Accurate Monte Carlo Modeling of Small-Animal Multi-Pinhole SPECT for Non-Standard Multi-Isotope Applications

被引:2
|
作者
Lukas, Mathias [1 ,2 ]
Kluge, Anne [3 ]
Beindorff, Nicola [4 ]
Brenner, Winfried [1 ,5 ]
机构
[1] Charite Univ Med Berlin, Dept Nucl Med, D-13353 Berlin, Germany
[2] Siemens Healthcare GmbH, D-13629 Berlin, Germany
[3] Charite Univ med Berlin, Dept Radiat Oncol & Radiotherapy, D-13353 Berlin, Germany
[4] Charite Univ Med Berlin, Berlin Expt Radionuclide Imaging Ctr BERIC, D-13353 Berlin, Germany
[5] Charite Univ Med Berlin, German Canc Consortium DKTK, D-13353 Berlin, Germany
关键词
Collimators; Detectors; Single photon emission computed tomography; Imaging; Monte Carlo methods; Logic gates; Head; Monte Carlo simulation; multi-isotope; multi-pinhole; SPECT; GATE; GEANT4; SIMULATION; CAPABILITIES; SIMSET; GATE;
D O I
10.1109/TMI.2021.3073749
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Recent advances in preclinical SPECT instrumentation enable non-standard multi-isotope acquisitions at the edge of physical feasibility to improve efficiency of pharmaceutical research. Due to the variety of applications, optimization of imaging hardware, acquisition protocols and reconstruction algorithms is a central and recurring task. For this purpose, we developed a Monte Carlo simulation model of a preclinical state-of-the-art multi-pinhole SPECT system, the NanoSPECT/CTPLUS, with emphasis on high accuracy for multi-isotope experiments operating near the system range limits. The GATE/ GEANT4 model included an accurate description of multi-pinhole collimators and all substructures of the detector back compartment. The readout electronics was modeled with a variety of signal processors partially extended to incorporate non-simplified measured response functions. The final model was able to predict energy spectra, planar images and tomographic reconstructions with high accuracy for both standard and non-standard multi-isotope experiments. Complex activity distributions could be reproduced for a wide range of noise levels and different modes of angular undersampling. Using the example of a dual-isotope triple-tracer experiment, the model has proven to be a powerful tool for protocol optimization and quantitative image correction at the performance range limits of multi-isotope multi-pinhole SPECT.
引用
收藏
页码:2208 / 2220
页数:13
相关论文
共 37 条
  • [1] Multi-Isotope Capabilities of a Small-Animal Multi-Pinhole SPECT System
    Lukas, Mathias
    Kluge, Anne
    Beindorff, Nicola
    Brenner, Winfried
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2020, 61 (01) : 152 - 161
  • [2] Multi-pinhole small animal SPECT
    Schramm, N
    Schurrat, T
    Béhé, M
    Lackas, C
    Hoppin, J
    Ebel, G
    Behr, TM
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S236 - S236
  • [3] Small animal imaging with multi-pinhole SPECT
    Nuyts, Johan
    Vunckx, Kathleen
    Defrise, Michel
    Vanhove, Christian
    [J]. METHODS, 2009, 48 (02) : 83 - 91
  • [4] A prototype low-energy, multi-pinhole SPECT system for small-animal imaging
    Peterson, TE
    Wilson, DW
    Barrett, HH
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2999 - 3002
  • [5] Design of a Multi-Pinhole Collimator in a Dual-Headed, Stationary, Small-Animal SPECT
    Shokouhi, S.
    Fritz, M. A.
    McDonald, B. S.
    Wilson, D. W.
    Metzler, S. D.
    Peterson, T. E.
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2399 - 2402
  • [6] Multi-pinhole SPECT for small animal research.
    Schramm, NU
    Engeland, U
    Ebel, G
    Schurrat, T
    Behe, M
    Behr, TM
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 223P - 223P
  • [7] Quantitative multi-pinhole small-animal SPECT: uniform versus non-uniform Chang attenuation correction
    Wu, C.
    de Jong, J. R.
    van Andel, H. A. Gratama
    van der Have, F.
    Vastenhouw, B.
    Laverman, P.
    Boerman, O. C.
    Dierckx, R. A. J. O.
    Beekman, F. J.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (18): : N183 - N193
  • [8] Triple and dual PET quantification of a Small-Animal Multi-Pinhole PET/SPECT/CT System
    Echegoyen, P.
    Cuenca Bandin, T.
    Ecay, M.
    Prieto, E.
    Collantes, M.
    Pareja, F.
    Simon Martinez, J.
    Penuelas, I.
    Marti-Climent, J.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S144 - S144
  • [9] Development and Validation of a Monte Carlo Simulation Tool for Multi-Pinhole SPECT
    Mok, Greta S. P.
    Du, Yong
    Wang, Yuchuan
    Frey, Eric C.
    Tsui, Benjamin M. W.
    [J]. MOLECULAR IMAGING AND BIOLOGY, 2010, 12 (03) : 295 - 304
  • [10] Development and Validation of a Monte Carlo Simulation Tool for Multi-Pinhole SPECT
    Greta S. P. Mok
    Yong Du
    Yuchuan Wang
    Eric C. Frey
    Benjamin M. W. Tsui
    [J]. Molecular Imaging and Biology, 2010, 12 : 295 - 304