A Comparative Evaluation of Transesophageal and Transthoracic Echocardiography for Measurement of Left Ventricular Systolic Strain Using Speckle Tracking

被引:49
|
作者
Marcucci, Carlo E. [1 ]
Samad, Zainab [2 ]
Rivera, Jose [2 ]
Adams, David B. [2 ]
Philips-Bute, Barbara G. [1 ]
Mahajan, Aman [4 ]
Douglas, Pamela S. [3 ]
Aronson, Solomon [1 ]
Mackensen, G. Burkhard [1 ]
Podgoreanu, Mihai V. [1 ]
Mathew, Joseph P. [1 ]
Swaminathan, Madhav [1 ]
机构
[1] Duke Univ, Med Ctr, Div Cardiothorac Anesthesiol & Crit Care Med, Dept Anesthesiol, Durham, NC 27710 USA
[2] Duke Univ, Med Ctr, Cardiac Diagnost Unit, Div Cardiol,Dept Med, Durham, NC 27710 USA
[3] Duke Univ, Med Ctr, Duke Clin Res Inst, Durham, NC 27710 USA
[4] Univ Calif Los Angeles, David Geffen Sch Med, Div Cardiothorac Anesthesiol, Dept Anesthesiol, Los Angeles, CA 90095 USA
关键词
coronary artery bypass surgery; transesophageal echocardiography; myocardial contraction; strain; speckle tracking; 2-DIMENSIONAL SPECKLE; TISSUE VELOCITY; DYSSYNCHRONY; VALIDATION; TORSION;
D O I
10.1053/j.jvca.2011.06.002
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: The authors hypothesized that the measurement of strain by speckle tracking with transesophageal echocardiography (TEE) is feasible and comparable to transthoracic echocardiography (TTE). Design: A prospective observational comparative study. Setting: A university hospital. Participants: Adult patients undergoing elective cardiac surgery. Interventions: Structured intraoperative TTE and TEE examination. Measurements and Main Results: Images were obtained after the induction of anesthesia from 25 patients to enable speckle tracking of the left ventricle in comparable short- and long-axis (SAX and LAX) views using TTE and TEE. Left ventricular strain was measured offline using both modalities and correlation assessed using the Pearson test with assessment of bias using the Bland-Altman method. Significantly more segments were tracked by TEE than TTE in LAX views but not SAX views. Correlation was moderate between TTE and TEE (r = 0.5-0.6) for longitudinal strain in the LAX views, whereas it was poor for regional radial strain (r = 0.07). Correlation for global circumferential strain was higher for the apical SAX views (r = 0.7) than the basal or mid-SAX views. Speckle tracking by TEE showed excellent reproducibility with small bias. Conclusions: Strain measured by speckle tracking in TEE correlated moderately with TTE for global strain and poorly for regional strain. This may be explained by differences in scanning frequency and other imaging factors. Nevertheless, because of the high degree of reproducibility, it may be a useful tool to quantify intraoperative changes in ventricular function with TEE. However, equivalence between TTE and TEE cannot be assumed, and limits of comparability should be recognized. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:17 / 25
页数:9
相关论文
共 50 条
  • [1] Evaluation of the left ventricular systolic strain in hypocalcemic infants with two-dimensional speckle tracking echocardiography
    Aboelata, Shaimaa
    Elmarsafawy, Hala
    Atwa, Mohamed A.
    Wahba, Yahya
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2022, 39 (04): : 568 - 575
  • [2] Assessing Left Ventricular Early Diastolic Velocities With Tissue Doppler and Speckle Tracking by Transesophageal and Transthoracic Echocardiography
    Mauermann, Eckhard
    Bouchez, Stefaan
    Bove, Thierry
    Vandenheuvel, Michael
    Wouters, Patrick
    ANESTHESIA AND ANALGESIA, 2021, 132 (05): : 1400 - 1409
  • [3] Evaluation of the left venticular systolic function with the measurement of global longitudinal strain by Speckle tracking echocardiography in anaphylaxis
    Demir, Semra
    Atici, Adem
    Coskun, Raif
    Olgac, Muge
    Unal, Derya
    Sarikaya, Remzi
    Gelincik, Asli
    Colakoglu, Bahattin
    Oflaz, Huseyin
    Sonsoz, Mehmet Rasih
    Buyukorturk, Suna
    ASIA PACIFIC ALLERGY, 2018, 8 (04)
  • [4] Evaluation of Global Left Ventricular Systolic Function Using Three-Dimensional Echocardiography Speckle-Tracking Strain Parameters
    Reant, Patricia
    Barbot, Laurence
    Touche, Cecile
    Dijos, Marina
    Arsac, Florence
    Pillois, Xavier
    Landelle, Mathieu
    Roudaut, Raymond
    Lafitte, Stephane
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2012, 25 (01) : 68 - 79
  • [5] Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
    Hensel, Kai O.
    Wilke, Lucia
    Heusch, Andreas
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2016, (116):
  • [6] Evaluation of Subclinical Left Ventricular Systolic Dysfunction in Chronic Asymptomatic Alcoholics by Speckle Tracking Echocardiography
    Kucuk, Murathan
    Oncel, Can Ramazan
    Yjldjrjm, Aytul Belgi
    Canan, Fatih
    Kuloglu, Mehmet Murat
    BIOMED RESEARCH INTERNATIONAL, 2017, 2017
  • [7] Left Ventricular Systolic Strain of the Cardiac Allograft Evaluated with Three-dimensional Speckle Tracking Echocardiography
    刘红云
    邓又斌
    刘琨
    李阳
    汤乔颖
    魏翔
    昌盛
    卢峡
    Current Medical Science, 2013, (05) : 765 - 769
  • [8] Left Ventricular Systolic Strain of the Cardiac Allograft Evaluated with Three-dimensional Speckle Tracking Echocardiography
    刘红云
    邓又斌
    刘琨
    李阳
    汤乔颖
    魏翔
    昌盛
    卢峡
    Journal of Huazhong University of Science and Technology(Medical Sciences), 2013, 33 (05) : 765 - 769
  • [9] An automated method for measurement of left ventricular torsion using speckle tracking echocardiography
    Harrison, J. L.
    Borg, A. N.
    Laws, C. D.
    Ray, S. G.
    EUROPEAN HEART JOURNAL, 2007, 28 : 494 - 494
  • [10] Left ventricular systolic strain of the cardiac allograft evaluated with three-dimensional speckle tracking echocardiography
    Liu, Hong-yun
    Deng, You-bin
    Liu, Kun
    Li, Yang
    Tang, Qiao-ying
    Wei, Xiang
    Chang, Sheng
    Lu, Xia
    JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2013, 33 (05) : 765 - 769