Potentiometric pH measurements in high subcritical and supercritical aqueous solutions

被引:18
|
作者
Lvov, SN [1 ]
Gao, H [1 ]
Kouznetsov, D [1 ]
Balachov, I [1 ]
Macdonald, DD [1 ]
机构
[1] Penn State Univ, Ctr Adv Mat, University Pk, PA 16802 USA
关键词
supercritical aqueous solutions; pH measurements; reference electrode;
D O I
10.1016/S0378-3812(98)00298-2
中图分类号
O414.1 [热力学];
学科分类号
摘要
An operational electrochemical thermocell is proposed for potentiometric pH measurements in high subcritical and supercritical aqueous solutions. The thermocell consists of the silver-silver chloride flow-through external pressure-balanced reference electrode (FTEPBRE) and the flow-through platinum-hydrogen pH sensor. Using this thermocell, we have measured the potentials of the thermocell for a few HCl(aq) and NaOH(aq) solutions of different concentrations and derived the corresponding pH differences (Delta pH) over a wide range of temperatures from 25 to 400 degrees C at pressures between 27.5 and 33.8 MPa. Comparison of the experimentally derived and theoretically calculated Delta pH values clearly demonstrates an ability of the thermocell to measure pH with accuracy better than +/-0.1 units, and this result in turn demonstrates the viability of the FTEPBRE as a versatile reference electrode for use at high subcritical and supercritical temperatures. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:515 / 523
页数:9
相关论文
共 50 条
  • [21] POTENTIOMETRIC PH STUDY OF THE INTERACTION OF SAMARIUM(III) WITH HYDRAZINE IN AQUEOUS-SOLUTIONS
    ALIEV, RY
    MUSAEV, DB
    KULIEV, AD
    KLYUCHNIKOV, NG
    SOVIET ELECTROCHEMISTRY, 1979, 15 (10): : 1339 - 1341
  • [23] Mathematical modeling of pH-potentiometric measurements in tungsten-vanadium solutions
    Rozantsev, GM
    Sazonova, OI
    Kholin, YV
    RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY, 2002, 76 (03): : 384 - 390
  • [24] Mathematical modeling of pH-potentiometric measurements in tungsten-vanadium solutions
    Rozantsev, G.M.
    Sazonova, O.I.
    Kholin, Yu.V.
    Zhurnal Fizicheskoj Khimii, 2002, 76 (03): : 459 - 466
  • [25] Potentiometric and spectrophotometric measurements of stability constants of complexes in non-aqueous solutions
    Gorodkiewicz, E
    Figaszewski, Z
    CHEMIA ANALITYCZNA, 1998, 43 (03): : 445 - 455
  • [26] Solid-contacted potentiometric electrodes for measurements of sulfate ions in aqueous solutions
    Berthold, M
    Jahn, H
    Kaden, H
    ACTA HYDROCHIMICA ET HYDROBIOLOGICA, 2001, 29 (04): : 219 - 226
  • [27] Electrochemical corrosion studies in high-temperature subcritical and supercritical aqueous environments.
    Lvov, SN
    Zhou, XY
    Wei, X
    Ulyanov, SM
    Macdonald, DD
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1999, 218 : U1066 - U1066
  • [28] Improving the quality of potentiometric pH measurements
    M. J. Guiomar
    H. M. Lito
    M. Filomena Camões
    Catarina M. Viçoso
    Accreditation and Quality Assurance, 2007, 12 : 447 - 453
  • [29] Improving the quality of potentiometric pH measurements
    Guiomar, M. J.
    Lito, H. M.
    Camoes, M. Filomena
    Vicoso, Catarina M.
    ACCREDITATION AND QUALITY ASSURANCE, 2007, 12 (09) : 447 - 453
  • [30] PH MEASUREMENTS IN AQUEOUS CO2 SOLUTIONS UNDER HIGH-PRESSURE AND TEMPERATURE
    CROLET, JL
    BONIS, MR
    CORROSION, 1983, 39 (02) : 39 - 46