Accurate Monte Carlo Modeling of Small-Animal Multi-Pinhole SPECT for Non-Standard Multi-Isotope Applications

被引:2
|
作者
Lukas, Mathias [1 ,2 ]
Kluge, Anne [3 ]
Beindorff, Nicola [4 ]
Brenner, Winfried [1 ,5 ]
机构
[1] Charite Univ Med Berlin, Dept Nucl Med, D-13353 Berlin, Germany
[2] Siemens Healthcare GmbH, D-13629 Berlin, Germany
[3] Charite Univ med Berlin, Dept Radiat Oncol & Radiotherapy, D-13353 Berlin, Germany
[4] Charite Univ Med Berlin, Berlin Expt Radionuclide Imaging Ctr BERIC, D-13353 Berlin, Germany
[5] Charite Univ Med Berlin, German Canc Consortium DKTK, D-13353 Berlin, Germany
关键词
Collimators; Detectors; Single photon emission computed tomography; Imaging; Monte Carlo methods; Logic gates; Head; Monte Carlo simulation; multi-isotope; multi-pinhole; SPECT; GATE; GEANT4; SIMULATION; CAPABILITIES; SIMSET; GATE;
D O I
10.1109/TMI.2021.3073749
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Recent advances in preclinical SPECT instrumentation enable non-standard multi-isotope acquisitions at the edge of physical feasibility to improve efficiency of pharmaceutical research. Due to the variety of applications, optimization of imaging hardware, acquisition protocols and reconstruction algorithms is a central and recurring task. For this purpose, we developed a Monte Carlo simulation model of a preclinical state-of-the-art multi-pinhole SPECT system, the NanoSPECT/CTPLUS, with emphasis on high accuracy for multi-isotope experiments operating near the system range limits. The GATE/ GEANT4 model included an accurate description of multi-pinhole collimators and all substructures of the detector back compartment. The readout electronics was modeled with a variety of signal processors partially extended to incorporate non-simplified measured response functions. The final model was able to predict energy spectra, planar images and tomographic reconstructions with high accuracy for both standard and non-standard multi-isotope experiments. Complex activity distributions could be reproduced for a wide range of noise levels and different modes of angular undersampling. Using the example of a dual-isotope triple-tracer experiment, the model has proven to be a powerful tool for protocol optimization and quantitative image correction at the performance range limits of multi-isotope multi-pinhole SPECT.
引用
收藏
页码:2208 / 2220
页数:13
相关论文
共 37 条
  • [31] Characteristics among three multi-pinhole collimators using a new small animal SPECT-PET/CT system
    Shibutani, Takayuki
    Onoguchi, Masahisa
    Kanno, Takayuki
    Ogihara, Shun
    Wakabayashi, Hiroshi
    Inaki, Anri
    Hiromasa, Tomo
    Taki, Junichi
    Shiba, Kazuhiro
    Kinuya, Seigo
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [32] Performance evaluation and quantitative accuracy of a multi-pinhole small animal SPECT/CT scanner for theranostic Lu-177 imaging
    Gupta, Arun
    Kim, Kyeong Yun
    Lee, Min Sun
    Hwang, Donghwi
    Lee, Dong Soo
    Lee, Jae Sung
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [33] A Multi-Function Compact Small-Animal Imaging System Incorporating Multipinhole Standard and Helical SPECT and Parallel-Hole SPECT
    Qian, Jianguo
    Bradley, Eric L.
    Majewski, Stan
    Popov, Vladimir
    Saha, Margaret S.
    Smith, Mark F.
    Weisenberger, Andrew G.
    Welsh, Robert E.
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2430 - 2438
  • [34] Ultra-high-resolution SPECT with CdTe for small-animal imaging applications: A Monte Carlo simulation study using a voxelized phantom
    Su-Jin Park
    Chang-Lae Lee
    Hyo-Min Cho
    Hee-Joung Kim
    [J]. Journal of the Korean Physical Society, 2012, 60 : 1145 - 1149
  • [35] Ultra-high-resolution SPECT with CdTe for Small-animal Imaging Applications: A Monte Carlo Simulation Study Using A Voxelized Phantom
    Park, Su-Jin
    Lee, Chang-Lae
    Cho, Hyo-Min
    Kim, Hee-Joung
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 60 (07) : 1145 - 1149
  • [36] Opposite brain images of Tc-99m-ECD and Tc-99m-HMPAO on rodent stroke animal model by small animal multi-pinhole SPECT
    Shih, Jun-Ming
    Huang, Yuan-Ruei
    Kang-Wei, Chang
    Chen, Chia-Chieh
    Shen, Lie-Hang
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [37] Tc-99m-ECD brain image on B6 stroke mice animal model by small animal multi-pinhole SPECT - Physical surgical operation alter BBB permeability
    Shih, Jun-Ming
    Hwang, Li-Chung
    Chen, Chia-Chien
    Shen, Lie-Hang
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2009, 50