Potentiometric pH measurements in high subcritical and supercritical aqueous solutions

被引:18
|
作者
Lvov, SN [1 ]
Gao, H [1 ]
Kouznetsov, D [1 ]
Balachov, I [1 ]
Macdonald, DD [1 ]
机构
[1] Penn State Univ, Ctr Adv Mat, University Pk, PA 16802 USA
关键词
supercritical aqueous solutions; pH measurements; reference electrode;
D O I
10.1016/S0378-3812(98)00298-2
中图分类号
O414.1 [热力学];
学科分类号
摘要
An operational electrochemical thermocell is proposed for potentiometric pH measurements in high subcritical and supercritical aqueous solutions. The thermocell consists of the silver-silver chloride flow-through external pressure-balanced reference electrode (FTEPBRE) and the flow-through platinum-hydrogen pH sensor. Using this thermocell, we have measured the potentials of the thermocell for a few HCl(aq) and NaOH(aq) solutions of different concentrations and derived the corresponding pH differences (Delta pH) over a wide range of temperatures from 25 to 400 degrees C at pressures between 27.5 and 33.8 MPa. Comparison of the experimentally derived and theoretically calculated Delta pH values clearly demonstrates an ability of the thermocell to measure pH with accuracy better than +/-0.1 units, and this result in turn demonstrates the viability of the FTEPBRE as a versatile reference electrode for use at high subcritical and supercritical temperatures. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:515 / 523
页数:9
相关论文
共 50 条
  • [31] An efficient fluorescent probe for ratiometric pH measurements in aqueous solutions
    Charier, S
    Ruel, O
    Baudin, JB
    Alcor, D
    Allemand, JF
    Meglio, A
    Jullien, L
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2004, 43 (36) : 4785 - 4788
  • [32] Chemically modified electrodes with polyanyline for pH measurements in aqueous solutions
    Tanase, I
    Nidelea, M
    Buleandra, W
    REVISTA DE CHIMIE, 2003, 54 (03): : 202 - 207
  • [33] Potentiometric pH measurements in acidic sulfate solutions at 250 °C relevant to pressure leaching
    Seneviratne, DS
    Papangelakis, VG
    Zhou, XY
    Lvov, SN
    HYDROMETALLURGY, 2003, 68 (1-3) : 131 - 139
  • [34] Adaptation of potentiometric measurements to continuous estimation of copper in aqueous solutions with fluctuating physicochemical parameters
    Tisserand, E.
    Schweitzer, P.
    Tisserand, P.
    Cecile, J.L.
    Revue des Sciences de l'Eau, 2001, 14 (02): : 157 - 172
  • [35] Volume of Activation for the Corrosion of Type 304 Stainless Steel in High Subcritical and Supercritical Aqueous Systems
    Macdonald, D. D.
    Guan, X.
    CORROSION, 2009, 65 (07) : 427 - 437
  • [36] Oxidation of an azo dye in subcritical aqueous solutions
    Donlagic, J.
    Levec, J.
    Industrial and Engineering Chemistry Research, 1997, 36 (09): : 3480 - 3486
  • [37] Oxidation of an azo dye in subcritical aqueous solutions
    Donlagic, J
    Levec, J
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1997, 36 (09) : 3480 - 3486
  • [38] In-situ electrochemical impedance measurements of corroding stainless steel in high subcritical and supercritical water
    Macak, J.
    Novotny, R.
    Sajdl, P.
    Bystriansky, V.
    Tuma, L.
    Novak, M.
    CORROSION SCIENCE, 2019, 150 : 9 - 16
  • [39] SIMULATION OF SUPERCRITICAL WATER AND OF SUPERCRITICAL AQUEOUS-SOLUTIONS
    CUMMINGS, PT
    COCHRAN, HD
    SIMONSON, JM
    MESMER, RE
    KARABORNI, S
    JOURNAL OF CHEMICAL PHYSICS, 1991, 94 (08): : 5606 - 5621
  • [40] Structure of subcritical and supercritical hydrogen-bonded liquids and solutions
    Yamaguchi, T
    JOURNAL OF MOLECULAR LIQUIDS, 1998, 78 (1-2) : 43 - 50