Operation of a Cryogenic Current Comparator in Presence of Mechanical Vibrations

被引:0
|
作者
Bierzychudek, Marcos E. [1 ,2 ]
Goetz, Martin [3 ]
Schmelzer, Martin [3 ]
机构
[1] Inst Nacl Tecnol Ind, Buenos Aires, DF, Argentina
[2] Inst Tecnol Buenos Aires, Buenos Aires, DF, Argentina
[3] Phys Tech Bundesanstalt, Braunschweig, Germany
关键词
Closed loop systems; control system analysis; frequency response; robustness; SQUIDs; system identification; vibration measurement;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In measurements with cryogenic current comparators (CCCs), robustness against mechanical distortions is an issue. Sources of distortions are part of the experimental environment, efficient suppression is difficult. In a test setup, we intentionally applied mechanical vibrations to a CCC probe. In the 10 Hz to 3 kHz range, the frequency response of the SQUID detector's output signal was recorded for an integrative and an H-infinity-controller. When applying vibrations at fixed frequency, the stability of the SQUID's locking depended on the chosen controller, but systematic influence on the result of a 12.9 k Omega vs. 100 Omega resistance comparison was not found.
引用
收藏
页数:2
相关论文
共 50 条
  • [1] Influence of Mechanical Deformations on the Performance of a Coaxial Shield for a Cryogenic Current Comparator
    Marsic, Nicolas
    Mueller, Wolfgang F. O.
    Tympel, Volker
    Stoehlker, Thomas
    Stapelfeld, Max
    Schmidl, Frank
    Schmelz, Matthias
    Zakosarenko, Vyacheslav
    Stolz, Ronny
    Haider, David
    Sieber, Thomas
    Schwickert, Marcus
    De Gersem, Herbert
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2022, 32 (09)
  • [2] Ultimate current resolution of a cryogenic current comparator
    Sesé, J
    Camón, A
    Rillo, C
    Rietveld, G
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1999, 48 (06) : 1306 - 1313
  • [3] CRYOGENIC CURRENT COMPARATOR WITH INCREASED RESOLUTION
    VANDERWEL, W
    MOOIJ, JE
    HARMANS, CJPM
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (04): : 624 - 626
  • [4] Cryogenic current comparator implementation at CENAM
    Sánchez, C
    Avilés, D
    Hernández, D
    Durán, G
    [J]. 2000 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2000, : 96 - 97
  • [5] LEAKAGE CURRENT DETECTION IN CRYOGENIC CURRENT COMPARATOR BRIDGES
    ELMQUIST, RE
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1993, 42 (02) : 167 - 169
  • [6] Improving the stability of cryogenic current comparator setups
    Drung, D.
    Goetz, M.
    Pesel, E.
    Storm, J. -H
    Assmann, C.
    Peters, M.
    Schurig, Th
    [J]. SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2009, 22 (11):
  • [7] On forward estimate of the sensitivity of a cryogenic current comparator
    Frantsuz, ET
    [J]. METROLOGIA, 1998, 35 (06) : 847 - 851
  • [8] Simplified calculus for the design of a cryogenic current comparator
    Sesé, J
    Bartolomé, E
    Camón, A
    Flokstra, J
    Rietveld, G
    Rillo, C
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2003, 52 (02) : 612 - 616
  • [9] Thin-film cryogenic current comparator
    Seppä, H
    Satrapinksi, A
    Kiviranta, M
    Virkki, V
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1999, 48 (02) : 365 - 369
  • [10] Method for the Calibration of Cryogenic Current Comparator Ratios
    Lu, Yunfeng
    Zhao, Jianting
    He, Qing
    [J]. 2020 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM), 2020,