earth fault in the non-solidly earthed network

被引:0
|
作者
Zhao, CY [1 ]
Guo, YF [1 ]
机构
[1] N China Elect Power Univ, Sch Elect Engn, Baoding 071003, Hebei, Peoples R China
关键词
non-solidly earthed network; single-phrase-to-earth fault; identification of faulted line; fractal; mesh fractal dimension; GROUND NEUTRAL SYSTEM; LOCATION;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The most frequent fault type is single-phrase-to-earth fault in the non-solidly earthed network. After analyzing the characteristics of the existing methods about identifying the faulted fine in the non-solidly earthed network, the characteristics of the fault-current waveforms are analyzed deeply and a new method using mesh fractal dimension is presented. The mesh fractal dimension of zero-order currents of faulty line and normal line are calculated and compared, the faulted line can be determined correctly. The selecting result on fault feeder is out of all relation to the CT's polarity. The new method is right to be applied to neutral point unearthed system and neutral point ineffective earthed system. The fault line can be confirmed even when intermittent arc earth faults occur. Simulations of various earth faults under different conditions are performed using MATLAB. The results show the method is feasible and effective.
引用
收藏
页码:752 / 756
页数:5
相关论文
共 32 条
  • [21] Faulted Line Detection Using Sampled Data and GBDT for Non-solidly Earthed System
    Yuan, Jiawei
    Feng, Guang
    Chen, Ming
    Xu, Mingming
    Jiao, Zaibin
    2020 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2020,
  • [22] Fault line identification and fault section location based on transient zero-module combination admittance in non-solidly earthed network
    Sun, Bo
    Sun, Tong-Jing
    Xue, Yong-Duan
    Xu, Bing-Yin
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (22): : 57 - 62
  • [23] New fault locating method based on transient vector field for single phase grounding fault in non-solidly earthed overhead lines
    Shandong University, Jinan 250061, China
    不详
    不详
    Dianli Xitong Zidonghue, 2009, 19 (71-76): : 71 - 76
  • [24] Fault Section Location Method Based on Fuzzy Self-Correction Bat Algorithm in Non-solidly Earthed Distribution Network
    Jiang, Kai
    Tong, Xiaoyang
    PROCEEDINGS OF 2017 2ND INTERNATIONAL CONFERENCE ON POWER AND RENEWABLE ENERGY (ICPRE), 2017, : 485 - 489
  • [25] New fault locating method based on approximate entropy of transient zero-module current in non-solidly earthed network
    Sun, Bo
    Xu, Bingyin
    Sun, Tongjing
    Xue, Yongduan
    Liu, Shiguang
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2009, 33 (20): : 83 - 87
  • [26] Study on single-phase earthed faulty feeder selection methods in non-solidly grounded systems
    Zhang, Xinhui
    Xu, Bingyin
    Pan, Zhencun
    Wei, Peiyu
    2008 THIRD INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1-6, 2008, : 1836 - +
  • [27] Grounded Incipient Fault Detection Based on Compound Criterion in Non-solidly Grounding System
    Chu, Tianxin
    Zhang, Wenhai
    Qu, Ke
    Zhang, Shu
    Xiao, Xianyong
    Wang, Yang
    Gaodianya Jishu/High Voltage Engineering, 2022, 48 (03): : 1022 - 1031
  • [28] Fault line selecting method in non-solidly-earthed network based on SCADA system
    Zhu T.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2019, 47 (13): : 141 - 147
  • [29] Earth fault protection using transient signals in non-solid earthed. network
    Xue, YD
    Xu, BY
    Chen, Y
    Feng, ZR
    Gale, P
    POWERCON 2002: INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS 1-4, PROCEEDINGS, 2002, : 1763 - 1767
  • [30] Principle of directional earth fault protection using zero sequence transients in non-solid earthed network
    Xue, Yong-Duan
    Xu, Bing-Yin
    Feng, Zu-Ren
    Li, Tian-You
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2003, 23 (07): : 51 - 56