Method for the Calibration of Cryogenic Current Comparator Ratios

被引:0
|
作者
Lu, Yunfeng [1 ]
Zhao, Jianting [1 ]
He, Qing [1 ]
机构
[1] Natl Inst Metrol, Beijing 100029, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
Measurement; calibration method; winding ratio; CCC;
D O I
10.1109/cpem49742.2020.9191884
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes a method for calibrating binary Cryogenic Current Comparator(CCC) winding ratios. The method,described as a step-up technique, involves calibrating the CCC winding first on a 1:1 ratio. By adding an additional 1-turn as a reference,the comparison of two 1-turn windings can be realized, then the two 1-turn windings are added and compared to the 2-turns winding. This process continues until the 2(n)-turns winding is checked. The CCC ratio error and its uncertainty are also analyzed in this paper. Preliminary experiment shows that the ratio 400(2(8)+2(7)+2(4)):4(2(2)) error is below 5 part in 10(11).
引用
收藏
页数:2
相关论文
共 50 条
  • [2] Aspects of Application and Calibration of a Binary Compensation Unit for Cryogenic Current Comparator Setups
    Drung, Dietmar
    Goetz, Martin
    Pesel, Eckart
    Barthelmess, Henry J.
    Hinnrichs, Colmar
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2013, 62 (10) : 2820 - 2827
  • [3] Ultimate current resolution of a cryogenic current comparator
    Sesé, J
    Camón, A
    Rillo, C
    Rietveld, G
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1999, 48 (06) : 1306 - 1313
  • [4] Calibration of ultrastable low-noise current amplifiers without direct use of a cryogenic current comparator
    Goetz, M.
    Drung, D.
    Krause, C.
    Mortara, A.
    [J]. METROLOGIA, 2020, 57 (05)
  • [5] Calibration of the Second Generation of Ultrastable Low-Noise Current Amplifiers Using a Cryogenic Current Comparator
    Goetz, Martin
    Drung, Dietmar
    Krause, Christian
    Becker, Ulrich
    Scherer, Hansjorg
    [J]. 2018 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2018), 2018,
  • [6] CRYOGENIC CURRENT COMPARATOR WITH INCREASED RESOLUTION
    VANDERWEL, W
    MOOIJ, JE
    HARMANS, CJPM
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (04): : 624 - 626
  • [7] Cryogenic current comparator implementation at CENAM
    Sánchez, C
    Avilés, D
    Hernández, D
    Durán, G
    [J]. 2000 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2000, : 96 - 97
  • [8] LEAKAGE CURRENT DETECTION IN CRYOGENIC CURRENT COMPARATOR BRIDGES
    ELMQUIST, RE
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1993, 42 (02) : 167 - 169
  • [9] Improving the stability of cryogenic current comparator setups
    Drung, D.
    Goetz, M.
    Pesel, E.
    Storm, J. -H
    Assmann, C.
    Peters, M.
    Schurig, Th
    [J]. SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2009, 22 (11):
  • [10] On forward estimate of the sensitivity of a cryogenic current comparator
    Frantsuz, ET
    [J]. METROLOGIA, 1998, 35 (06) : 847 - 851