Evaluation of Global Left Ventricular Systolic Function Using Three-Dimensional Echocardiography Speckle-Tracking Strain Parameters

被引:149
|
作者
Reant, Patricia [1 ]
Barbot, Laurence [1 ]
Touche, Cecile [1 ]
Dijos, Marina [1 ]
Arsac, Florence [1 ]
Pillois, Xavier [1 ]
Landelle, Mathieu [1 ]
Roudaut, Raymond [1 ]
Lafitte, Stephane [1 ]
机构
[1] Bordeaux Univ, Cardiol Hosp CHU Bordeaux CIC0005, Pessac, France
关键词
Myocardial deformation; Systolic function; Speckle-tracking echocardiography; 3D echocardiography; 2-DIMENSIONAL STRAIN; MYOCARDIAL-FUNCTION; AREA STRAIN; CARDIOMYOPATHY; DEFORMATION;
D O I
10.1016/j.echo.2011.10.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The aim of this study was to evaluate the capacity and reproducibility of three-dimensional echocardiographic (3DE) strain parameters in the assessment of global left ventricular (LV) systolic function. Methods: A total of 128 subjects with differing LV ejection fractions were investigated using two-dimensional echocardiographic (2DE) and 3DE strains. Three-dimensional echocardiographic strain allows obtaining longitudinal, circumferential, radial, and area strains. First, values of global longitudinal strain (GLS) by 2DE and 3DE speckle-tracking analyses were compared. Thereafter, 3DE strain parameters were correlated with LV ejection fraction and indexed output. Last, the variability of 3DE versus 2DE strain measurements as well as recorded time of analysis were assessed. Results: After excluding 21 patients for insufficient image quality, four for arrhythmia, two for severe valvular disease, and one for severe dyspnea, the final population consisted of 100 patients. Comparison between 2DE and 3DE GLS revealed high correspondence (r = 0.91, y = 1.04x -0.71) and mean error measurement of -1.3% (95% confidence interval, -5.7 to 3.2). Among strain parameters, global area strain exhibited the highest correlation with LV ejection fraction (y = -1.65 + 10.4, r = -0.92, P < .001). Intraobserver measurement variability proved acceptable: 8% for GLS (vs 6% on 2DE analysis), 7% for circumferential strain (vs 15% on 2DE analysis), 7% for radial strain (vs 33% on 2DE analysis), and 5% for global area strain. The mean error between two measurements was lower with 3DE than 2DE analysis for circumferential and radial strains but similar for GLS. The mean time of analysis was of 117 +/- 16 sec for 3DE analysis, which was 25% less than for 2DE analysis (P < .001). Conclusions: Of all strain parameters, new 3DE area strain correlated best with common LV systolic function parameters and is thus the most promising approach, while all 3DE strain markers exhibited good reproducibility. (J Am Soc Echocardiogr 2012;25:68-79.)
引用
收藏
页码:68 / 79
页数:12
相关论文
共 50 条
  • [1] Evaluation of global left ventricular systolic function in patients with heart failure using three-dimensional speckle-tracking echocardiography
    Luo, X. X.
    Fang, F.
    Lee, P. W.
    Li, S.
    Zhang, Z. H.
    Lam, Y. Y.
    Sanderson, J. E.
    Kwong, J. S. W.
    Yu, C. M.
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 163 : S21 - S22
  • [2] Global area strain is a new and robust parameter to characterize left ventricular systolic function by three-dimensional speckle-tracking echocardiography
    Muraru, D.
    Cucchini, U.
    Badano, L. P.
    Solda', E.
    Tuveri, F.
    Al Nono, O.
    Sarais, C.
    Iliceto, S.
    [J]. EUROPEAN HEART JOURNAL, 2011, 32 : 207 - 207
  • [3] Use of Three-Dimensional Speckle-Tracking Echocardiography for Quantitative Assessment of Global Left Ventricular Function: A Comparative Study to Three-Dimensional Echocardiography
    Luis, Sushil A.
    Yamada, Akira
    Khandheria, Bijoy K.
    Speranza, Vicki
    Benjamin, Anthony
    Ischenko, Matthew
    Platts, David G.
    Hamilton-Craig, Christian R.
    Haseler, Luke
    Burstow, Darryl
    Chan, Jonathan
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2014, 27 (03) : 285 - 291
  • [4] Assessment of left ventricular systolic function in patients with iron deficiency anemia by three-dimensional speckle-tracking echocardiography
    Zhou, Qiao
    Shen, Jiaqi
    Liu, Yue
    Luo, Runlan
    Tan, Bijun
    Li, Guangsen
    [J]. ANATOLIAN JOURNAL OF CARDIOLOGY, 2017, 18 (03): : 194 - 199
  • [5] Interinstitutional Measurements of Left Ventricular Volumes, Speckle-Tracking Strain, and Dyssynchrony Using Three-Dimensional Echocardiography
    Tsang, Wendy
    Kenny, Cliona
    Adhya, Shaumik
    Kapetanakis, Stam
    Weinert, Lynn
    Lang, Roberto M.
    Monaghan, Mark
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2013, 26 (11) : 1253 - 1257
  • [6] Evaluation of Left Ventricular Function by Three-Dimensional Speckle-Tracking Echocardiography in Patients with Chronic Kidney Failure
    Wang, Yu-bo
    Huang, Hui
    Lin, Shan
    Hao, Mei-jia
    He, Lu-jiao
    Liu, Kun
    Bi, Xiao-jun
    [J]. CURRENT MEDICAL SCIENCE, 2022, 42 (04) : 895 - 901
  • [7] Evaluation of Left Ventricular Function by Three-Dimensional Speckle-Tracking Echocardiography in Patients with Chronic Kidney Failure
    Yu-bo Wang
    Hui Huang
    Shan Lin
    Mei-jia Hao
    Lu-jiao He
    Kun Liu
    Xiao-jun Bi
    [J]. Current Medical Science, 2022, 42 : 895 - 901
  • [8] Left Ventricular Systolic Strain of the Cardiac Allograft Evaluated with Three-dimensional Speckle Tracking Echocardiography
    刘红云
    邓又斌
    刘琨
    李阳
    汤乔颖
    魏翔
    昌盛
    卢峡
    [J]. Current Medical Science, 2013, (05) : 765 - 769
  • [9] Left Ventricular Systolic Strain of the Cardiac Allograft Evaluated with Three-dimensional Speckle Tracking Echocardiography
    刘红云
    邓又斌
    刘琨
    李阳
    汤乔颖
    魏翔
    昌盛
    卢峡
    [J]. JournalofHuazhongUniversityofScienceandTechnology(MedicalSciences), 2013, 33 (05) : 765 - 769
  • [10] Left ventricular systolic strain of the cardiac allograft evaluated with three-dimensional speckle tracking echocardiography
    Liu, Hong-yun
    Deng, You-bin
    Liu, Kun
    Li, Yang
    Tang, Qiao-ying
    Wei, Xiang
    Chang, Sheng
    Lu, Xia
    [J]. JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2013, 33 (05) : 765 - 769