Left ventricular systolic strain of the cardiac allograft evaluated with three-dimensional speckle tracking echocardiography

被引:3
|
作者
Liu, Hong-yun [1 ]
Deng, You-bin [1 ]
Liu, Kun [1 ]
Li, Yang [1 ]
Tang, Qiao-ying [1 ]
Wei, Xiang [2 ]
Chang, Sheng [3 ]
Lu, Xia [3 ]
机构
[1] Huazhong Univ Sci & Technol, Tongji Hosp, Dept Med Ultrasound, Tongji Med Coll, Wuhan 430030, Peoples R China
[2] Huazhong Univ Sci & Technol, Tongji Hosp, Dept Cardiovasc Surg, Tongji Med Coll, Wuhan 430030, Peoples R China
[3] Huazhong Univ Sci & Technol, Inst Organ Transplantat, Tongji Hosp, Tongji Med Coll, Wuhan 430030, Peoples R China
关键词
three-dimensional echocardiography; speckle tracking imaging; heart transplantation; AREA STRAIN; PERICARDIUM; ABSENCE; HEART;
D O I
10.1007/s11596-013-1194-8
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Three-dimensional speckle tracking echocardiography was employed to evaluate the changes of left ventricular systolic strain in 23 heart transplant recipients at 1st, 3rd, 6th and 12th month after heart transplantation, and 23 healthy subjects served as controls. The three-dimensional full-volume echocardiographic images of left ventricle were recorded and then were analyzed using EchoPAC software. The strain curves and peak systolic strain values for each segment and overall left ventricular wall were obtained. Left ventricular global peak longitudinal strain (GPSL), global peak radial strain (GPSR), global peak circumferential strain (GPSC) and global peak area strain (GPSA) were measured and then statistically analyzed. There were no significant differences in left ventricular ejection fraction (LVEF) and cardiac output (CO) between heart transplant recipients and controls. The GPSL in heart transplant recipients at 1st month after surgery was significantly lower than that in controls, but close to the normal value at 3rd month after surgery and later. The GPSC, GPSA and GPSR were significantly lower in heart transplant recipients at 1st, 3rd, 6th and 12th month after surgery than those in controls. It is suggested that three-dimensional speckle tracking echocardiography can be used for monitoring changes of left ventricular systolic strains and evaluating left ventricular systolic function in cardiac allograft.
引用
收藏
页码:765 / 769
页数:5
相关论文
共 50 条
  • [1] Left Ventricular Systolic Strain of the Cardiac Allograft Evaluated with Three-dimensional Speckle Tracking Echocardiography
    刘红云
    邓又斌
    刘琨
    李阳
    汤乔颖
    魏翔
    昌盛
    卢峡
    [J]. JournalofHuazhongUniversityofScienceandTechnology(MedicalSciences)., 2013, 33 (05) - 769
  • [2] Left Ventricular Systolic Strain of the Cardiac Allograft Evaluated with Three-dimensional Speckle Tracking Echocardiography
    刘红云
    邓又斌
    刘琨
    李阳
    汤乔颖
    魏翔
    昌盛
    卢峡
    [J]. Current Medical Science, 2013, (05) : 765 - 769
  • [3] Left ventricular systolic strain of the cardiac allograft evaluated with three-dimensional speckle tracking echocardiography
    Hong-yun Liu
    You-bin Deng
    Kun Liu
    Yang Li
    Qiao-ying Tang
    Xiang Wei
    Sheng Chang
    Xia Lu
    [J]. Journal of Huazhong University of Science and Technology [Medical Sciences], 2013, 33 : 765 - 769
  • [4] Evaluation of Global Left Ventricular Systolic Function Using Three-Dimensional Echocardiography Speckle-Tracking Strain Parameters
    Reant, Patricia
    Barbot, Laurence
    Touche, Cecile
    Dijos, Marina
    Arsac, Florence
    Pillois, Xavier
    Landelle, Mathieu
    Roudaut, Raymond
    Lafitte, Stephane
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2012, 25 (01) : 68 - 79
  • [5] Left ventricular noncompaction highlighted by three-dimensional and speckle tracking echocardiography
    Hotta, Viviane Tiemi
    Baptista Martinelli, Luiz Mario
    Moises, Valdir Ambrosio
    Mady, Charles
    Fernandes, Fabio
    [J]. EINSTEIN-SAO PAULO, 2022, 20 : eAI6853
  • [6] Global area strain is a new and robust parameter to characterize left ventricular systolic function by three-dimensional speckle-tracking echocardiography
    Muraru, D.
    Cucchini, U.
    Badano, L. P.
    Solda', E.
    Tuveri, F.
    Al Nono, O.
    Sarais, C.
    Iliceto, S.
    [J]. EUROPEAN HEART JOURNAL, 2011, 32 : 207 - 207
  • [7] The variation of left ventricular strain after aortic valve replacement by three-dimensional speckle tracking echocardiography
    Cheng, L. L.
    Shu, X. H.
    Chen, Y. L.
    Wang, C. S.
    Ge, J. B.
    [J]. EUROPEAN HEART JOURNAL, 2014, 35 : 502 - 503
  • [8] LEFT VENTRICULAR MYOCARDIAL STRAIN BY THREE-DIMENSIONAL SPECKLE-TRACKING ECHOCARDIOGRAPHY IN HEALTHY VOLUNTEERS: A NORMATIVE STUDY
    Muraru, Denisa
    Cucchini, Umberto
    Padayattil-Jose, Seena
    Mihaila, Sorina
    Miglioranza, Marcelo
    Peluso, Diletta
    Cecchetto, Antonella
    Casablanca, Simona
    Iliceto, Sabino
    Badano, Luigi
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A1167 - A1167
  • [9] Assessment of left ventricular systolic function in patients with iron deficiency anemia by three-dimensional speckle-tracking echocardiography
    Zhou, Qiao
    Shen, Jiaqi
    Liu, Yue
    Luo, Runlan
    Tan, Bijun
    Li, Guangsen
    [J]. ANATOLIAN JOURNAL OF CARDIOLOGY, 2017, 18 (03): : 194 - 199
  • [10] Predictors of pacing induced left ventricular dysfunction and cardiomyopathy assessed by three-dimensional echocardiography and speckle tracking strain
    Moustafa Dawood
    Eman Elsharkawy
    Mohamed Ayman Abdel-Hay
    Moustafa Nawar
    [J]. The Egyptian Heart Journal, 73